| Plan Review Stops For Permit 04050406 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-14 |
Time |
15:08 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-07-14 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
19:26 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-05-24 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | SEPARATE PERMIT REQUIRED FOR ROOF WITH | | | FLORIDA PRODUCT APPROVALS. | | | | | | SEE ELECTRICAL & PLUMBING COMMENTS ON | | | LICENSING & SEALS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
10:19 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-12 |
Time |
10:19 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-08 |
Time |
09:37 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
19:57 |
Sent To |
P |
|
| Notes |
| 2004-07-01 00:00:00 | ********* UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE TITLE BLOCK REQUIRES | | | LICENSE # FOR ARCH AND/OR FIRM SHOWN | | | IN NOTES AS METRO DESIGN GROUP. | | | FS 481.219,61G1-16.004 | | | | | | ELECTRICAL PLANS STAMPED IN ERROR, | | | PLEASE RE-PRINT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | 2004-06-17 00:00:00 | SENT TO PLUMB, NEW SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-17 |
Time |
08:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-14 |
Time |
06:18 |
Sent To |
P |
|
| Notes |
| 2004-05-14 00:00:00 | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE METER COMBO SHOWN AS | | | MLO WITH NO MAIN?? PLEASE INDICATE MCB | | | OR MAIN DISC. | | | | | | 2)NOTE: PLEASE SEE MAIN HOUSE IS ALSO | | | SHOWN AS MLO? PLEASE SEE 225.31 FOR | | | DETACHED BLDGS. | | | | | | 3)NOTE: PLEASE CIRCUITS/NOTE IN GARAGE | | | INDICATES NEW ELEC TO HOUSE PANEL?? | | | THESE WOULD COME FROM M/M COMBO? | | | PLEASE PROVIDE PANEL SCHEDULES AND LOAD | | | CALCS. 215.5 | | | | | | 4)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM GARAGE TO MAIN | | | HOUSE. 250.32, 250.122 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-08 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-08 |
Time |
09:37 |
Sent To |
E |
|
| Notes |
| 2004-07-08 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-17 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-17 |
Time |
08:22 |
Sent To |
E |
|
| Notes |
| 2004-06-17 00:00:00 | SENT TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-16 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-15 |
Time |
16:42 |
Sent To |
Z |
|
| Notes |
| 2004-06-15 00:00:00 | 6-14-04 RESUB RETURN TO CONTR. BROUGHT | | | BACK 6-15-04 FIRST RESUB. MJ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-14 |
Time |
16:17 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-13 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-13 |
Time |
14:10 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-13 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-11 |
Time |
16:54 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-05-16 |
Time |
12:58 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-05-24 |
Time |
12:04 |
Sent To |
B |
|
| Notes |
| 2004-05-24 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. | | | PLEASE NOTE, 100 CFM OF OUTSIDE AIR | | | REQUIRED FOR THE GARAGE AREA.THIS | | | CAN BE ACCOMPLISHED BY NATURAL MEANS AS | | | DICTATED IN 2001 FBC(M) 402.2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
19:26 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-07-13 |
Time |
19:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
10:20 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-07-01 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2004-07-01 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FIRM LICENSE NUMBER REQUIRED ON TITLE | | | BLOCK OF EACH SHEET. FAC 61G1-16.004(2) | | | FS 481.2055 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
19:57 |
Rev Time |
0.60 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-16 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-16 |
Time |
12:44 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-15 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-13 |
Time |
11:11 |
Sent To |
I |
|
| Notes |
| 2004-05-13 00:00:00 | DENIED, NEED SURVEY WITH DIMENSION OF | | | LOT WITH SETBACKS. CALLED CONTR MM |
|
|