| Plan Review Stops For Permit 04050579 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-06 |
Time |
07:59 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-08-06 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-05 |
Time |
17:28 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-07-19 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | SEE PLUMBING & ELECTRICAL NOTES ON | | | SIGNATURES. LS | | 2004-07-13 00:00:00 | SENT TO DP DESK | | 2004-05-28 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. NOTICE OF COMMENCEMNT IS NOT FILED | | | WITH THE COUNTY CLERK OFFICE. | | | | | | 2. VALUE ON PROPOSAL IS TOO LOW PER | | | MARSHALL AND SWIFT. (SEE PLUMBING NOTES) | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-05 |
Time |
17:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-05 |
Time |
17:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-05 |
Time |
15:36 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-26 |
Time |
09:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
14:25 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-15 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2004-07-15 00:00:00 | **** UNSAT *** | | | ELECTRICAL SUBMITTAL BROUGHT IN MUST BE | | | RESUBBED WITH CORRECTIONS ON PLANS AND | | | AFTER PLANS HAVE GONE THROUGH ALL REVIEW | | | -S. | | | | | | DEWEY PALMER | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-06 |
Time |
13:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-06 |
Time |
13:27 |
Sent To |
P |
|
| Notes |
| 2004-07-06 00:00:00 | *********** UNSAT 2ND TIME *********** | | | | | | 1)NOTE: PLEASE CORRELATE AND SHOW ALL | | | ELECTRICAL AND POOL EQUIPMENT ON PLUMB | | | SCH AND ELECTRICAL DIAGRAM. | | | PLEASE INCLUDE CONDUCTOR SIZES ETC. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE/LOAD | | | CALCS NOW SUBMITTED. PLEASE SEE THESE | | | SHEETS ARE SEALED COPIES AND DO NOT | | | CONTAIN ORIGINAL SIGNATURE AS REQUIRED | | | UNDER FS 481.221/471.023. | | | PLEASE ALSO INCLUDE ALL INFORMATION ON | | | TITLE BLOCK AS REQUIRED PER FS 481.219, | | | FAC 61G1-16.004. | | | LICENSE #'S/FIRM # ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-30 |
Time |
13:40 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-18 |
Time |
18:29 |
Sent To |
P |
|
| Notes |
| 2004-05-18 00:00:00 | ********* UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE SPEC SHEET SUBMITTED | | | IS FOR A GAS HEATER?? | | | | | | 2)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | FOR EXISTING ELECTRICAL SERVICE. | | | THIS IS TO INCLUDE ALL NEW AND EXSITING | | | LOADS. | | | PLEASE SEE ALL MOTOR LOADS ARE AT 100% | | | AND 125% FOR CONTINUOUS LOADS. (3OR MORE | | | HRS).HEAT PUMP INCLUDED. | | | LARGEST MOTOR AT 125%. | | | 215.3,230.42,220.19 ETC. | | | | | | 3)NOTE: PLEASE CORRELATE EQUIPMENT | | | SCHEDULE/PLUMB RISER AND WIRING DIAGRAM. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-18 |
Time |
15:15 |
Sent To |
P |
|
| Notes |
| 2004-10-18 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2004-07-22 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-30 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-30 |
Time |
13:40 |
Sent To |
E |
|
| Notes |
| 2004-06-30 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-18 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-18 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-18 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-14 |
Time |
08:37 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
|
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-11-02 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2004-11-02 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2004-11-02 00:00:00 | REWVISION: | | | DELETE 1-1/2PIT LINE. | | | REMANING PIT LINES 2". |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
15:15 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-08-02 |
Time |
15:22 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-26 |
Time |
09:30 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-16 |
Time |
16:26 |
Sent To |
B |
|
| Notes |
| 2004-07-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | A) FROM PREVIOUS REVIEW: | | | 2) GAS POOL HEATER INDICATED IN PROPOSAL | | | IS NOT SHOWN ON EQUIPMENT LAYOUT. THE | | | POOL SPECIFICATIONS ALSO DO NOT SHOW THE | | | THE GAS POOL HEATER. PLEASE CORRELATE | | | PLANS WITH INFORMATION SHOWN ON THE PRO- | | | POSAL. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-06 |
Time |
13:27 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-05-27 |
Time |
18:50 |
Sent To |
B |
|
| Notes |
| 2004-05-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | WPB CITY CODE | | | | | | 1) 104.6.5 BUILDING PERMIT VALUATION. IF | | | IN THE OPINION OF THE BUILDING OFFICIAL | | | THE CLAIMED VALUATION OF BUILDING, AL- | | | TERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, | | | THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED ESTIMATES | | | AND/OR BONA FIDED SIGNED CONTRACTS (EX- | | | CLUDING LAND VALUE) TO MEET THE APPROVAL | | | OF THE BUILDING OFFICIAL. FOR PERMITTING | | | PURPOSES, VALUATION FOR BUILDINGS AND | | | SYSTEMS SHALL BE FOUND IN MARSHALL AND | | | SWIFT OR THE SOUTHERN BUILDING CODE | | | CONGRESS INTERNATIONAL VALUATION TABLES, | | | LATEST EDITION, AND SHALL BE BASED ON | | | TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHAN- | | | ICAL, INTERIOR FINISH, NORMAL SITE WORK | | | (EXCAVATION AND BACKFILL FOR BUILDINGS), | | | ARCHITECTURAL AND DESIGN FEES, OVERHEAD | | | AND PROFIT, EXCLUDING ONLY LAND VALUE. | | | - A QUICK LOOK AT MARSHALL & SWIFT INDI- | | | CATES THAT THE POOL W/EXTRA LIGHT, EXTRA | | | PUMPS, SPA, AND JANDY SYSTEM SHALL COST | | | $36,650 AND THIS IS NOT INCLUDING THE | | | VANISHING EDGE, COLUMNS WITH ROSETTE | | | PIPING & ROSETTES, POOL ALARMS, CAST | | | STONE, EXTRA MAIN DRAINS (5), PIT FOR | | | VANISHING EDGE, 400, BTU GAS POOL HEATER | | | EXTRA POOL RETURNS, AIR BLOWER ECT. | | | - SUBMIT A VALUATION FOR THE POOL & SPA | | | WITH ALL EXTRAS AND PRICED PER MARSHALL | | | & SWIFT OR SBCCI VALUATION TABLES PER | | | SECTION 104.6.5. | | | 2) GAS POOL HEATER INDICATED IN PROPOSAL | | | IS NOT SHOWN ON EQUIPMENT LAYOUT. ALSO | | | NEED MANUF. SPECIFICATION SHEETS FOR THE | | | POOL HEATER. SECTION 424.2.14.1 AND | | | SECTION 424.2.14.2. | | | 3) INFORMATIONAL: PER CITY CODE 2853-95 | | | SECTION 31-31 A BACKFLOW WILL BE INSTALL | | | ED BY A CERTIFIED PLUMBER AND TESTED BY | | | THE CITY BEFORE A PERMIT WILL BE ISSUED | | | FOR THE POOL CONSTRUCTION. (SEE ATTACHED | | | SHEET). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-14 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-18 |
Time |
10:30 |
Sent To |
I |
|
| Notes |
|
|