Plan Review Details - Permit 04050145
Plan Review Stops For Permit 04050145
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-08-17 Cont ID  
Sent By alange Date 2004-08-17 Time 10:48 Rev Time 1.00
Received By alange Date 2004-08-17 Time 10:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-26 Cont ID  
Sent By pkrauss Date 2004-08-17 Time 10:21 Rev Time 1.50
Received By alange Date 2004-05-26 Time 15:25 Sent To  
Notes
2004-05-26 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.ENERGY CALS NOT SIGNED BY OWNER -
 AGENT.SIGN BOTH COPIES.
  
 4. CONSTRUCTION GLASS INDUSTRIES
 PRODUCTS NOT LISTED ON DCA PRODUCT
 APPROVAL SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5. ROOF PRODUCT APPROVALS NOT SUBMITTED.
  
 6.PLANS SPEC PGT WINDOWS.PRODUCT
 APPROVALS DON'T MATCH SPECS ON PLANS.
 SUBMIT 2 COPIES OF ALL PRODUCT APPROVALS
  
 7.IMPACT PROTECTION REQUIRED.
  
 8.INSULATION "R" VALUE ON PLANS DON'T
 MATCH ENERGY CALCS.
  
 9. SHOW WINDOW AND DOOR BUCK DETAILS
 HAVING THEM COMPLY WITH FBC 1707.4.4.2
  
 10.BASSED ON SBCCI BUILDING VALUATION
 DATA, THE VALUE HAS BEEN REVISED TO
 $47,330. ADDITION PERMIT FEES ARE DUE.
 ANY QUESTIONS CALL ME
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-06 Cont ID  
Sent By btrobaug Date 2004-08-06 Time 13:23 Rev Time 0.50
Received By btrobaug Date 2004-08-06 Time 12:56 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:39 Rev Time 0.75
Received By btrobaug Date 2004-05-10 Time 12:03 Sent To P
Notes
2004-05-10 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE A RISER DIAGRAM AND LOAD
 CALCULATIONS PER 215.5.
  
 2} PROVIDE AIC RATINGS PER 110.9 & 10.
  
 3} PROVIDE A PANEL SCHEDULE TO SHOW
 COMPLIANCE WITH THE FOLLOWING ARTICLES:
 A) 210.12.ARC FAULT.
 B) 210.11(C)(3).BATH RECEPTACLES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:39 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:39 Sent To E
Notes
2004-07-30 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-05-10 Time 07:37 Rev Time 0.00
Received By csiegber Date 2004-05-10 Time 07:37 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-06 Cont ID  
Sent By mmclean Date 2004-05-07 Time 08:21 Rev Time 0.00
Received By csiegber Date 2004-05-06 Time 14:51 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-08-17 Cont ID  
Sent By pkrauss Date 2004-08-17 Time 10:20 Rev Time 0.30
Received By pkrauss Date 2004-08-17 Time 10:11 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-24 Cont ID  
Sent By kstevens Date 2004-08-14 Time 13:14 Rev Time 0.50
Received By hmoser Date 2004-05-24 Time 14:01 Sent To B
Notes
2004-05-24 00:00:00PLAN DENIED
 PLEASE PROVIED MANUAL (J) WITH PLANS.
 PLAN IS REQUIRED TO HAVE A SIGNATURE AND
 SEAL.PLAN IS ON ARCHITECT OR INGINEER
 PAPER
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-08-14 Cont ID  
Sent By kstevens Date 2004-08-14 Time 13:14 Rev Time 0.25
Received By kstevens Date 2004-08-14 Time 13:14 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-24 Cont ID  
Sent By btrobaug Date 2004-08-06 Time 13:24 Rev Time 0.50
Received By kstevens Date 2004-05-24 Time 12:43 Sent To M
Notes
2004-05-24 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) PLANS HAVE BEEN STAMPED APPROVED, BUT
 WILL NOT BE PASSED ON THE COMPUTER AS
 THE PLANS, (EACH SHEET), IS REQUIRED TO
 HAVE THE PRINTED NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN
 ON THE PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-05-07 Cont ID  
Sent By csiegber Date 2004-05-06 Time 14:51 Rev Time 0.00
Received By mmclean Date 2004-05-07 Time 08:21 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved