| Plan Review Stops For Permit 04050206 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-10-27 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-27 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2004-10-27 00:00:00 | REVISED FRENCH DOORS, MULLIONS, CASEMENT | | | AND FIXED WINDOWS TO IMPACT RESISTANT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-17 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | REVISION TO BEAMS ON SHEETS A5 AND A6 | | | ARE OKRM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-05 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2004-08-05 00:00:00 | BUILDING PROVISO | | | | | | 1) SUBMIT STATE OR LOCAL PRODUCT | | | APPROVAL FOR THE ARCHED TOP FIBERGLASS | | | FRONT DOOR FOR APPROVAL BEFORE IT IS | | | INSTALLED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-04 |
Time |
15:20 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-06-07 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2004-06-07 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT AN ADDITIONAL COPY OF THE | | | SURVEY. | | | | | | 4) SOME OF THE SET BACK DIMENSIONS ON | | | THE SITE PLAN ON A1 DO NOT CORRESPOND | | | WITH THE SURVEY. PLEASE CORRECT. | | | | | | 5) SPECIFY THE REQUIRED SOIL BEARING | | | CAPACITY FOR THE STRUCTURE ON THE PLANS. | | | | | | 6) THE SOIL REPORT REQUIRES FOOTINGS TO | | | BE NOT LESS THAN 18" BELOW ADJACENT | | | GRADE. SOME OF THE FOOTINGS WILL NOT | | | MEET THIS REQUIREMENT. PLEASE CORRECT. | | | | | | 7) THE FULL BATH ON THE FIRST FLOOR IS | | | REQUIRED TO HAVE DOORS WITH A 29" CLEAR | | | OPENING. SEE FBC CHAPTER 11. | | | | | | 8) THE WINDOWS IN THE BATHROOMS THAT ARE | | | WITHIN 3 FEET HORIZONTALLY OF A TUB OR | | | SHOWER ARE REQUIRED TO HAVE SAFETY | | | GLAZING. SEE FBC 2405.2. | | | | | | 9) THE ID MARK FOR THE FRONT DOOR IS | | | INCORRECT ON SHEET A3. | | | | | | 10) PROVIDE A DETAIL/SECTION OF THE | | | COLUMNS AT THE BALCONY TO WHICH THE | | | GUARDRAILS ATTACH. | | | | | | 11) SPECIFY THE LOCATION OF THE CONTIN- | | | OUS 2" SOFFIT SCREEN VENTS ON THE WALL | | | SECTIONS. | | | | | | 12) THE STUDY IS REQUIRED TO HAVE EGRESS | | | WINDOWS AS REQUIRED BY FBC 1005.4 OR | | | INDICATE ON PLAN THAT THIS ROOM NOT TO | | | BE USED FOR SLEEPING PURPOSES. | | | | | | 13) SUBMIT STATE/LOCAL PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | - CUSTOM FRONT DOOR | | | - STRUCTURAL MULLIONS | | | - FRENCH DOOR WITH SIDELITES (MASTER BR) | | | - TRUSS CONNECTORS | | | | | | 14) REVISE THE DOOR SCHEDULE TO REFLECT | | | THE FIBERGLASS DOOR PRODUCT APPROVAL | | | THAT WAS SUBMITTED. | | | | | | 15) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE MOUNT TYPE AND FASTENERS THAT WILL | | | BE USED BY HIGHLIGHTING OR CIRCLING THE | | | APPROPRIATE ITEMS ON THE NOA. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2005-05-26 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-19 |
Time |
07:03 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-05-19 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2005-05-19 00:00:00 | ********** UNSAT ************ | | | | | | PLEASE SEE NOTES FROM PREVIOUS REVIEW | | | WHICH STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #3 NO, PLEASE CORRELATE | | | RISER WITH PANEL SCHEDULES SUBMITTED. | | | PLEASE SEE PANEL SCHEDULE FOR M/M COMBO | | | NOW SHOWS M/M AS 125A'SRISER SHOWS AS | | | 400A'S. A 400A MCB WOULD BE REQUIRED. | | | PLEASE SEE M/M COMBO SCHEDULE STILL DOES | | | NOT INCLUDE THE 2-200A BRKRS FOR SUB | | | PANELS AS SHOWN ON RISER. | | | PLEASE SEE PANEL "B", THIS PANEL NOTES, | | | FEED THRU LUGS TO "PANEL B"? PLEASE | | | CLARIFY HOW THIS IS POSSIBLE IF RISER | | | SHOWS (2) 200A BRKRS TO FEED EACH SUB | | | PANEL? | | | PLEASE SEE SEC'S ARE STILL BEING SHOWN | | | AS 2/0'S. PLEASE SEE MIN SIZING PER | | | 310.15B6 FOR A SF RESIDENCE. | | | PLEASE SEE RISER ALSO INDICATES "FEED | | | THRU" LUGS??? FOR ?? | | | | | | 2)NOTE: PLEASE SEE REVISED CALCULATIONS | | | FOR EACH PANEL STILL NOT SUBMITTED. | | | PLEASE ALSO SEE REVISED CALCULATIONS FOR | | | SERVICE.? PLEASE SEE A/C LOAD NOTES 65%, | | | HOWEVER 65% OF 20KW AAS SHOWN DOES NOT | | | COME OUT TO 16250KW'S? IS THERE | | | ADDITIONAL A/C LOAD? | | | PLEASE SEE 220.31 | | | | | | PLEASE SEE OTHER NOTES WERE ADDRESSED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. ONCE AGAIN, IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE TO | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-11 |
Time |
10:46 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-05-11 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2005-05-11 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE 424.3B FOR MIN OCP | | | FOR 10KW HEATSTRIPS. | | | 125% MIN. | | | | | | 2)NOTE: PLEASE SEE PLANS MISSING RECEPT | | | FOR WHIRLPOOL TUB. | | | PLEASE ALSO SEE WP IS SHOWN AS 1-POLE | | | 10A? BRKR W/2KW LOAD? | | | 240.24,310.16 ETC. | | | | | | 3)NOTE: PLEASE CORRELATE PLANS , RISER | | | DIAGRAM AND PANEL SCHEDULES. | | | PLEASE SEE RISER SHOWS 200A DISC W/ 200A | | | FUSES ON A 400A METER/MAIN COMBO? | | | PLEASE SEE PLANS SHOW PANELS A AND B | | | INSIDE GARAGE AND A METER AND A MAIN | | | OUTSIDE? | | | PLEASE SEE METER/MAIN COMBO SHOWS ONLY | | | TWO BRKRS FOR A/C CU AND POOL EQUIPMENT. | | | PLEASE SEE POOL EQUIPMENT IS ACTUALLY A | | | POOL PANEL. PLEASE SHOW POOL PANEL ON | | | PLANS, RISER AND SUBMIT PANEL SCHEDULE | | | FOR POOL PANEL. | | | | | | *** PLEASE NOTE: METER/MAIN COMBO SHALL | | | NOT HAVE MORE THAN 6 MIANS, OR 6 SPACES | | | FOR MAINS. 230.70,230.71 ETC.*** | | | | | | 4)NOTE: PLEASE SEE NO REVISED LOAD | | | CALCULATIONS WERE SUBMITTED EXCEPT FOR | | | PANEL "C"? PLEASE CORRELATE LOAD | | | CALCAULTIONS WITH PANEL SCHEDULES. | | | 220.31, 215.5 | | | | | | PLEASE SEE TWO ITEMS REDLINED ON | | | ORIGINAL PLANS NOT CORRECTED. | | | | | | 1)NOTE: PLEASE SEE LOGGIA AREA IN REAR | | | OF HOUSE WILL REQUIRE A MIN OF ONE | | | FIXTURE FOR MEANS OF EGRESS LIGHTING. | | | 210.70, LS 101 5-8. | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT FOR 2' | | | OF WALL SPACE IN STUDIO. 210.52 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
19:32 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2004-07-12 |
Time |
18:43 |
Sent To |
P |
|
| Notes |
| 2004-07-12 00:00:00 | REDLINED/ NO NEED FOR REVISION OR CORREC | | | -TION. | | | RECEPT 210.52 | | | LT FIXTURE OF SOME TYPE REQUIRED FOR | | | MEANS OF EGRESS TO REAR LOGGIA. 210.70 | | | LS101 5-8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-09 |
Time |
16:32 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-05-12 |
Time |
07:42 |
Sent To |
M |
|
| Notes |
| 2004-05-12 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004, FS | | | 481.219. PLEASE INCLUDE ALL LICENSE #'S | | | ON TITLE BLOCKS. | | | PLEASE ALSO PROVIDETHE FOLLOWING | | | FOR VERIFICATION OF "LEGAL" SIGNATURE. | | | COPY OF LICENSE, OR SIGNED AND SEALED/ | | | NOTORIZED LETTER.EITHER WILL BE PLACED | | | IN FILE FOOR FUTURE VERIFICATION. | | | PLEASE SEE FS 481.221, A "SIGNATURE" | | | IS REQ'D CONTAINING A MIN OF FIRST AND | | | LAST NAME. DBPR/ FBPE, INITIALS ARE NOT | | | PERMITTED. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 3)NOTE: PLEASE SEE NFPA-72 8-1.4.2 | | | 3' FROM BATHS/KITCHENS. SD'S W/IN 20' | | | OF COOKING APPLIANCES ETC. | | | | | | 4) NOTE: PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6`,12` RULE. | | | ONE OD THE BEDRMS | | | | | | 5)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | | ON PLANS. | | | | | | 6)NOTE: PLEASE SEE MISSING RECEPT FOR | | | KITCHEN COUNTERSPACE. 12" | | | | | | 7 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:57 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-18 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-18 |
Time |
13:34 |
Sent To |
E |
|
| Notes |
| 2005-05-18 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-09 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-09 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
| 2005-05-09 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-19 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-19 |
Time |
15:19 |
Sent To |
M |
|
| Notes |
| 2005-01-19 00:00:00 | TO "M/AC" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
| 2004-10-25 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-15 |
Time |
15:23 |
Sent To |
B |
|
| Notes |
| 2004-09-15 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-09 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-09 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2004-07-09 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-07 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-05-07 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2004-05-10 00:00:00 | TO SFD RACK/E | | 2004-05-07 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-27 |
Time |
06:46 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-01-27 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2005-01-27 00:00:00 | DENIED: | | | 1.ONLY ONE SET OF PLANS SUBMITTED FOR | | | APPROVAL.TWO SETS REQUIRED PER 2001 | | | FBC 104.2.1.PLEASE PROVIDE ADDITIONAL | | | SET. | | | | | | 2.PLEASE CLARIFY RETURN AIR FROM THE | | | LAUNDRY AREA.THIS IS NOT A HABITABLE | | | ROOM AND DOES NOT REQUIRE A RETURN. | | | | | | CALLED CONTRACTOR 1-27-05 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-02 |
Time |
14:05 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-02 |
Time |
13:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
19:32 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-14 |
Time |
09:59 |
Sent To |
P |
|
| Notes |
| 2004-05-14 00:00:00 | DENIED: | | | 1. RETURN AIR REQUIRED FROM THE MASTER | | | BEDROOM AREA. | | | | | | 2.RETURN AIR REQURIED FROM THE STUDY | | | AREA. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
19:31 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-07-27 |
Time |
19:31 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
18:56 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-19 |
Time |
17:53 |
Sent To |
B |
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT M-2 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) WASH MACHINE REQUIRES A STANDPIPE & | | | A CLEANOUT. CLEANOUT SHALL BE INSTALLED | | | 4' ABOVE THE FLOOR FOR ACCESS. SECTIONS | | | 1002.1 & 708.10 | | | B) THE SIZE OF THE DRAINAGE PIPING | | | SHALL NOT BE REDUCED IN SIZE IN THE DIR- | | | ECTION OF FLOW. WASH MACHINE SHOWS 4" | | | PIPE THEN REDUCING TO 2" PIPE. SECTION | | | 704.2. | | | C) TUB AND SHOWER SHALL BE CONNECTED TO | | | SANITARY BLDG DRAIN UNDERGROUND NOT UP | | | ON THE STACK. SEE RED LINE CORRECTION. | | | SECTION 102.4 | | | 2) THE PERSONAL SIGNATURE OF THE ARCHIT- | | | ECT SHALL APPEAR ON ALL ARCHITECTURAL | | | DOCUMENTS TO BE FILED FOR PUBLIC RECORD. | | | INITIALS ARE NOT ACCEPTABLE PER DPBR. | | | FAC 61G1-16;003 & FS 481.2055 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-03 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-04 |
Time |
15:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-07 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-07 |
Time |
11:57 |
Sent To |
I |
|
| Notes |
|
|