| Plan Review Stops For Permit 04050613 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-24 |
Time |
10:48 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-06-24 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-03 |
Time |
15:41 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2004-06-03 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04050613 | | | ADD: 1200 S FLAGLER DR# 1504 | | | CONT: FOWLER BUILDING CO | | | TEL: (772)486-5350 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | A) PROVIDE THE HEIGHT OF THE BUILDING. | | | B) THE LOCATION OF SLIDING GLASS DOORS | | | TO BE REPLACED, INTERIOR ZONES OR | | | END ZONES. | | | C)PROVIDE THE DOOR SIZES TO BE INSTALLED | | | D) PROVIDE THE POSITIVE AND NEGATIVE | | | PRESSURES FOR THE DOOR OPENINGS. | | | E) HIGH-LIGHT THE TYPE OF ANCHOR AND | | | SPACING TO BE USED. | | | | | | 2) NOTE: TYPE I OR II BUILDINGS, 609.2.1 | | | PARTITIONS ARE TO BE CONSTRUCTED FROM | | | NONCOMBUSTIBLE MATERIALS.THIS INCLUDES | | | BLOCKING OR BACKING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-29 |
Time |
10:42 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2004-06-29 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | 1) SUBMIT NEW RISER DIAGRAM BEFORE FINAL | | | | | | 2) SUBMIT NEW PANEL SCHEDULE(S) | | | | | | SUBMIT ALL NEW INFORMATION BEFORE FINAL | | | INSPECTIONJAKE LEAHY805-6740 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-29 |
Time |
08:39 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2004-06-29 |
Time |
08:32 |
Sent To |
P |
|
| Notes |
| 2004-06-29 00:00:00 | 1) PLANS ARE NOT CLEAR AS TO WHAT IS NEW | | | AND WHAT IS EXISTING. | | | | | | 2) PANEL SCHEDULE DOES NOT SHOW ALL NEW | | | LOADS. | | | | | | 3) SHOW LOCATION OF NEW PANEL | | | | | | 4) SHOW PANEL SCHEDULE FOR NEW PANEL | | | | | | 5) ON THE PANEL SHEDULES SHOW ARC FAULT | | | AND GFI ON SCHEDULE. ALSO SHOW ROOM | | | SUCHAS BATHROOM GFI, BEDROOM ARC FAULT | | | | | | 6) SHOW ALL NEW WORK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
14:55 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-14 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2004-06-14 00:00:00 | *********** UNSAT ***************** | | | | | | PLEASE SEE NOW AN ELECTRICAL PLAN/DRAW- | | | -ING IS BEING SUBMITTED ALONG WITH A | | | DESCIPTION OF WORK. | | | | | | 1)NOTE: PLEASE SUBMIT A PANEL SCHEDULE | | | TO INCLUDE NEW AND EXISTING. PLEASE SHOW | | | LOAD CALC WITH NEW LOADS BEING ADDED. | | | PLEASE SHOW SIZE OF EXSITNG PANEL/SERV- | | | -ICE. PLEASE ALSO SHOW LOCATION OF PANEL | | | 215.5/220 | | | | | | 2)NOTE: PLEASE LIST BATH CIRCUITS PER | | | 210.11C3/ 20A #12. | | | | | | 3)NOTE; PLEASE SEE NFPA-72 8-1 | | | SD'S ARE REQUIRED TO INSIDE AND OUTSIDE | | | SLEEPING RMS AND REQUIRED TO BE WIRED | | | INLINE. | | | PLEASE ALSO SEE UNDER THE 2002 NEC THE | | | SD'S IN BEDRMS MUST BE ARC FAULT PROTECT | | | -ED. 210.12 | | | | | | 4)NOTE: PLANS NOW SHOW A NEW STEAM UNIT | | | BEING ADDED. PLEASE SEE DUE TO COMBUST- | | | -ABLES, STEAM UNIT MAY NOT BE LOCATED | | | IN CLOTHES CLOSET. | | | PLEASE PROVIDE SPECS FOR UNIT AND | | | INFORMATION FOR CLEARENCE. | | | PLEASE PROVIDE LOAD ON LOAD CALCS ALSO. | | | | | | 5)NOTE: PLEASE SEE NEW LT BEING ADDED | | | TO CLOSET/STORAGE? PLEASE SEE 410.8 FOR | | | MIN FIXRURE TYPE AND MIN CLEARENCE | | | REQ'D. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-17 |
Time |
16:41 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-17 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | ** UNSAT ** | | | | | | 1)NOTE: PLEASE SHOW LOCATIONS OF DEVICES | | | TO BE INSTALLED NEW AND /OR REPLACED. | | | PLEASE ALSO SEE 104.2.1, PLANS/DRAWINGS | | | REQ'D TO HAVE A PRINTED NAME AND SIGNAT- | | | -URE OF PERSON RESPONSIBLE FOR PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-21 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-21 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
14:55 |
Sent To |
E |
|
| Notes |
| 2004-06-25 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-10 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-10 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | TO COMM BD#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-17 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | TO COMM BD#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-22 |
Time |
15:19 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-06-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2004-06-22 00:00:00 | RE-ROUTE DUCT WORK TO ACCOMMODATE FOR | | | THE NEW RAISED CEILING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-06-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-01 |
Time |
08:10 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-06-01 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2004-06-01 00:00:00 | PROVIDE AS BUILT PLANS PRIOR TO | | | INSPECTION.INDICATE DUCT/GRILLE SIZE, | | | MATERIAL AND LAYOUT.INDICATE NEW & | | | EXISTING DUCTWORK AND EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-29 |
Time |
10:27 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-06-22 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2004-06-22 00:00:00 | NO PLUMBING PLANS SUBMITTED - MINIMUM | | | 2" TRAP AND DRAIN FOR SHOWERS. TABLE | | | 709.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-04 |
Time |
18:05 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-06-04 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2004-06-04 00:00:00 | NO PLUMBING PLANS SUBMITTED - 2" DRAIN | | | REQUIRED FOR SHOWER. TABLE 709.1 | | | FIELD INSPECTOR SHALL VERIFY ALL CONDIT- | | | IONS. |
|
|