| Plan Review Stops For Permit 04050078 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-16 |
Time |
16:46 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-06-16 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-14 |
Time |
13:14 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-05-19 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | 1. NOT SUFFICENT INFORMATION SUBMITTED | | | FOR A BUILDING REVIEW. | | | WEST PALM BEACH AMMENDMENT TO THE FBC | | | SEC'S 104.2, 104.2.1, 104.2.1.2 AND | | | 104.2.4 | | | SUBMIT 2 COPIES OF CLEAR DRAWINGS | | | SHOWING NEW AND EXISTING WORK. | | | SITE DRAWINGS, SURVEY, ELEVATION | | | DRAWINGS FOR EACH SIDE. PRODUCT | | | APPROVALS FOR EXTERIOR WINDOWS DOORS AND | | | ROOFING.FRAMING DETAILS, WALL | | | SECTIONS. TOO MANY ITEMS TO LIST. | | | | | | PLEASE CALL ME IF YOU HAVE QUESTIONS. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-11 |
Time |
10:05 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-11 |
Time |
10:05 |
Sent To |
M |
|
| Notes |
| 2004-06-11 00:00:00 | ** REDLINED ** | | | ONE SD TO BE ADDED TO PLAYROOM. CONNECT | | | TO EXISTING SD'S WIRED INLINE. | | | PER NFPA-72 8-1.4.1.6.2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:42 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
07:55 |
Sent To |
Z |
|
| Notes |
| 2004-05-08 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT PLANS/ DRAWINGS | | | FOR SCOPE OF WORK BEINGDONE. | | | COPIES SEEM TO SHOW SOME EXISTING AND | | | NEW ?? | | | PERMIT APPLICATION MENTIONS TO EXTEND | | | 2ND FLR, HOWEVER THERE IS NOT ENOUGH | | | INFORMATION FOR THIS FOR REVIEW. | | | SQ FT? CIRCUITING? PANEL SCHEDULE? | | | USEAGE? ETC. | | | PLEASE ALSO SEE FBC 104.2.1 FOR PLANS. | | | PLANS MUST ALSO CONTAIN PRINTED NAME | | | AND SIGNATURE FOR PERSON RESPONSIBLE FOR | | | PLANS. | | | | | | PLANS BEING SENT TO ZONING FOR REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-08 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2004-06-08 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
10:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-11 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-11 |
Time |
13:05 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-10 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
13:19 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-14 |
Time |
13:14 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-14 |
Time |
12:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-11 |
Time |
10:05 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-05-17 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | PLAN DENIED | | | 1) COULD NOT UNDERSTAND THE A/C PLAN | | | 2) NEED MORE INFORMATION | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-11 |
Time |
13:05 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
M |
|
| Notes |
| 2004-05-17 00:00:00 | PROVISO: | | | ALL WORK SUBJECT TO FIELD INSPECTOR | | | APPROVAL.` | | | ` | | | ` |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-08 |
Time |
10:29 |
Sent To |
I |
|
| Notes |
| 2004-06-08 00:00:00 | ALL WORK INTERIOR, SETBACKS DOES NOT | | | CHANGE MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-10 |
Time |
13:22 |
Sent To |
I |
|
| Notes |
| 2004-05-10 00:00:00 | DENIED, NEED TO PROVIDE 2 COPY OF SURVEY | | | SHOWING THE ADDITION.CALLED OWNER MM |
|
|