| Plan Review Stops For Permit 04050072 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-19 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-19 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2005-08-19 00:00:00 | REVISED ENERGY CALCS. FOR R-VALUE OF | | | INSULATION AT EXTERIOR MASONRY WALLS | | | FROM R-5.0 TO R-4.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-10 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-10 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2005-02-10 00:00:00 | REVISION TO CHANGE WOOD HEADERS AT | | | PORCHES TO POURED LINTELS IS DENIED. | | | REVISIONS TO MASTERED PLANS ARE NOT | | | ALLOWED AFTER SOME MODELS ARE BUILT TO | | | ORIGINAL MASTER PLAN. WHICH IS THE CASE | | | PER TELEPHONE CONVERSATION WITH THE | | | CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-02 |
Time |
15:59 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-11-02 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-13 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2004-10-13 00:00:00 | DENIED | | | | | | 1) THE TRUSS LAYOUT AND DRAWINGS ARE | | | REQUIRED TO BE REVIEWED BY THE ARCHITECT | | | THEY ARE TO BE STAMPED AND SIGNED BY HIM | | | AS BEING REVIEWED AND ACCEPTED. | | | | | | 2) SHEET A2.01 IS MISSING FROM ONE OF | | | THE SETS OF PLANS. | | | | | | 3) THE ROOF FRAMING PLAN ON SHEET S2.03 | | | DOES NOT SPECIFY THE CONNECTORS FOR THE | | | FOUR BEARING POINT FOR TRUSSES A3 AND | | | A4. SEE TRUSS DRAWINGS AND LAYOUT. | | | PLEASE CORRECT. | | | | | | 4) THE STORM PANEL KEY AND INSTALLATION | | | PLAN SPECIFIES PANELS FOR THE EXTERIOR | | | DOOR AT THE KITCHEN. THE PLANS SPECIFY | | | A METAL DOOR WITHOUT GLAZING AT THIS | | | LOCATION. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:42 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-10-07 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2004-10-07 00:00:00 | DENIED | | | | | | 1) THE VALUES LISTED IN THE TABLE IN | | | DETAIL 5 ON SHEET S2.03 FOR THE USP | | | THD28-2 CONNECTOR ARE INCORRECT. SEE | | | 2004 USP CATALOG. | | | | | | 2) THE STORM PANEL SCHEDULE INDICATES | | | STORM PANELS FOR THE FRONT DOOR. THIS | | | CONFLICTS WITH THE PLANS AND THE PRODUCT | | | APPROVAL WHICH SPECIFY AN IMPACT RATED | | | DOOR. PLEASE CLARIFY. | | | | | | 3) THE TRUSS LAYOUT AND DRAWINGS HAVE | | | NOT BEEN REVIEWED AND APPROVED BY THE | | | ARCHITECT. THEY ARE TO BE STAMPED AND | | | SIGNED BY HIM AS BEING REVIEWED AND | | | ACCEPTED. | | | | | | 4) THE ROOF FRAMING PLAN ON S2.03 IS NOT | | | CLEAR ON THE LOCATION AND UPLIFTS FOR | | | THE A3,A4 AND A5 TRUSSES WHICH HAVE | | | FOUR BEARING POINTS. PLEASE CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:44 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-08-16 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2004-08-16 00:00:00 | DENIED | | | | | | 1) THE ENERGY CALCULATIONS ARE REQUIRED | | | TO BE WORST CASE FOR MASTERED MODELS. | | | THE A/C AREA ON THE PLANS AND ON THE | | | ENERGY CALC. FORMS DO NOT MATCH. | | | | | | 2) DETAIL #5 ON S2.03 IS INCORRECTLY | | | NUMBERED AS 201. THE THD28-2 DID NOT GET | | | CHANGED TO THE THDH28-2, WHICH HAS THE | | | UPLIFT OF 3185# THAT IS SPECIFIED. | | | | | | 3) SPECIFY ON SHEET S2.01 THAT THE | | | FINISH FLOOR OF THE MONOLITHIC SLAB IS | | | REQUIRED TO BE A MINIMUM OF 4" ABOVE | | | FINAL GRADE AT HABITABLE AREAS. SEE CITY | | | OF WPB AMENDMENTS TO FBC 1804.1.7. | | | | | | 4) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE INSTALLATION TYPE AND FASTENERS THAT | | | WILL BE USED BY CIRCLING OR HIGHLIGHTING | | | THE ITEMS ON THE INSTALLATION DRAWINGS. | | | | | | 5) THE PRODUCT APPROVAL FOR THE PGT SH | | | 4000 WINDOWS DOES NOT MATCH THE NOA | | | NUMBERS ON THE MIAMI-DADE NOA THAT WAS | | | SUBMITTED. SUBMIT THE CORRECT NOA. ONLY | | | ONE COPY WAS SUBMITTED. TWO COPIES ARE | | | REQUIRED. | | | | | | 6) THE PRODUCT APPROVAL FOR THE PGT | | | FRENCH DOOR DOES NOT MATCH THE NOA | | | NUMBERS ON THE MIAMI-DADE NOA THAT WAS | | | SUBMITTED. SUBMIT THE CORRECT NOA. | | | | | | 7) THE TRUSS LAYOUT IS TO BE REVIEWED BY | | | THE ARCHITECT OF RECORD AND STAMPED AS | | | APPROVED BY HIM. | | | | | | 8) THE TRUSS LAYOUT AND TRUSS DRAWINGS | | | ARE REQUIRED TO HAVE THE ORIGINAL WET | | | SIGNATURE OF THE TRUSS ENGINEER. SEE | | | FAC 61G15-23.002. | | | | | | 9) TRUSSES A3, A4, AND A5 HAVE FOUR | | | BEARING POINTS INDICATED ON THE TRUSS | | | DRAWINGS. THE ROOF FRAMING PLANS ONLY | | | SPECIFY CONNECTORS FOR THREE BEARING | | | POINTS. PLEASE CORRECT. | | | | | | 10) THE TRUSS LAYOUT NOTES THAT THE | | | BEAMS AT THE FRONT AND REAR PORCHES ARE | | | BY BUILDER. SHEET S2.03 OF THE PLANS | | | SPECIFY WOOD GIRDER TRUSSES. PLEASE | | | CORRECT. IF BEAMS ARE BY BUILDER PROVIDE | | | DETAILS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-19 |
Time |
15:41 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-06-02 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | DENIED | | | | | | 1) SUBMIT TRUSS DRAWINGS AND LAYOUT THAT | | | HAVE BEEN REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD. | | | | | | 2) THE ENERGY CALCULATIONS ARE REQUIRED | | | TO BE WORST CASE FOR MODELS. THE FORM IS | | | REQUIRED TO BE SIGNED AND DATED BY THE | | | OWNER/AGENT. THE CONDITIONED FLOOR AREA | | | ON THE FORM AND THE PLANS SHOULD BE THE | | | SAME. | | | | | | 3) SPECIFY THE BOTTOM CORD LIVE LOAD ON | | | THE PLANS. SEE 2001 FBC TABLE 1604.1. | | | | | | 4) THE MONOLITHIC FOOTING IN THE WALL | | | SECTION ON S 2.01 DOES NOT CORRESPOND | | | WITH THE F1 FOOTING IN THE SCHEDULE. | | | PLEASE CORRECT. | | | | | | 5) THE ISOLATED PAD DETAIL ON S 2.01 IS | | | INCORRECTLY LABELED AS 7. IT SHOULD BE | | | LABELED 4. | | | | | | 6) SPECIFY THE MATERIAL USED FOR THE | | | CEILINGS (DIAPHRAGM) OF THE COVERED | | | PORCHES. | | | | | | 7) SUBMIT STATE PRODUCT APPROVALS FOR | | | THE USP CONNECTORS.(HLPTA75, TA16, RT16F | | | RT22T, THD28-2) | | | | | | 8) THE USP THD28-2 HAS A MAXIMUM UPLIFT | | | OF 2390# AT 133% PER 2004 USP CATALOG. | | | PLEASE REVISE DETAIL 5 ON S 2.03. | | | (THE THDH28-2 HAS AN UPLIFT OF 3185#.) | | | | | | 9) THE EXTERIOR WALLS AT THE REAR PORCH | | | ARE NOT SHOWN ON THE ROOF FRAMING PLAN | | | ON S2.03. | | | | | | 10) ON S3.01 THE WALL SHEATHING IS | | | SPECIFIED AS 15/32" IN ONE PLACE AND | | | 5/8" IN ANOTHER. PLEASE CORRECT. | | | | | | 11) THE ROOF SHEATHING IS INCORRECTLY | | | SPECIFIED AS 15/32" ON SHEET S3.01. CITY | | | OF WPB AMENDMENTS TO FBC TABLE 2309.3A | | | REQUIRES MINIMUM 19/32" SHEATHING. | | | | | | 12) CITY AMENDMENTS TO FBC TABLE 2306.1 | | | REQUIRES ROOF SHEATHING TO BE NAILED AT | | | 4"OC ON THE EDGES AND 6"OC INTERMEDIATE | | | IN ZONE 3 WHICH INCLUDE THE CORNERS OF | | | HIP ROOFS. PLEASE REVISE NOTES ON S3.01. | | | | | | 13) PLEASE UPDATE THE ACI EDITIONS THAT | | | ARE SPECIFIED ON S3.01 TO 2002 EDITIONS | | | PER FBC CHAPTER 35. SEE NOTES ON THE | | | PLAN. | | | | | | 14) PROVIDE A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE INSTALLATION TYPE AND FASTENERS THAT | | | WILL BE USED BY CIRCLING OR HIGHLIGHTING | | | APPROPRIATE ITEMS ON THE INSTALLATION | | | DRAWINGS. | | | | | | 15) SUBMIT STATE PRODUCT APPROVALS FOR | | | THE FOLLOWING ITEMS: | | | - SINGLE OUTSWING DOOR AT THE KITCHEN | | | - DOUBLE OUTSWING DOORS AT STORAGE | | | - ALUMINUM SOFFIT | | | - TRUSS CONNECTORS | | | | | | 16) ONE OF THE PRODUCT APPROVALS FOR THE | | | STORM PANELS IS MISSING THE INSTALLATION | | | DRAWINGS. | | | | | | THE FOLLOWING ITEMS WILL BE REQUIRED TO | | | BE SUBMITTED FOR EACH PERMIT APPLICATION | | | UNDER THE MASTER. | | | - NOTICE OF COMMENCEMENT | | | - PAID RECEIPT FOR COUNTY IMPACT FEES. | | | (PLANS MUST BE STAMPED BY COUNTY) | | | - A SURVEY | | | - A SUBSURFACE SOIL REPORT(FBC 1804.2.2) | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:44 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
06:44 |
Sent To |
B |
|
| Notes |
| 2004-10-05 00:00:00 | MASTER MODEL "A" |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:22 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-10 |
Time |
15:37 |
Sent To |
P |
|
| Notes |
| 2004-08-10 00:00:00 | ***UNSAT *** | | | | | | 1)NOTE: PLEASE SEE LOAD SHOWN FOR COND | | | UNIT AS 10KW, IF COOLING LOAD IS LARGER | | | THAN HEAT, THEN COOLING LAOD IS FIGURED | | | IN LAOD CALCS. PLEASE VERIFY, APPEARS | | | TO BE A MISPRINT FOR A 2.5 TON UNIT. | | | | | | 2) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | SEE NEW RECEPT ADDED FOR PREVIOUS NOTES. | | | | | | 3)NOTE: PLEASE SEE 210.52C3 AND C5 FOR | | | PENINSULAR/WALL RECEPT SPACING. PLEASE | | | VERIFY IF RECEPT SHOWN IS FOR PENINSULAR | | | OR WALL. ? | | | PLEASE ALSO SEE 210.52 FOR 6' REQ'MENT. | | | | | | 4)NOTE: PLEASE SEE GEN NOTES#3 LAST | | | LINE MENTIONS RECEPTS TO BE ARC-FAULT | | | PROTECTED. | | | PLEASE SEE NEW NOTE ADDED. | | | | | | PLEASE SEE PLANS ARE ONLY IN FOR PLAN | | | REVIEW. THEY ARE ALSO FOR MASTERS WHICH | | | REQUIRES ALL TO BE 100% AND NO REDLINES | | | CAN BE DONE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
14:02 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-10 |
Time |
07:54 |
Sent To |
M |
|
| Notes |
| 2004-05-10 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE PANEL SCHEDULE SHOWS | | | PANEL AS MCB AND YET PLANS/RISER SHOWS | | | A MAIN DISCONNECT? | | | A MCB IS PERMITTED BUT NOT REQ'D. IF | | | SHOWN ON PLANS THEN IT MUST BE INSTALLED | | | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM MAIN TO PANEL. | | | 250.110, SIZE PER 250.122. | | | | | | 3)NOTE: PLEASE SEE 210.52 FOR RECEPT | | | SPACING. 2', 6',12' | | | | | | 4)NOTE: PLEASE SEE OCP/AWG SHOWN FOR | | | 2.5TON A/C COND UNIT. THIS SEEMS TO BE | | | TOO HIGH FOR OCP. | | | | | | 5)NOTE: PLEASE SHOW MAIN DISC NEXT TO | | | METER ON PLANS. | | | | | | 6)NOTE: DISC FOR A/CTO MEET 110.26, | | | SHOWN BEHIND UNIT. | | | | | | 7)NOTE: PLEASE IDENTIFY ARC FAULT PER | | | 2002 NEC. 210.12B WHICH REQ'S ALL OUTLET | | | S. SD'S, RECEPTS, LTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
17:27 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
15:41 |
Sent To |
P |
|
| Notes |
| 2005-01-14 00:00:00 | TO "P" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:53 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | TO RM DESK/ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-12 |
Time |
16:42 |
Sent To |
B |
|
| Notes |
| 2004-10-12 00:00:00 | TO RM DESK/JOURNAL ENTRY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-24 |
Time |
09:22 |
Sent To |
E |
|
| Notes |
| 2004-09-24 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
14:02 |
Sent To |
E |
|
| Notes |
| 2004-08-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
14:20 |
Sent To |
E |
|
| Notes |
| 2004-05-04 00:00:00 | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-10-13 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-13 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2004-10-13 00:00:00 | OK PER P.KRAUSS ON 8/12/04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-12 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-10 |
Time |
07:14 |
Sent To |
P |
|
| Notes |
| 2004-05-14 00:00:00 | DENIED: | | | 1.RETURN AIR TO THE MASTER BEDROOM IS | | | NOT SIZED PROPERLY.ALL SUPPLY AIR TO | | | THE MASTER SUITE IS TO BE INCLUDED FOR | | | THE "TOTAL" OF SUPPLY AIR.SUPPLY AIR | | | 7" TO THE BEDROOM 6" TO THE BEDROOM FOR | | | A TOTAL OF 66 SQ INCHES MULTIPY BY 1.5 | | | EQUALS A TOTAL OF 99 SQ INCHES THEREFOR | | | RETURN AIR SHOULD BE A MINIMUM OF 12". | | | | | | 2.SUPPLY AIR DUCT TO BEDROOM #2 IS | | | NOT SIZED. | | | | | | 3.PROVIDE OUTSIDE AIR CALCULATIONS PER | | | 402.2 OR 403.3 OF THE 2001 FBC(M). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-02-05 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-02-05 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2005-02-05 00:00:00 | WATER HEATER LOCATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-12 |
Time |
10:49 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-08-12 |
Time |
10:49 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-10 |
Time |
15:37 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-19 |
Time |
15:40 |
Sent To |
B |
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT 2.01 SANITARY RISER DIAGRAM. THE | | | TRAPS FOR THE TUB ARE "S" TRAPS AS SHOWN | | | AND ARE NOT ALLOWED PER SECTION 1002.3 | | | - ANY PORTION OF THE DRAINAGE SYSTEM IN- | | | STALLED UNDERGROUND SHALL NOT BE LESS | | | THAN 2". SECTION 710.3 - WASH MACHINE | | | DRAIN REQUIRES A TRAP, A STANDPIPE, AND | | | A CLEANOUT. THE CLEANOUT SHALL BE MIN. | | | 4' ABOVE THE FLOOR FOR ACCESS. SEE SECT- | | | IONS 1002.1, 802.4, & 708.10. | | | 2) 2" SHOWN TO WATER CLOSETS. SUBMIT | | | MANUF. SPECIFICATION SHEETS INDICATING | | | FIXTURE OUTLET SIZE. SEE FOOTNOTE D FOR | | | TABLE 709.1 | | | 3) SEE RED LINE CORRECTIONS ON SHEET | | | P2.01. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|