Plan Review Details - Permit 04050410
| Plan Review Stops For Permit 04050410 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-07-26 |
Time |
13:29 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-07-26 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | BUILDING PROVISO: | | | NEW HALLWAY DOORS TO MEET MANEUVERING | | | CLEARENCES AT DOORWAYS. 4-13.6. 18"ON | | | THE PULL SIDE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-14 |
Time |
12:38 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-05-14 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 04050410 | | | ADD: 1818 S AUSTRALIAN AV | | | CONT: RIENDEAU CONSTRUCTION | | | TEL: (561)722-5850 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)1004.1.4 WHERE 2 OR MORE EXITS OR | | | EXIT ACCESS DOORS ARE REQUIED, AT LEAST | | | 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL | | | BE PLACED A DISTANCE APART EQUAL TO NOT | | | LESS THAN 1/2 OF THE LENGTH OF THE MAX- | | | IMUM OVERALL DIAGONAL DIMENSION OF THE | | | BUILDING OR AREA TO BE SERVED. | | | | | | 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 4) PROVIDE INFORMATION ON THE FIRE RAT- | | | ING OF THE ENTRY DOORS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-23 |
Time |
08:12 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-23 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2004-07-23 00:00:00 | REDLINED 700.12E. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
08:08 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-13 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL CIRCUITING | | | ON PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE TO BE SUBMITTED. | | | PLEASE ALSO SEE 700.12E FOR EMLTS. | | | | | | 2)NOTE: PLEASE INDICATE CONTROL(S) FOR | | | LIGHTING. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-28 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-28 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-14 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-14 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER AND FIRE ALARM | | | SYSTEM. | | | | | | 2) NO FIRE ALARM EQUIPMENT SHOWN | | | WITHIN TENANT SPACE. PLEASE ADVISE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-19 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | TO COMM BD#20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-11 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | TO COMM BD#7 |
|
|
|