| Plan Review Stops For Permit 04050289 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-14 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-14 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2004-09-14 00:00:00 | SAME NOTES AS PREVIOUS REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-30 |
Time |
15:58 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-07-19 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | PROVISO | | | | | | APPLY FOR STORM PANELS UNDER A SEPARATE | | | PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-15 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-07-13 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2004-07-13 00:00:00 | SENT TO DP DESK | | 2004-06-09 00:00:00 | DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) THE MAXIMUM HEIGHT ALLOWED FOR THE | | | GARDEN WALL IS SIX FEET ABOVE FINAL | | | GRADE. PLEASE CORRECT DETAIL ON SHEET 8. | | | | | | 3) CITY OF WPB AMENDMENTS TO FBC TABLE | | | 2306.1 REQUIRES ROOF SHEATHING NAIL | | | SPACING TO BE 4"OC AT EDGES AND 6"OC | | | INTERMEDIATE. PLEASE REVISE NOTES ON | | | SHEET 8. | | | | | | 4) THE BUTT GLASS HEADER DETAIL ON 8 IS | | | NOT APPLICABLE. PLEASE REMOVE OR CROSS | | | OFF. | | | | | | 5) WEATHERGUARD STORM PANELS DO NOT HAVE | | | STATE PRODUCT APPROVAL. SUBMIT STORM | | | PANELS WITH STATE OR LOCAL PRODUCT | | | APPROVAL. THE KEY PLAN DOES NOT INDICATE | | | THE IMPACT WINDOW FOR EGRESS IN THE DEN. | | | INDICATE THE MOUNT TYPE AND FASTENERS | | | BY HIGHLIGHTING OR CIRCLING THEM ON THE | | | INSTALLATION DRAWINGS. | | | | | | 6) TRUSS DRWINGS ARE NOT REQUIRED TO BE | | | SUMITTED FOR PLAN REVIEW. THEY ARE | | | REQUIRED TO BE GIVEN TO THE INSPECTOR IN | | | THE FIELD AT THE TRUSS INSPECTION. | | | - THE TRUSSES ARE REQUIRED TO HAVE A | | | BOTTOM CORD LIVE LOAD OF 10PSF OR 30PSF. | | | - THE CENTER BEARING POINT OF TRUSS FG-4 | | | HAS AN UPLIFT VALUE GREATER THAN THE ONE | | | GIVEN ON THE PLAN. PLEASE CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-30 |
Time |
15:58 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-30 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2004-08-30 00:00:00 | LTR FROM ARCH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-14 |
Time |
17:53 |
Sent To |
M |
|
| Notes |
| 2004-07-14 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE PREVIOUS COMMENTS. | | | PLEASE SEE A COPY ARCH'S CARD LICENSE | | | HAS BEEN SUBMITTED TO REFER TO LEGAL | | | SIGNATURE. | | | IF SIGNATURE ON PLANS WHICHS SHOWS AN | | | INITIAL FOR FIRST NAME IS INDEED ARCH'S | | | LEGAL SIGNATURE. PLEASE SUBMITA LETTER | | | WITH REFERENCE TO THIS BEING YOU FULL | | | AND LEGAL SIGNATURE. THIS LETTER MUST BE | | | SIGNED , DATED AND SEALED. | | | THIS LETTER MUST ALSO BE NOTARIZED WITH | | | REFERENCE TO ALL INFORMATION AS SET | | | FORTH FOR NOTARIES. | | | PLEASE KNOW, THIS LETTER WILL BE PLACED | | | IN OUR SIGNATURE FILE FOR FUTURE REFER- | | | -ENCE. | | | THIS IS FOR THE PROTECTION OF THE ARCH- | | | -ITECT DUE TO OTHER SITUATIONS WHERE | | | WE HAVE HAD DIRECT FORGERIES SUBMITTED. | | | THIS IS BEING REQUESTED OF ALL ARCH AND | | | ENGINEERS. | | | A RESUBMITTAL FEE WILL NOT BE ACCESSED. | | | LETTER MAY BE A SUBMITTAL. | | | IF NOT FULL LEGAL SIGNATURE, PLEASE HAVE | | | SHEETS SIGNED WITH FULL FIRST NAME ALSO | | | AS DONE ON PREVIOUS PLANS. | | | | | | 2)NOTE: PLEASE SEE THAT ALL OLD/VOIDED | | | SHEETS BE REMOVED AND NEW SHEETS ARE | | | INSERTED INTO COMPLETED SETS FOR REVIEW | | | AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-12 |
Time |
09:20 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-12 |
Time |
09:20 |
Sent To |
M |
|
| Notes |
| 2004-05-12 00:00:00 | *** UNSAT ***** | | | | | | 1 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | THIS CAN BE A PROVISO BEFORE ROUGH DUE | | | TO THE UNKNOWN # OF FIXTURES BEING | | | INSTALLED AT THIS TIME. | | | | | | 2)NOTE: PLEASE HAVE ARCH ALSO SIGN | | | PLANS WITH FIRST NAME. FS 481.221 | | | DBPR/ FBPE'S INITIALS ARE NOT PERMITTED. | | | | | | | | | PLEASE SUBMIT THE ABOVE. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-30 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2004-08-30 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-10 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-05-07 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | TO SFD RACK/E | | 2004-05-07 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-02 |
Time |
15:27 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-12-02 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-15 |
Time |
16:23 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-07-15 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-14 |
Time |
18:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-05-27 |
Time |
11:37 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-27 |
Time |
11:46 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-05-29 |
Time |
08:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-10 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-10 |
Time |
10:23 |
Sent To |
I |
|
| Notes |
|
|