| Plan Review Stops For Permit 04050734 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-06 |
Time |
08:57 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
2004-07-06 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | BUTT GLASS ENGINEERING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-01 |
Time |
16:21 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-06-29 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | PROVISO: | | | | | | BUTT GLASS ASSEMBLY: | | | SUBMIT ENGINEERING (SIGNED & SEALED) ON | | | THE BUTT GLASS ASSEMBLY.INCLUDE A | | | LETTER FROM THE ENGINEER STATING HE | | | WILL PERFORM AN ONSITE INSPECTION OF | | | THE WINDOWS WHEN IT HAS BEEN INSTALLED | | | TO VERIFY IT HAS BEEN INSTALLED PER HIS | | | ENGINEERING. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-28 |
Time |
19:38 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-06-02 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALMBEACH COUNTY.THE ACTUAL PERMIT | | | PLANS | | | MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO | | | THE PERMIT APPLICATION.PLEASE CALL | | | (561) 233-5025 FOR MORE INFORMATION. | | | | | | 2. SUBMIT THE ENGINEERING FOR THE BUTT | | | GLASS ASSEMBLY INCLUDING MFGRS. SPECS | | | ON SILICONE GEL BEING USED.THE | | | ENGINEER MUST INSPECT THE UNIT WHEN | | | INSTALLED AND PROVIDE A SIGNED & SEALED | | | LETTER STATING IT IS INSTALLED PER HIS | | | SPECIFICATIONS. PRODUCT APPROVALS ARE | | | ALSO REQUIRED. | | | | | | 3. HIGHLIGHT THE MIAMI/DADE PRODUCT | | | APPROVALS FOR THE FIXED WINDOWS SHOWING | | | SIZE AND SHAPE BEING INSTALLED. | | | | | | 4. THE DESIGN PRESSURES OF THE GARAGE | | | DOORS AS STATED ON THE PLANS DO NOT | | | MATCH THE PRODUCT APPROVALS.PLEASE | | | CORRECT. | | | | | | 5. SEE NOTES FROM ELECTRIC REGARDING | | | THE ARCHITECT TITLE BLOCK AND SIGNATURE | | | REQUIREMENTS PER FS 481.221 | | | | | | 6. HIGHLIGHT THE TYPE OF CEMENT TILE | | | BEING INSTALLED ON THE PRODUCT | | | APPROVALS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-23 |
Time |
06:00 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-02-23 |
Time |
06:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-01 |
Time |
08:32 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-01 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2005-02-01 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE AN EQUIPMENT | | | GROUNDING CONDUCTOR IS SHOWN FROM METER | | | TO MAIN/PANEL "B". PLEASE SEE | | | 250.6,250.24. EQP GRND IS ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISC. | | | | | | 2)NOTE: PLEASE SEE | | | 210.11C1,210.52B,220.16, SMALL APPL IS | | | 1.5 KW MIN, PLEASE ALSO SEE DINING RM | | | RQ'D RECEPTS. | | | | | | 3)NOTE: PLEASE SEE 5KW SHOWN ON 1P20A | | | BRKR FOR GOLF CART CHARGER. | | | PLEASE SEE 3KW ON 1P20A BATH GFI | | | CIRCUIT. | | | PLEASE ADJUST. | | | LOADS EXCEED RATINGS OF CIRCUITS. | | | 240.4 ETC. | | | | | | 4)NOTE:PLEASE SEE MAIN BRKR PANEL "B", | | | IS SHOWN AS 8-16 CIRCUIT PANEL YET, | | | PANEL "B" IS SHOWN ASA 42 CIRCUIT | | | PANEL ON PANEL SCHEDULE. | | | | | | 5)NOTE: PLEASE SHOW PANEL "C" ON PLANS. | | | COULD NOT LOCATE THIS ON PLANS. | | | | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
07:36 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
07:36 |
Sent To |
P |
|
| Notes |
| 2004-06-17 00:00:00 | PLANS ARE REQUIRED TO HAVE ALL OLD/ | | | VOIDED SHEETS REMOVED AND NEW SHEETS TO | | | BE INSERTED. | | | | | | ELEC STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
14:56 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-19 |
Time |
18:46 |
Sent To |
M |
|
| Notes |
| 2004-05-19 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: PLEAS INDICATE GFI/GFI PROTECT- | | | -ION JACUZZI TUB. 680 | | | | | | 2)NOTE: PLEASE SEE AN EQUIPMENT GROUND- | | | -ING CONDUCTOR IS SHOWN FROM METER TO | | | DISC "B". PLEASE SEE 250.6/250.24 | | | | | | 3)NOTE: PLEASE SEE 210.52C1 FOR MISSING | | | RECEPTS ON KITCHEN COUNTERSPACE. | | | | | | 4)NOTE: PLEASE SEE 210.63 FOR MISSING | | | GFI RECEPT FOR A/C COND UNITS. | | | | | | 5)NOTE: PLEASE SEE SEE RAISED SEAL MUST | | | BE CLEAR AND VISABLE WITH ALL INFORMAT- | | | -ION. PLEASE ALSO SEE FS 481.221, WHICH | | | REQ'S A COMPLETE SIGNATURE. FIRST NAME | | | IS SHOWN AS AN INITIAL. PLEASE ALSO | | | SIGN FIRST NAME. PER DBPR. | | | THIS IS REQ'D ON ALL PLANS WEATHER OR | | | NOT COMMENT IS MADE BY OTHER REVIEWERS. | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 7)NOTE: PLEASE SEE ONE PANEL IS SHOWN | | | IN GARAGE, PLEASE INDICATE LOCATION OF | | | OTHER PANEL. | | | | | | 8)NOTE: PLEASE SEE SD IS REQ'D TO BE | | | MOVED INTO MASTER BEDRM. NFPA-72 | | | 8-1 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-18 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
14:13 |
Sent To |
E |
|
| Notes |
| 2005-02-18 00:00:00 | TO DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
14:13 |
Sent To |
E |
|
| Notes |
| 2005-01-31 00:00:00 | TO "DP" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-01 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-01 |
Time |
16:21 |
Sent To |
B |
|
| Notes |
| 2004-07-01 00:00:00 | TO LS DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-14 |
Time |
14:55 |
Sent To |
E |
|
| Notes |
| 2004-06-14 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-18 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-05-18 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | TO SFD RACK/E | | 2004-05-18 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-19 |
Time |
18:46 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-05-28 |
Time |
11:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-28 |
Time |
19:38 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-06-28 |
Time |
19:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
07:37 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-05-29 |
Time |
06:39 |
Sent To |
B |
|
| Notes |
| 2004-05-29 00:00:00 | DENIED; | | | RAISED SEAL IS NOT CLEAR. | | | COMPLETE SIGNITURE IS REQUIRED. | | | ONLY ONE COPY OF RISER DIAGRAM FOUND. | | | PLEASE ATTACH TO PLANS AND VOID OUT | | | OLD RISER DIAGRAM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-18 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-18 |
Time |
17:45 |
Sent To |
I |
|
| Notes |
|
|