| Plan Review Stops For Permit 04050693 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-07-19 |
Time |
09:01 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-07-19 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-15 |
Time |
10:09 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-06-15 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04050693 | | | ADD: 600 NORTHPOINT PKWY | | | (PHASE 1) 3RD FL GUEST ROOMS | | | CORRIDOR & VENDING | | | CONT: AMERICAN BUILDING INTERIORS | | | TEL: (239)542-5717 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 2) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | 3) SHOW EXIT MEANS OF EGRESS WITHIN | | | THE UNITS, DOUBLE/DOUBLE SUITE, KING | | | SUITE. QUEEN/QUEEN CONNECTOR HAS ONLY | | | 30" BETWEEN THE DRESSER AND CORNER OF | | | WALL. SEE TABLE 1004 36" MINIMUM CLEAR | | | WIDTH. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-09 |
Time |
15:09 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-07-09 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-19 |
Time |
11:51 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-05-19 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | ******** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEEFAC 61G1-16.004, | | | A TITLE BLOCK REQ'D FOR EACH SHEET AND | | | ALL INFORMATION AS SETFORTH UNDER FAC | | | AND FS 481.219. | | | | | | 2)NOTE: PLEASE SEE ELECTRICAL SEEMS | | | TO BE MIXED IN WITH ARCH PLANS.?? | | | PLEASE SHOW CIRCUITING ON PLANS AND | | | CORRELATE WITH PANEL SCHEDULE. ? | | | | | | PLEASE CLARIFY DEVICE HEIGHTS FOR | | | FHAR 24 CFR 100.205 | | | | | | PLEASE SEE 210.62/ 210.52 FOR RECEPT | | | SPACING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-29 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-29 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-19 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-19 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | 1) DURING THE PHASING OPERATION, ALL | | | EXIT DOORS SHALL REMAIN CLEAR AND | | | ACCESSIBLE. | | | | | | 2) NO BLOCKING OF ANY EXIT ACCESS, EXIT, | | | OR EXIT DISCHARGE SHALL OCCUR. | | | | | | 3) ANY DEBRIS SHALL BE REMOVED FROM | | | THE SITE DAILY. | | | | | | 4) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION SHALL COMPLY WITH NFPA 241. | | | | | | 5) NO UNAUTHORIZED CUTTING AND WELDING | | | OPERATIONS SHALL BE PERFORMED. | | | | | | 6) ALL REQUIRED FIRE AND LIFE SAFETY | | | SYSTEMS SHALL REMAIN OPERATIONAL AT | | | ALL TIMES. | | | | | | 7) ANY USE OF FUEL POWERED EQUIPMENT | | | MUST BE PROVIDED WITH PROPER | | | VETILATION TO PREVENT THE ACCUMULATION | | | OF CARBON MONOXIDE VAPORS. | | | | | | 8) WHAT SAEFGUARDS WILL BE TAKEN TO | | | SEPARATE CONSTRUCTION FROM NON | | | CONSTRUCTION AREAS. | | | | | | 9) NON FIRE RATED VISQUEEN SHALL NOT | | | BE AFFIXED TO ANY WALLS OR CEILINGS. | | | | | | 10) PLEASE REVIEW FURNITURE LOBBY PLAN. | | | IT APPEARS THAT TO MUCH FURNITURE MAY | | | BE PRESENT. | | | | | | 11) PLEASE PROVIDE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR ALL NEW | | | HANDRAILS. | | | | | | 12) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR NEW FIRE ALARM EQUIPMENT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-30 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-30 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2004-06-30 00:00:00 | TO COMM BD#56/1 OF 8 PERMITS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-15 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-05-17 |
Time |
15:19 |
Sent To |
PC |
|
| Notes |
| 2004-05-17 00:00:00 | TO COMM BD#6/1 0F 8 PERMITS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-02 |
Time |
09:34 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-06-02 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | PERMIT APPLICATION INDICATES NOT | | | APPLICABLE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-31 |
Time |
08:53 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2004-07-31 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-20 |
Time |
13:22 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-07-20 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: PER SECTION | | | 11-9.2.3 (CHAPTER 509 FS) 1 UNIT REQUIR- | | | ED TO COMPLY WITH ITEMS (1)(2)(3) - PRO- | | | VIDE DETAILS/ROOM NUMBER. - RESPONSE | | | NOTED, BUT ANY FRACTION ABOVE A WHOLE | | | NUMBER SHALL BE ROUNDED UP TO A WHOLE | | | NUMBER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-05 |
Time |
06:12 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2004-06-05 |
Time |
06:12 |
Sent To |
|
|
| Notes |
| 2004-06-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) PER SECTION 11-9.2.3 (CHAPTER 509 FS) | | | 1 UNIT REQUIRED TO COMPLY WITH ITEMS | | | (1)(2)(3) - PROVIDE DETAILS AND ROOM | | | NUMBER. | | | 2) PER SECTION 11-9.1.3, 5 ROOMS IN ADD- | | | ITION TO THOSE REQUIRED TO BE ACCESSIBLE | | | SHALL BE PROVIDED WITH VISUAL ALARMS, | | | NOTIFICATION DEFICES, AND TELEPHONE FOR | | | PERSONS WITH HEARING IMPAIRMENTS. PLEASE | | | PROVIDE INFORMATION, DETAILS, AND ROOM | | | NUMBERS TO SHOW COMPLIANCE. | | | 3) PER SECTION 11-9.1.4, SLEEPING ROOMS | | | AND SUITES REQUIRED TO BE ACCESSIBLE BY | | | 11-9.1.2 SHALL BE DISPERSED AMONG THE | | | VARIOUS CLASSES OF SLEEPING ACCOMODAT- | | | IONS AVAILABLE TO PATRONS OF THE PLACE | | | OF TRANSIENT LODGING. PLANS INDICATE | | | THAT NO ACCESSIBLE ROOMS OR SUITES ARE | | | AVAILABLE FOR THE KING CONNECTOR, QUEEN/ | | | QUEEN OR THE QUEEN/QUEEN CONNECTOR. | | | PLEASE CLARIFY. | | | 4) SHTS L101 & L305 DETAIL 11-10D - RE- | | | MOVAL OF DRINKING FOUNTAIN, MINIMUM FAC- | | | ILITIES REQUIRES A DRINKING FOUNTAIN PER | | | TABLE 403.1. WILL THE DRINKING FOUNTAIN | | | BE REPLACED/RELOCATED? IS THERE ANOTHER | | | DRINKING FOUNTAIN AVAILABLE? PLEASE | | | CLARIFY. | | | 5) SHT L101 ITEM 11-17D - IN THE REMOVAL | | | OF ANY PART OF A DRAINAGE SYSTEM, DEAD | | | ENDS SHALL BE PROHIBITED. (OVER 2 FEET) | | | SECTION 704.5. | | | 6) MORE INFORMATION REQUIRED ON TITLE | | | BLOCK FOR ARCHITECT. SEE FAC 61G1-16.004 | | | AND FS 481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|