| Plan Review Stops For Permit 04050697 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-07-19 |
Time |
09:05 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2004-07-19 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-15 |
Time |
12:38 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-06-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04050697 | | | ADD: 600 NORTHPOINT PKWY | | | (PHASE V 2ND FL GUEST ROOMS | | | CORRIDOR & VENDING) WEST | | | CONT: AMERICAN BUILDING INTERIORS | | | TEL: (239)542-5717 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 2) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | 3) SHOW THE MEANS OF EGRESS WITH IN | | | THE UNIT, DOUBLE/ DOUBLE SUITE, KING | | | SUITE. QUEEN/ QUEEN CONNECTOR HAS ONLY | | | 30" BETWEEN THE DRESSER AND THE CORNER | | | OF THE WALL. SEE TABLE 1004, 36" MINIMUM | | | CLEAR WIDTH. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-09 |
Time |
15:16 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-09 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-19 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2004-05-19 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-29 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-29 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-30 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-30 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2004-06-30 00:00:00 | TO COMM BD#56/5 OF 8 PERMITS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-30 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | TO COMM BD#6/5 OF 8 PERMITS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-02 |
Time |
09:38 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2004-06-02 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | NO MECHANICAL PLAN SUBMITTED.PERMIT | | | APPLICATION INDICATES NOT APPLICABLE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-31 |
Time |
09:01 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-07-31 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-20 |
Time |
13:47 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-07-20 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | | | | SEE REVIEW COMMENT PERMIT #04050693 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-05 |
Time |
09:44 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-06-05 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2004-06-05 00:00:00 | SEE REVIEW COMMENTS FROM PERMIT NUMBER | | | 04050693. KSTEVENS |
|
|