Plan Review Details - Permit 04050406
Plan Review Stops For Permit 04050406
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-14 Cont ID  
Sent By lsmith Date 2004-07-14 Time 15:08 Rev Time 0.75
Received By lsmith Date 2004-07-14 Time 15:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-01 Cont ID  
Sent By jleech Date 2004-07-13 Time 19:26 Rev Time 1.00
Received By lsmith Date 2004-05-24 Time 14:18 Sent To  
Notes
2004-05-24 00:00:00SEPARATE PERMIT REQUIRED FOR ROOF WITH
 FLORIDA PRODUCT APPROVALS.
  
 SEE ELECTRICAL & PLUMBING COMMENTS ON
 LICENSING & SEALS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-07-12 Cont ID  
Sent By dpalmer Date 2004-07-12 Time 10:19 Rev Time 0.25
Received By dpalmer Date 2004-07-12 Time 10:19 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-08 Time 09:37 Rev Time 0.25
Received By dpalmer Date 2004-06-17 Time 19:57 Sent To P
Notes
2004-07-01 00:00:00********* UNSAT *************
  
 1)NOTE: PLEASE SEE TITLE BLOCK REQUIRES
 LICENSE # FOR ARCH AND/OR FIRM SHOWN
 IN NOTES AS METRO DESIGN GROUP.
 FS 481.219,61G1-16.004
  
 ELECTRICAL PLANS STAMPED IN ERROR,
 PLEASE RE-PRINT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
2004-06-17 00:00:00SENT TO PLUMB, NEW SHEETS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-14 Cont ID  
Sent By mjacobs Date 2004-06-17 Time 08:23 Rev Time 0.33
Received By dpalmer Date 2004-05-14 Time 06:18 Sent To P
Notes
2004-05-14 00:00:00********** UNSAT ************
  
 1)NOTE: PLEASE SEE METER COMBO SHOWN AS
 MLO WITH NO MAIN?? PLEASE INDICATE MCB
 OR MAIN DISC.
  
 2)NOTE: PLEASE SEE MAIN HOUSE IS ALSO
 SHOWN AS MLO? PLEASE SEE 225.31 FOR
 DETACHED BLDGS.
  
 3)NOTE: PLEASE CIRCUITS/NOTE IN GARAGE
 INDICATES NEW ELEC TO HOUSE PANEL??
 THESE WOULD COME FROM M/M COMBO?
 PLEASE PROVIDE PANEL SCHEDULES AND LOAD
 CALCS. 215.5
  
 4)NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM GARAGE TO MAIN
 HOUSE. 250.32, 250.122
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-07-08 Cont ID  
Sent By csiegber Date 2004-07-08 Time 09:37 Rev Time 0.00
Received By csiegber Date 2004-07-08 Time 09:37 Sent To E
Notes
2004-07-08 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-17 Cont ID  
Sent By mjacobs Date 2004-06-17 Time 08:23 Rev Time 0.00
Received By mjacobs Date 2004-06-17 Time 08:22 Sent To E
Notes
2004-06-17 00:00:00SENT TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-06-15 Cont ID  
Sent By mmclean Date 2004-06-16 Time 12:44 Rev Time 0.00
Received By mjacobs Date 2004-06-15 Time 16:42 Sent To Z
Notes
2004-06-15 00:00:006-14-04 RESUB RETURN TO CONTR. BROUGHT
 BACK 6-15-04 FIRST RESUB. MJ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-14 Cont ID  
Sent By mjacobs Date 2004-06-14 Time 16:18 Rev Time 0.00
Received By mjacobs Date 2004-06-14 Time 16:17 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-13 Time 14:10 Rev Time 0.00
Received By csiegber Date 2004-05-13 Time 14:10 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-11 Cont ID  
Sent By mmclean Date 2004-05-13 Time 11:11 Rev Time 0.00
Received By csiegber Date 2004-05-11 Time 16:54 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-05-24 Cont ID  
Sent By pschmitz Date 2004-05-16 Time 12:58 Rev Time 0.25
Received By pkrauss Date 2004-05-24 Time 12:04 Sent To B
Notes
2004-05-24 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH PERMIT APPLICATION.
 PLEASE NOTE, 100 CFM OF OUTSIDE AIR
 REQUIRED FOR THE GARAGE AREA.THIS
 CAN BE ACCOMPLISHED BY NATURAL MEANS AS
 DICTATED IN 2001 FBC(M) 402.2.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-07-13 Cont ID  
Sent By jleech Date 2004-07-13 Time 19:26 Rev Time 0.25
Received By jleech Date 2004-07-13 Time 19:26 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-07-01 Cont ID  
Sent By dpalmer Date 2004-07-12 Time 10:20 Rev Time 0.25
Received By kstevens Date 2004-07-01 Time 14:56 Sent To  
Notes
2004-07-01 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FIRM LICENSE NUMBER REQUIRED ON TITLE
 BLOCK OF EACH SHEET. FAC 61G1-16.004(2)
 FS 481.2055
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-16 Cont ID  
Sent By dpalmer Date 2004-06-17 Time 19:57 Rev Time 0.60
Received By pschmitz Date   Time   Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-06-16 Cont ID  
Sent By mmclean Date 2004-06-16 Time 12:44 Rev Time 0.00
Received By mmclean Date 2004-06-16 Time 12:44 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-05-13 Cont ID  
Sent By mjacobs Date 2004-06-15 Time 16:42 Rev Time 0.00
Received By mmclean Date 2004-05-13 Time 11:11 Sent To I
Notes
2004-05-13 00:00:00DENIED, NEED SURVEY WITH DIMENSION OF
 LOT WITH SETBACKS. CALLED CONTR MM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved