| Plan Review Stops For Permit 04050770 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-10 |
Time |
11:58 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2004-11-10 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-10-27 |
Time |
15:47 |
Rev Time |
2.50 |
| Received By |
mjacobs |
Date |
2004-10-27 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2004-10-27 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04050770 | | | ADD:2175 PALM BEACH LAKES BLVD | | | CONT:TAYCON CONST. MANAGEMENT INC. | | | TEL: (561)622-2699 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4THREVIEW | | | ACTION:DENIED | | | | | | | | | 1) FL. BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PLEASE PROVIDE TWO COPIES | | | (3COPIES IF THRESHOLD OR RESIDENT | | | INSPECTOR) OF PROCUCT TESTING REPORTS, | | | MISSING REPORTS ARE AS FOLLOWS. | | | A) WINDOWS: PLEASE HAVE THE APPLICATION | | | PROVIDED COMPLETE BY THE MANUFACTURE | | | FOR THE WINDOWS SUBMITTED. IF NOT, YOU | | | MAY SUBMIT A STATE APPROVE WINDOW | | | PRODUCT. | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | YOU CAN ASK IF THERE IS ANY CREDIT FROM | | | THE PREVIOUS BUILDING WHICH WAS DEMO. | | | | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEW | | | TEL: (561) 805-6726 | | | FAX: (561) 659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-08-13 |
Time |
09:49 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2004-08-13 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2004-08-13 00:00:00 | 8-13-04 SUBMITTALS MJACOBS | | | FIREDOOR,LLC SWINGING (ILLEGIBLE PAGES) | | | ROOFING TILES (INDICATE FASTEN SCHEDULE) | | | SIMPSON STRONG TIE (OK) | | | BUILT-UP ROOF SYSTEM FOR STEEL DECK | | | SEE EXPIRATION DATE | | | ROOFING INSULATION FL618 (OK) | | | GLASS BLOCK WINDOW (OK) | | | PLEASE SEE FIRST REVIEW NOTES FOR | | | ADDITIONAL SUBMITTALS. | | | | | | SUBMITTALS REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-08-12 |
Time |
15:30 |
Rev Time |
4.00 |
| Received By |
mjacobs |
Date |
2004-08-12 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04050770 | | | ADD:2175 PALM BEACH LAKES BLVD | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | PLEASE SEE 1ST REVIEW #1 | | | | | | 2) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL.REPORTS NEED ORIGINAL SIGNSTURE | | | AND NEED TO SEALED. | | | SEE IST REVIEW #2. | | | | | | 3 ) FBC 13-103.1.2BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | ALSO SEE FLORIDA STATUES 481.221 AND | | | F.A.C. 61G-16.003 | | | | | | 4) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | ON ROOFING DETAILS. PRESSURES ZONE 3 | | | SEE FBC TABLE 1606.2B. ROOF ANGLE 10-30 | | | | | | 5) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS/STORE FRONT | | | B)EXTERIOR DOORS METAL/GLASS SUBMITAL | | | REPORT EXPEIRED. PROVIDE GLASS DOOR | | | REPORTS. | | | C)1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | D) FBC 1707.4.5.2 MULLIONS SHALL BE | | | DESIGNED TO TRANSFER THE DESIGN PRESSURE | | | LOAD APPLIED TO THE WINDOW OR DOOR | | | ASSEMBLIES TO THE ROUGH OPENING SUBTRATE | | | INFORMATION WAS NOT SUBMITTED. (13,14) | | | | | | 6)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE | | | USED FOR ALL NON-IMPACT GLAZING. | | | FBC. 1606.1.4. | | | | | | 8)FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | THE REFERENCE SECTION YOU GAVE ON | | | SHEET A9 IS NOT IN OUR JURISDICTION. | | | PLEASE SEE F.A.C. CH.4-13 | | | | | | 9) SHEET A-6A CANOPY PLAN. PLEASE | | | SUBMIT ENGINEERING AND STRUCTUAL | | | DRAWINGS FOR CONSTRUCTION CANOPY | | | SEE NOTE #16 FIRST REVIEW. | | | | | | 10)LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-11 |
Time |
15:48 |
Rev Time |
8.00 |
| Received By |
mjacobs |
Date |
2004-06-18 |
Time |
13:50 |
Sent To |
PC |
|
| Notes |
| 2004-06-18 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04050770 | | | ADD: 2175 PALM BEACH LAKES BLVD | | | CONT:FLORIDA GENERAL CONTRACTOR INC | | | TEL: (561)364-4988 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITEY KNOWN, OR IS IN | | | QUESTIONTHE BUILDING OFFICIAL MAY | | | REQUIRE EXPLORATIONS, TEST OR OTHER | | | ADEQUATE PROOF AS TO THE PERMISSIBLE | | | SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA.SHEET A-2 INDICATES REPORT BY | | | ARDAMEN 3/13/04 | | | | | | 3)FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 4) F102.1 WPB AMMENDMENTS, FIRE | | | DISTRICTSHEET A-1 NO TYPE VI | | | CONSTRUCTION ALLOW-ED. A) NO EXTERIOR | | | WALLS CAN BE MADE OF COMBUSTIBLE | | | MATERIALS,( PLYWOOD SHEATH- ING & WOOD | | | FRAMING MEMBERS) | | | | | | 5) FBC* F102.2.7ARCHITECTURAL TRIM, | | | ON BUILDINGS LOCATED IN THE FIRE | | | DISTRICT, SHALL BE CONSTRUCTED OF | | | APPROVED NON-COMBUSTIBLE MATERIALS OR | | | FIRE RETARDANT TREATED WOOD.ANNOTATE | | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | SEE A-5/ A-10 PECKY CYPRESS CORBOL | | | | | | 6) FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 7) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | ON ROOFING DETAILS. PLEASE INDICATE | | | WHICH DETAIL WILL BE USED AS PER SHEET | | | A-8A DETAIL #2.(PLYWOOD DECK OR METAL | | | DECK. ALSO INSULATION ATTATCHMENT) | | | | | | 8) 1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE | | | MECHANICAL EQUIPMENT, APPLIANCES AND | | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL | | | BE DESIGNED AND INSTALLED TO RESIST THE | | | WIND PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE | | | ACCOMPLISHED BY DESIGN OR BY | | | APPLICATION OF | | | SECTION 301.13.1. (NO DIMENTIONS SHOWN) | | | SHEET A-8A CONDENSING UNIT DETAIL. | | | | | | 9) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) GLASS BLOCK | | | C)MULLIONS | | | D) EXTERIOR DOORS | | | E) STORM SHUTTERS/IF IMPACT GLAZING IS | | | NOT USED, | | | F) ROOF ASSEMBLIES/CEMENT TILE/INSUL | | | MODIFIED ROOFING/90LB | | | G) TRUSS ANCHOR | | | | | | 10) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 11)PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE | | | USEDFOR ALL NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | 12) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE | | | INSTALLATIONSCHEDULE SUMMARIZING & | | | IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL | | | PRES-SURE ZONES, SLAT TYPES, ETC., | | | SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 13) 1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 14) 1707.4.5.2 MULLIONS SHALL BE | | | DESIGN-ED TO TRANSFER THE DESIGN | | | PRESSURE LOADSAPPLIED BY THE WINDOW OR | | | DOOR ASSEMBLIESTO THE ROUGH OPENING | | | SUBTRATE. | | | | | | 15) A10 DETAIL#2 SHOW MORE DETAILS FOR | | | CONNECTION TO BAR JOISTS. IF JOISTS ARE | | | FIVE FEET O.C (5'O.C) PROVIDE DOCUMENTS | | | OR REPORTS ON SPAN DISTANCE, FOR THE | | | GAUGE OFTOP TRACKBEING USED AND | | | HOW IT IS FASTENED TO THE BAR JOISTS. | | | | | | 16) SHEET A-6A CANOPY PLAN.PLEASE | | | SUBMITENGINEERING AND STRUCTUAL | | | DRAWINGS FOR | | | CONSTRUCTION OF CANOPY. | | | | | | 17) FBC 1606.1.7WIND LOAD.THE PLANS | | | SHALL STATE THE BASIC WIND SPEED, WIND | | | IMPORTANCE FACTOR, WIND EXPOSURE | | | CATEGORY, AND EXTERIOR COMPONENT | | | AND CLADDING DESIGN WIND PRESSURES.ALSO | | | PLEASE SPECIFY THE TYPE OF BOLTS AND | | | ANCHORS TO USED ON COSTRUCTION OF CANOPY | | | | | | 18) F102.2.11 EXTERIOR PLASTIC VENEER IS | | | NOT PERMITTED IN THE FIRE DISTRICT. | | | PLEASE AMEND PLANS. | | | | | | | | | | | | NF |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-26 |
Time |
10:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-10-26 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-16 |
Time |
15:34 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-16 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2004-08-16 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE PANEL "B" IS STILL | | | SHOWN W/ 20A OCP AND #12 TO A PANEL | | | SHOWN WITH A 71A LOAD?? | | | PLEASE SEE THIS WAS ON ORIGINAL NOTES. | | | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM INDICAT | | | -ES EQUIPMENT GROUNDING CONDUCTORS | | | INSTALLED BEFORE AND AFTER FIRST MEANS | | | OF DISCONNETC. EQUIPMENT GRNDS ARE ONLY | | | PERMITTED AFTER THE FIRST MEANS OF DISC. | | | 250.6,250.24 | | | PLEASE ADJUST RISER. | | | | | | 3)NOTE: PLEASE SEE A-17 WHICH CONTAINS | | | A TITLE BLOCK FOR "COBURN & ASSC INC". | | | PLEASE SEE THE ELECTRICAL PLANS DO NOT | | | CONTAIN THIS SAME TITLE BLOCK FROM | | | CONBURN & ASSC? FS 553.79 PE REQUIRED. | | | PLEASE ALSO SEE FAC 61G15-23.002, WHICH | | | ALSO REQUIRES TO HAVE THE PRINTED NAME | | | AND LICENSE #(PE) INCLUDED IN TITLE | | | BLOCK. | | | | | | 4)NOTE: PLEASE SEE RISER INDICATES A | | | PANEL CW AND NO PANEL SCHEDULE WAS | | | SUBMITTED.? | | | | | | 5 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | LOAD SHOWN APPEARS TO BE CONNECTED LOAD? | | | | | | PLEASE SEE POSSILE COMMENTS FROM OTHER | | | REVIEWERS THAT MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-02 |
Time |
07:30 |
Rev Time |
2.00 |
| Received By |
jleahy |
Date |
2004-06-02 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | 1) NEED TO SHOW CLASS LOCATIONS ON A | | | SITE PLAN, PER 500.4 OF THE NEC | | | | | | 2) PUMPS NOT SHOWN ON DRAWINGS FOR | | | LOCATION | | | | | | 3) SHOW LOCATION OF EMERGENCY SWITCH | | | | | | 4) RISER SHOWS #12 FEEDING PANEL "B" | | | PANEL "B" HAS A LOAD OF 44 AMPERES? | | | | | | 5) NEED EQUIPMENT SCHEDULE FOR FAST FOOD | | | AREA, THIS LOOKS LIKE A KITCHEN IF SO | | | SHOW GFCI PROTECTION FOR ALL 125V | | | 15,20ACIRCUITS. | | | | | | 6) GAS PUMP PANEL WHICH ONE ON THE | | | RISERIS IT????? | | | | | | 7) CAR WASH IS A WET LOCATION NEED TO | | | NOTE ABOUT 1/4" OF AIR SPACE BETWEEN | | | WALLSAND EQUIPMENT. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-08-30 |
Time |
09:11 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-08-13 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2004-08-30 00:00:00 | PASSED WITH PROVISOS: | | | 1. PLEASE SUBMIT CALCULATION FOR | | | PERVIOUS, IMPERVIOUS AND BUILDING AREA. | | | 2. SHEET 2 OF 6 SHOWS 750 GAL. GREASE/ | | | WATER SEPARATOR IN SEWER LINE FROM THE | | | PROPOSED CAR WASH, THIS SHOULD BE OIL/ | | | WATER SEPARATOR. | | | 3. POLLUTION/ EROSION PLANS MUST BE | | | INSTALLED PRIOR TO BEGINNING ANY WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-05-21 |
Time |
08:51 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-05-21 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | FAILED: | | | 1. CIVIL PLANS MUST BE APPROVED BY THE | | | PUBLIC UTILITIES & ENGINEERING FOR ALL | | | THE CONNECTIONS FOR SERVICES AND FOR THE | | | LOCATION OF METERS, BACKFLOWS, ETC. | | | PROIR TO CONSTRUCTION SERVICES'S | | | APPROVAL, 659-8040 ATT: MANNY GONZALEZ | | | 2. PLEASE SUBMIT CALCULATIONS FOR THE | | | PROPOSED STORM WATER TO US OR TO STEVE | | | SARLEY AT PUBLIC UTILITIES & ENGINNERING | | | ,HOWEVER PERVIOUS , IMPERVIOUS, BUILDING | | | AREA CALCULATION FOR THE ENTIRE SITE, | | | SIGNED & SEALED MUST BE SUBMITED TO US. | | | 3. WORK WITHIN PUBLIC R.O.W REQUIRES | | | APPROVAL AND SEPARATE PERMIT FROM PB | | | COUNTY AND CITY ENGINEER'S OFFICE PROIR | | | TO BEGIN WORK. | | | 4. PLEASE NOTE THAT SITE PLAN HAS NOT | | | BEEN APPROVED BY THE PLANNING & ZONING. | | | 5. SHOW DIMENSIONS FOR THE DUMPSTER | | | ENCLOSURE, IF TO BE PICKED UP BY THE | | | CITY, 12'-6" OPENING BETWEEN GATE POSTS | | | AND 12'-0" DEEP.DETAILS ON SHEET A-12 | | | ARCHITECTURAL MUST BE REVISED. | | | 6. PLEASE VERIFY, 150 GALLON OIL/WATER | | | SEPARATOR AS SHOWN ON SEWER LINE FROM | | | THE CONVENIENCE STORE, SHOULD THIS BE A | | | GREASE/ WATER SEPARATOR? | | | 7. PLEASE CONTACT RODNEY COMPO AT | | | 837-4051 EXT. 4074 REGARDING THE SIZE, | | | LOCATION INSTALLATION, INSPECTION AND | | | SHOP DRAWING REQUIREMENTS FOR THE | | | PROPOSED OIL,GREASE / WATER SEPARATORS, | | | NOTE TO G.C. | | | 8. SIGNS AND MARKINGS SHOULD BE SHOWN ON | | | CIVIL PLANS. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-10-14 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-10-14 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-08-13 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-08-13 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2004-08-13 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR UNDERGROUND FUEL TANKS. PLANS | | | ARE TO BE SUBMITTED TO PBC DERM FOR | | | STAMPING PRIOR TO SUBMITTING TO | | | CITY. | | | | | | 2) DOOR # 1 TO HAVE SIGNAGE 1" LETTERS | | | "DOORS TO REMAIN UNLOCKED DURING | | | BUSINESS HOURS". | | | | | | 3) EMERGENCY SWITCHES NOTE ON PAGE | | | A-17 NEEDS TO BE FINALIZED. | | | | | | 4) PLEASE INDICATE LOCATIONS OF | | | WARNING SIGNS AND WORDING FOR THESE | | | SIGNS AT THE FUEL DISPENSERS. | | | | | | 5) PLEASE INDICATE FIRE EXTINGUISHER | | | LOCATIONS AT FUELING AREA. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-25 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-25 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | 1) ALL DEMOLITION, RENOVATION AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3) THE PLANS INDICATE TYPE VI | | | CONSTRUCTION. TYPE VI CONSTRUCTION IS | | | NOT ALLOWED IN THE CITY FIRE LIMITS. | | | PLEASE SEE APPENDIX F, LOCAL AMENDMENTS | | | TO THE FLORIDA BUILDING CODE. PLEASE | | | AMEND THE PLANS. | | | | | | 4) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWING. A MINIMUM OF 6" | | | HIGH NUMBERS IS REQUIRED. | | | | | | 5) WOOD SHOWN ON PLANS. FIRE RATED | | | WOOD IS ALLOWED IN THE CITY FIRE LIMTS. | | | | | | 6) PLEASE INDICATE INTERIOR FINISH | | | FOR WALLS AND CEILINGS. | | | | | | 7) EFIS NOTED ON CANOPY. ALL | | | ARCHITECTURAL TRIM LOCATED IN THE | | | FIRE LIMITS SHALL BE NONCOMBUSTIBLE. | | | | | | 8) PLEASE INDICATE ALL WARNING SIGNS | | | AND OTHER SAFETY EQUIPMENT PLANNED FOR | | | THE FUEL DISPENSING PUMPS. | | | | | | 9) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FUEL TANK INSTALLATIONS. | | | | | | 10) PLEASE INDICATE LOCATIONS OF ALL | | | PORTABLE FIRE EXTINGUISHERS. | | | | | | 11) FUEL TANKS TO COMPLY WITH NFPA 30A. | | | | | | 12) STATION TO COMPLY WITH NFPA 30A. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
10:01 |
Sent To |
B |
|
| Notes |
| 2005-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
16:34 |
Sent To |
I |
|
| Notes |
| 2005-09-21 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-08-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-08-29 |
Time |
09:22 |
Sent To |
P |
|
| Notes |
| 2005-09-01 00:00:00 | REVISON/TCO | | | SENT TO PLUMB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-11 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-11 |
Time |
10:44 |
Sent To |
M |
|
| Notes |
| 2005-05-11 00:00:00 | TO "PKRAUSS" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
16:34 |
Sent To |
B |
|
| Notes |
| 2004-11-05 00:00:00 | TO MJ DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2004-10-27 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2004-10-27 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2004-10-27 00:00:00 | SUBMITTAL GIVEN TO KEN STEVENS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-11 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-11 |
Time |
15:48 |
Sent To |
B |
|
| Notes |
| 2004-08-11 00:00:00 | TO MJ DESK/SUBMITTALS PA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2004-08-03 00:00:00 | TO COMM BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-02 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-05-18 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2004-05-18 00:00:00 | TO COMM BD#17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-22 |
Time |
11:06 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-09-22 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-01 |
Time |
06:59 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-06-01 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | DENIED: | | | SEPARATE MECHANICAL PERMIT AND FEES | | | REQUIRED FOR THE WALK-IN COOLER PERMIT. | | | SEE COMMENTS DATED 10-14-04. | | | | | | IF YOU HAVE ANY QUESITSONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-14 |
Time |
11:46 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-10-14 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2004-10-14 00:00:00 | ADDITIONAL PERMITS REQUIRED FOR THE | | | FUEL TANKS/PIPING AND WALK-IN COOLERS. | | | UNDERGROUND FUEL TANKS APPROVED BY | | | DERM, CHIP GREENE.PLEASE PROVIDE | | | MANUFACTURER CUT SHEETS FOR THE WALK-IN | | | COOLERS WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
06:54 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-08-26 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2004-08-26 00:00:00 | DENIED: | | | 1. PLEASE PROVIDE ORIGINAL PERMIT WITH | | | RESUBMITTAL. | | | | | | 2. PLANS FOR THE REMOVAL OR INSTALLATION | | | OF FUEL TANKS SHALL HAVE PRIOR APPROVAL | | | BY PBC DERM.SEE PREVIOUS COMMENTS FOR | | | ADDRESS AND POINT OF CONTACT. | | | | | | 3.ADDITIONAL PERMIT REQUIRED FOR FUEL | | | TANKS & WALK IN COOLERS.CUT SHEETS ON | | | THE COOLER PROVIDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-08 |
Time |
09:55 |
Rev Time |
1.25 |
| Received By |
pkrauss |
Date |
2004-06-08 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2004-06-08 00:00:00 | DENIED: | | | 1.ENERGY CALCULATIONS INDICATE MAXIMUM | | | TONNAGE AS 6 TONS.PLAN SHEET A-15 | | | THE EQUIPMENT SCHEDULE INDICATES A TOTAL | | | OF 11 TONS. | | | | | | 2.ADDITIONAL PERMIT REQUIRED FOR THE | | | WALK-IN COOLER/FREEZERS.PROVIDE | | | MANUFACTURER SUBMITTAL DATA WITH PERMIT | | | APPLICATION. | | | | | | 3.PLAN SHEET A-6 INDICATES THE TOP OF | | | THE JOISTS AS 16' 4".PER 2001 FBC(M) | | | 306.5, EQUIPMENT LOCATED ON ROOFS AT A | | | HEIGHT GREATER THAN 16' SHALL HAVE A | | | PERMANENT MEANS OF ACCESS.SUCH ACCESS | | | SHALL NOT REQUIRE CLIMBING OVER OBJECTS | | | GREATER THAN 30". | | | | | | 4.PLAN SHEET A-8A, DETAIL FOR THE | | | CONDENSING UNIT.HEIGHT REQUIREMENT FOR | | | THE C.U. STAND SHALL COMPLY WITH 2001 | | | FBC 1511.7 (SEE ATTACHED SCHEDULE). | | | | | | 5.INDICATE TERMINATION OF THE | | | CONDENSATE. | | | | | | 6.ADDITIONAL PERMIT REQUIRED FOR THE | | | UNDERGROUND FUEL TANKS, PLANS TO HAVE | | | PRIOR APPROVAL FROM PALM BEACH COUNTY | | | DERM AT 3323 BELVEDERE RD BUILD #502. | | | ATTENTION CHIP GREEN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-10-12 |
Time |
09:07 |
Rev Time |
0.55 |
| Received By |
kstevens |
Date |
2005-10-12 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2005-10-12 00:00:00 | REVISION OK ADDED AN OIL SEPARATOR TO | | | PLANS, CHANGED 2 FLOOR SINKS TO FLOOR | | | DRAINS. NO INDIRECT WASTE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-21 |
Time |
09:19 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-09-21 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2005-09-21 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTPER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS A-13 & A-14 FLOOR DRAINS ARE NOT | | | AN APPROVED INDIRECT WASTE RECEPTOR. | | | SECTIONS 802.3 & 802.3.2. A FLOOR SINK | | | OR A HUB DRAIN IS REQUIRED FOR INDIRECT | | | WASTE. | | | 2. SHTS A-13 & A-14 THE PERSONAL | | | SIGNATURE IS REQUIRED ON THE SEAL PER | | | FAC 61G1-16.003 & FAC 61G1-16.004(5). | | | INITIALS ARE NOT APPROVED. FS 481.2055. | | | 3. SHT A-13 FLOOR DRAIN IN TOILET ROOM | | | IS NOT VENTED AS SHOWN. SEE RED LINE | | | CORRECTION ON PLANS FOR THE CORRECT | | | CONNECTION OF W/C TO BUILDING DRAIN. | | | THIS WAS RED LINED ON ISSUED SET OF | | | PLANS AND SHALL BE CORRECTED ON | | | REVISION. SECTIONS 901.2.1 & 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-08 |
Time |
10:11 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-11-08 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-08-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-21 |
Time |
06:57 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-08-20 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2004-08-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHTS A-1 & A-2, SHT A-1 SHOWS A PRO- | | | POSED 750 GAL SAND/OIL INTERCEPTOR, | | | WHEREAS SHT A-2 SHOWS A 158 GAL INTECEP- | | | TOR. PLEASE CORRELATE PLANS/DETAILS. | | | SECTION 104.2.1 | | | 2) FROM PREVIOUS REVIEW: ROUTE PLANS TO | | | DBPR HOTEL AND RESTURANT DIVISION. RES- | | | PONSE NOTED BUT UNABLE TO FIND INFORMAT- | | | ION FROM RESPONSE. PLEASE CLARIFY. SECT- | | | ION 104.2.1 | | | 3) FROM PREVIOUS REVIEW: SHT A-3 WATER | | | FILTERS SHALL COMPLY WITH NSF-42. MANUF. | | | INFORMATION IS NOT CLEAR AND HARD TO | | | READ, AND DOES NOT INDICATE COMPLIANCE | | | WITH NSF-42. PLEASE SUBMIT MANUF. INFOR- | | | MATION SHOWING THAT FILTERS COMPLY WITH | | | NSF-42. SECTION 611.1 | | | 4) FROM PREVIOUS REVIEW: SUBMIT PLANS | | | FOR CAR WASH. NO RESPONSE NOTED. SECTION | | | 1-4.2.1 & 104.3.1.1 | | | 5) SHT A-1 REFERS TO CIVIL PLANS. CIVIL | | | PLANS ARE NOT SUBMITTED. PLEASE SUBMIT | | | A SET OF CIVIL PLANS TO CORRELATE INFOR- | | | MATION REQUIRED TO APPROVE PLANS. SECT- | | | ION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-05 |
Time |
13:51 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2004-06-05 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2004-06-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) CONTACT RODNEY COMPO, ENVIRONMENTAL | | | MANAGER FOR SIZING OF GREASE INTERCEPTOR | | | AND OIL/SAND INTERCEPTOR. WASET ORDINAN- | | | CE 2938-96. (561) 837-4074. | | | 2) ROUTE PLANS TO DBPR HOTEL AND RESTUR- | | | AND DIVISION FOR REVIEW PRIOR TO RESUB- | | | MITTING FOR REVIEW AT CITY WPB. PLANS | | | SHALL BE STAMPED AND WORKSHEETS ATTACHED | | | TO EACH SET OF PLANS FOR REVIEW. SECTION | | | 101.4.7 | | | 3) SHT A-3 SHOW CLEAR FLOOR SPACE FOR | | | FIXTURES IN WOMENS TOILET ROOM. SECTIONS | | | 11-4.16.2 AND 11-4.19.3. | | | 4) SHT A-3 WATER FILTERS SHALL COMPLY | | | WITH NSF-42. SUBMIT MANUF. SPECIFICATION | | | SHEETS. SECTION 611.1 | | | 5) SEPARATE PERMITS ARE REQUIRED FOR: | | | - GREASE INTERCEPTORS | | | - OIL/SAND INTERCEPTORS | | | - IRRIGATION | | | - CAR WASH SYSTEM - SUBMIT PLANS. | | | 6) SHT A-13 THE CODE IN EFFECT IS FBC- | | | 2001 PLUMBING. PLUMBING NOTES REFERES | | | TO STANDARD CODE. PLEASE CHANGE REFEREN- | | | CE. SECTION 104.2.1 | | | 7) RPZ BACKFLOW IS REQUIRED FOR WATER | | | SERVICE TO THE CAR WASH. SEC 608.13.2 | | | 8) SHT A-14 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN (FLAT LAYOUT | | | ON SHT A-13) NOR DOES IT MEET CODE REQ- | | | UIREMENTS. | | | A) A-13 SHOWS ALL FLOOR SINKS ON THE | | | GREASE LINE. - RISER SHOWS SOME F.S. ON | | | THE SANT. LINE. | | | B) A FLOOR DRAIN AND A FLOOR SINK ARE | | | MISSING ON THE RISER DIAGRAM. | | | C) THERE IS A HORIZONTAL DRY VENT AFTER | | | THE LAST FLOOR SINK ON THE GREASE LINE. | | | THIS FLOOR SINK SHOULD BE CONNECTED ON | | | THE VERTICAL RISE OF THE VENT. SECTION | | | 905.3 | | | D) FLOOR DRAIN IN MENS TOILET ROOM IS | | | LABLED AS A FLOOR SINK ON THE RISER DIA- | | | GRAM. | | | E) LAV ARMS AND TRAP ARE NOT SHOWN ON | | | THE RISER DIAGRAM. | | | F) HAND SINK VENT IS SHOWN AS A 3" ON | | | A-13 AND 2" ON THE RISER DIAGRAM. | | | PLEASE CORRELATE PLANS. SECTION 104.2.1 | | | 9) THE PERSONAL SIGNATURE OF THE ARCHIT- | | | ECT SHALL APPEAR ON ALL ARCHITECTURAL | | | DOCUMENTS TO BE FILED FOR PUBLIC RECORD. | | | DOCUMENTS SHALL BE SIGNED PERSONALLY AND | | | SEALED/DATED BY THE RESPONSIBLE ARCHITE- | | | CT. INITIALS ARE NOT APPROVED. IF THISIS | | | YOUR LEGAL SIGNATURE, A COPY OF DRIVERS | | | LICENSE, VOTERS REGISTRATION, OR ARCHIT- | | | ECTS LICENSE SHOWING LEGAL SIGNATURE | | | WITH A NOTARIZED LETTER STATING THAT IS | | | YOUR LEGAL SIGNATURE FOR OUR FILE WILL | | | SUFFICE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-02 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-02 |
Time |
16:21 |
Sent To |
I |
|
| Notes |
| 2004-06-02 00:00:00 | APPROVED BY JOSH LONG, PLANNER 659-8031 |
|
|