Plan Review Details - Permit 04050070
Plan Review Stops For Permit 04050070
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status N Date 2005-08-23 Cont ID  
Sent By rmcdouga Date 2005-08-23 Time 17:20 Rev Time 0.00
Received By rmcdouga Date 2005-08-23 Time 17:20 Sent To  
Notes
2005-08-23 00:00:00SUBMITTED REVISED ENERGY CALCULATIONS.
 CHANGED EXTERIOR FOIL FROM R-5 TO R-4.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status N Date 2005-02-10 Cont ID  
Sent By rmcdouga Date 2005-02-10 Time 07:27 Rev Time 0.00
Received By rmcdouga Date 2005-02-10 Time 07:27 Sent To  
Notes
2005-02-10 00:00:00REVISION TO CHANGE WOOD HEADERS AT
 PORCHES TO POURED LINTELS IS DENIED.
 REVISIONS TO MASTERED PLANS ARE NOT
 ALLOWED AFTER MODELS ARE BUILT TO MATCH
 THE ORIGINAL MASTERED PLAN. THIS IS THE
 CASE PER CONVERSATION WITH THE
 CONTRACTOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-11-02 Cont ID  
Sent By rmcdouga Date 2004-11-02 Time 15:41 Rev Time 2.00
Received By rmcdouga Date 2004-11-02 Time 15:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-10-13 Cont ID  
Sent By csiegber Date 2004-10-20 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2004-10-13 Time 13:16 Sent To  
Notes
2004-10-13 00:00:00DENIED
  
 1) THE TRUSS LAYOUT AND DRAWINGS ARE
 REQUIRED TO BE REVIEWED AND APPROVED BY
 THE ARCHITECT. THEY ARE TO BE STAMPED
 AND SIGNED BY HIM AS BEING REVIEWED AND
 ACCEPTED.
  
 2) SHEET A2.01 IS MISSING FROM ONE OF
 THE PLAN SETS.
  
 3) THE STORM PANEL KEY PLAN AND SCHEDULE
 INDICATE THAT THE EXTERIOR DOOR AT THE
 KITCHEN IS TO BE SHUTTERED. THE PLANS
 SHOW A METAL DOOR WITH NO GLAZING.
 PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-10-08 Cont ID  
Sent By csiegber Date 2004-10-12 Time 16:43 Rev Time 2.00
Received By rmcdouga Date 2004-10-08 Time 08:59 Sent To  
Notes
2004-10-08 00:00:00DENIED
  
 1) THE VALUES LISTED IN THE TABLE FOR
 THE USP THD28-2 CONNECTOR IN DETAIL 5 ON
 S2.03 ARE INCORRECT.
  
 2) THE STORM PANEL KEY/INSTALLATION
 SCHEDULE INDICATES STORM PANELS ON THE
 FRONT DOOR. THIS CONFLICTS WITH THE PLAN
 AND PRODUCT APPROVAL WHICH SPECIFY AN
 IMPACT RESISTANT GLAZED DOOR. PLEASE
 CORRECT.
  
 3) THE TRUSS LAYOUT AND DRAWINGS ARE
 REQUIRED TO BE REVIEWED AND APPROVED BY
 THE ARCHITECT. THEY ARE TO BE STAMPED
 AND SIGNED BY HIM AS BEING REVIEWED AND
 ACCEPTED.
  
 4) THE ROOF FRAMING PLAN ON S2.03 DOES
 NOT CLEARLY INDICATE THE UPLIFT AND
 CONNECTORS FOR THE ALL FOUR BEARING
 POINTS FOR TRUSSES A3, A4 AND A5. PLEASE
 CORRECT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-08-17 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 06:44 Rev Time 0.00
Received By rmcdouga Date 2004-08-17 Time 09:00 Sent To  
Notes
2004-08-17 00:00:00DENIED
  
 1) THE ENERGY CALCULATIONS ARE REQUIRED
 TO BE WORST CASE FOR MASTERED MODELS.
 THE FORM IS REQUIRED TO BE SIGNED AND
 DATED BY THE OWNER/AGENT. THE A/C AREA
 ON THE PLANS AND ON THE ENERGY CALC.
 FORMS DO NOT MATCH.
  
 2) DETAIL #5 ON S2.03 IS INCORRECTLY
 NUMBERED AS 201. THE THD28-2 DID NOT
 GET CHANGED TO THE THDH28-2, WHICH HAS
 THE UPLIFT OF 3185# THAT IS SPECIFIED.
  
 3) SPECIFY ON SHEET S2.01 THAT THE
 FINISH FLOOR OF THE MONOLITHIC SLAB IS
 REQUIRED TO BE A MINIMUM OF 4" ABOVE
 FINAL GRADE AT HABITABLE AREAS. SEE
 CITY OF WPB AMENDMENTS TO FBC 1804.1.7.
  
 4) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY
 THE INSTALLATION TYPE AND FASTENERS THAT
 THE INSTALLATION TYPE AND FASTENERS THAT
 WILL BE USED BY CIRCLING OR HIGHLIGHTING
 THE ITEMS ON THE INSTALLATION DRAWINGS.
  
 5) THE PRODUCT APPROVAL FOR THE PGT SH
 4000 WINDOWS DOES NOT MATCH THE NOA
 NUMBERS ON THE MIAMI-DADE NOA THAT WAS
 SUBMITTED. SUBMIT THE CORRECT NOA.
  
 6) THE PRODUCT APPROVAL FOR THE PGT
 FRENCH DOOR DOES NOT MATCH THE NOA
 NUMBERS ON THE MIAMI-DADE NOA THAT WAS
 SUBMITTED. SUBMIT THE CORRECT NOA.
  
 7) THE TRUSS LAYOUT IS TO BE REVIEWED BY
 THE ARCHITECT OF RECORD AND STAMPED AS
 APPROVED BY HIM.
  
 8) THE TRUSS LAYOUT AND TRUSS DRAWINGS
 ARE REQUIRED TO HAVE THE ORIGIONAL WET
 SIGNATURE OF THE TRUSS ENGINEER. SEE
 FAC 61G15-23.002.
  
 9) TRUSSES A3, A4, AND A5 HAVE FOUR
 BEARING POINTS INDICATED ON THE TRUSS
 DRAWINGS. THE ROOF FRAMING PLANS ONLY
 SPECIFY CONNECTORS FOR THREE BEARING
 POINTS. PLEASE CORRECT.
  
 10) THE TRUSS LAYOUT NOTES THAT THE
 BEAMS AT THE FRONT AND REAR PORCHES ARE
 BY BUILDER. SHEET S2.03 OF THE PLANS
 SPECIFY WOOD GIRDER TRUSSES. PLEASE
 CORRECT. IF BEAMS ARE BY BUILDER PROVIDE
 DETAILS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-03 Cont ID  
Sent By pkrauss Date 2004-08-12 Time 11:36 Rev Time 3.00
Received By rmcdouga Date 2004-06-03 Time 09:46 Sent To  
Notes
2004-06-03 00:00:00DENIED
  
 1) SUBMIT TRUSS DRAWINGS AND LAYOUT THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD.
  
 2) THE ENERGY CALCS ARE REQUIRED TO BE
 WORST CASE FOR THE MODEL. THE FORM IS
 REQUIRED TO BE SIGNED AND DATED BY THE
 OWNER AGENT. THE CONDITIONED FLOOR AREA
 ON THE FORM AND THE PLANS SHOULD BE THE
 SAME.
  
 3) SPECIFY THE BOTTOM CORD LIVE LOAD ON
 THE PLANS. SEE 2001 FBC TABLE 1604.1.
  
 4) THE FLOOR PLAN ON A2.01 DOES NOT
 CORRESPOND WITH THE REST OF THE PLANS.
 SEE SOUTH ELEVATION AT BEDROOM 3.
  
 5) THE FOOTING SHOWN IN THE WALL SECTION
 ON S2.01 DOES NOT CORRESPOND WITH THE
 FOOTING SCHEDULE. PLEASE CORRECT.
  
 6) THE ISOLATED PAD DETAIL ON S2.01 IS
 INCORRECTLY LABELED AS 7. IT SHOULD BE
 4.
  
 7) THE TRUSS CONNECTOR IN THE WALL
 SECTION ON S2.01 SHOULD BE USP.
  
 8) SPECIFY THE MATERIAL USED FOR THE
 CEILINGS (DIAPHRAGM) OF THE COVERED
 PORCHES.
  
 9) SUBMIT STATE PRODUCT APPROVALS FOR
 THE USP CONNECTORS.
  
 10) THE USP THD28-2 HAS A MAXIMUM UPLIFT
 OF 2390# AT 133% PER 2004 USP CATALOG.
 PLEASE REVISE DETAIL 5 ON S2.03.
  
 11)THE UPLIFT FOR THE ROOF TRUSS GIRDERS
 AT THE LEFT SIDE ARE NOT SPECIFIED OR
 ARE INCORRECT. SEE NOTES ON PLAN.
  
 12) THE EXTERIOR WALLS AT THE REAR PORCH
 ARE NOT SHOWN ON THE ROOF FRAMING PLAN
 ON S2.03.
  
 13) ON S3.01 THE WALL SHEATHING IS
 SPECIFIED AS 15/32" IN ONE PLACE AND
 5/8" IN ANOTHER. PLEASE CLARIFY.
  
 14) THE ROOF SHEATHING IS INCORRECTLY
 SPECIFIED AS 15/32" ON SHEET S3.01. CITY
 OF WPB AMENDMENTS TO FBC TABLE 2309.3A
 REQUIRES SHEATHING TO BE A MINIMUM OF
 19/32".
  
 15) CITY AMENDMENTS TO FBC TABLE 2306.1
 REQUIRES ROOF SHEATHING TO BE NAILED AT
 4"OC ON THE EDGES AND 6"OC INTERMEDIATE
 IN ZONE 3, WHICH INCLUDES THE COORNERS
 OF HIP ROOFS. PLEASE REVISE NOTES ON
 S3.01.
  
 16) PLEASE UPDATE THE ACI EDITIONS THAT
 ARE SPECIFIED ON S3.01 TO 2002 EDITIONS
 AS REFERENCED BY THE 2001 FBC CHAPTER 35
 SEE NOTES ON THE PLANS.
  
 17) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY
 THE INSTALLATION TYPE AND FASTENERS THAT
 WILL BE USED BY CIRCLING OR HIGHLIGHTING
 APPROPRIATE ITEMS ON THE INSTALLATION
 DRAWINGS.
  
 18) SUBMIT STATE PRODUCT APPROVALS FOR
 THE FOLLOWING ITEMS:
 - SINGLE OUTSWING DOOR AT KITCHEN
 - DOUBLE OUTSWING DOOR AT STORAGE
 - ALUMINUM SOFFIT
 - TRUSS CONNECTORS
  
 19) ONE OF THE PRODUCT APPROVALS FOR THE
 STORM PANELS IS MISSING THE INSTALLATION
 DRAWINGS.
  
 THE FOLLOWING ITEMS WILL BE REQUIRED TO
 BE SUBMITTED FOR EACH PERMIT APPLICATION
 UNDER THE MASTER.
 - NOTICE OF COMMENCEMENT
 - PAID RECEIPT FOR COUNTY IMPACT FEES
 AND PLANS STAMPED BY THE COUNTY
 - TWO COPIES OF SURVEY
 - TWO COPIES OF SUBSURFACE SOIL REPORT
 PER FBC 1804.2.2
  
 IF YOU HAVE QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-10-05 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 06:34 Rev Time 0.25
Received By dpalmer Date 2004-10-05 Time 06:24 Sent To B
Notes
2004-10-05 00:00:00MASTER MODEL "B"

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-09-24 Time 09:23 Rev Time 0.33
Received By dpalmer Date 2004-08-10 Time 15:11 Sent To P
Notes
2004-08-10 00:00:00*** UNSAT ***
  
 1)NOTE: PLEASE SEE OUTLETS FOR KITCHEN
 PENINSULAR/WALL AREA IS NOT CLEAR.
 PENINSULAR IS REQ'D TO GFI RECEPT PER
 210.52C3, PLEASE ALSO SEE (C5)
  
 2)NOTE: PLEASE SEE ADDED RECEPT FOR
 COND UNIT TO BE INDICATED AS WP/GFI.
 210.8 AS ON SYMBOL SCHEDULE.
  
 3)NOTE: PLEASE ALSO SEE RECEPT ADDED TO
 KITCHEN COUNTER, TO BE SHOWN AS GFI/
 GFI PROTECTED PER 210.8A6
  
 4)NOTE: PLEASE SEE OCP WAS CORRECTED FOR
 COND UNIT, HOWEVER LOAD IS SHOWN AT 10KW
 , PLEASE SEE IF LOAD OFR COND UNIT IS
 HIGHER THAN HEATING LOAD, THEN COND UNIT
 LOAD IS FIGNURED IN LOAD CALCS. THIS
 SEEMS TO BE A MISPRINT.
 2.5 TON CU LOAD IS MOST LIKELY NOT MORE
 THAN HEAT LOAD. PLEASE VERIFY.
  
 5)NOTE: PLEASE SEE GENERAL NOTES, NOTE
 #3 LAST LINE STILL MENTIONS ARC-FAULT
 FOR RECEPTS. PLEASE REMOVE DUE TO NEW
 NOTE BEING ADDED BELOW THIS.
  
 PLEASE NOTE: THESE PLANS ARE ONLY IN FOR
 "PLAN REVIEW" FOR A MASTER. THIS REQUIRE
 'S EVERY ITEM TO BE 100% CORRECT AND
 NO REDLINES CAN BE DONE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-08-03 Time 14:19 Rev Time 0.50
Received By dpalmer Date 2004-05-10 Time 06:55 Sent To M
Notes
2004-05-10 00:00:00********* UNSAT ***********
  
 1)NOTE: PLEASE SEE 210.52 FOR RECEPT
 SPACING IN BED RM #1, 2',6'12' RULE.
 6' OF DR.
  
 2)NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM MAIN TO PANEL.
 250.110, SIZE PER 250.122
  
 3)NOTE: PLEASE SEE ALL RECEPTS OUTSIDE
 TO BE SHOWN AS GFI/GFI PROTECTED.
 210.8
  
 4)NOTE: PLEASE SHOW DISC FOR COND UNIT
 PER 110.26. DISC SHOWN BEHIND UNIT.
  
 5)NOTE: PLEASE SEE RISER SHOWS A MAIN
 DISCONNECT, HOWEVER MAIN IS NOT SHOWN
 ON PLANS NEXT TO METER. PLEASE SHOW.
  
 6)NOTE : PLEASE SEE PANEL SCHEDULE
 INDICATES PANEL BEING MCB? PLEASE SEE
 RISER SHOWS A MAIN ON OUTSIDE ALSO.
 THIS IS PRMITTED,HOWEVER IF SHOWN ON
 PLANS THEN IT WOULD BE REQ'D TO BE
 INSTALLED.
 PLEASE ALSO SEE PANEL IS SHOWN AT 42CIR
 PLEASE VERIFY THIS # OF CIRCUITS FOR
 A 150A PANEL. PANEL SHOWS 42 AND RISER
 36.
  
 7)NOTE: PLEASE SEE SOME FIXTURES SHOWN
 ON PLANS DO NOT SEEM TO CORRELATE WITH
 FIXTURE SCHEDULE?
 PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 8)NOTE: ARC FAULT IS NOTED PER 210.12B,
 PLEASE INDICATE 2002 NEC/ ALL OUTLETS.
  
 9)NOTE: PLEASE SEE OCP FOR 2.5 TON CU.
 SHOWN AS 60A W/ #6'S. THIS SEEMS TO BE
 TOO HIGH FOR OCP.
  
 PLEASE SEE ON SET OF PLANS HAS REDLINES
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-08-18 Cont ID  
Sent By adarroug Date 2005-08-18 Time 17:32 Rev Time 0.00
Received By adarroug Date 2005-08-18 Time 17:32 Sent To B
Notes
2005-08-18 00:00:00TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-01-14 Cont ID  
Sent By mjacobs Date 2005-01-14 Time 15:38 Rev Time 0.00
Received By mjacobs Date 2005-01-14 Time 15:38 Sent To P
Notes
2005-01-14 00:00:00TO "P" BOX/REV.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-10-20 Cont ID  
Sent By csiegber Date 2004-10-20 Time 16:54 Rev Time 0.00
Received By csiegber Date 2004-10-20 Time 16:54 Sent To B
Notes
2004-10-20 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-12 Cont ID  
Sent By csiegber Date 2004-10-12 Time 16:43 Rev Time 0.00
Received By csiegber Date 2004-10-12 Time 16:43 Sent To B
Notes
2004-10-12 00:00:00TO RM DESK/

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-24 Cont ID  
Sent By csiegber Date 2004-09-24 Time 09:23 Rev Time 0.00
Received By csiegber Date 2004-09-24 Time 09:23 Sent To E
Notes
2004-09-24 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-03 Cont ID  
Sent By csiegber Date 2004-08-03 Time 13:45 Rev Time 0.00
Received By csiegber Date 2004-08-03 Time 13:45 Sent To E
Notes
2004-08-03 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-05-04 Time 15:07 Rev Time 0.00
Received By csiegber Date 2004-05-04 Time 15:07 Sent To E
Notes
2004-05-04 00:00:00TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-08-12 Cont ID  
Sent By pkrauss Date 2004-08-12 Time 11:36 Rev Time 0.35
Received By pkrauss Date 2004-08-12 Time 11:26 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-14 Cont ID  
Sent By kstevens Date 2004-08-12 Time 10:25 Rev Time 0.35
Received By pkrauss Date 2004-05-14 Time 11:04 Sent To P
Notes
2004-05-14 00:00:00DENIED:
 1.RETURN AIR TO THE MASTER BEDROOM IS
 NOT SIZED PROPERLY.REFERENCE THE
 REVISED 2001 FBC(M) 601.4 EXCEPTION #1 &
 RETURN TO THE MASTER SUITE SHOULD BE 12"
 NOT 9".
  
 2.PLEASE INDICATE SIZE OF SUPPLY DUCT
 TO BEDROOM #2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-02-05 Cont ID  
Sent By pschmitz Date 2005-02-05 Time 08:14 Rev Time 0.00
Received By pschmitz Date 2005-02-05 Time 08:15 Sent To B
Notes
2005-02-05 00:00:00WATER HEATER LOCATION

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-08-12 Cont ID  
Sent By kstevens Date 2004-08-12 Time 10:25 Rev Time 0.33
Received By kstevens Date 2004-08-12 Time 10:25 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-19 Cont ID  
Sent By dpalmer Date 2004-08-10 Time 15:21 Rev Time 0.50
Received By kstevens Date 2004-05-19 Time 14:44 Sent To  
Notes
2004-05-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P2.01 SANITARY RISER DIAGRAM. THE
 TRAPS FOR THE TUB ARE "S" TRAPS AS SHOWN
 AND ARE NOT ALLOWED PER SECTION 1002.3
 - ANY PORTION OF THE DRAINAGE SYSTEM IN-
 STALLED UNDERGROUND SHALL NOT BE LESS
 THAN 2". SECTION 710.3 - WASH MACHINE
 DRAIN REQUIRES A TRAP, STANDPIPE, AND
 A CLEANOUT. THE CLEANOUT SHALL BE MIN.
 4' ABOVE THE FLOOR FOR ACCESS. SEE SECT-
 IONS 1002.1, 802.4 & 708.10.
 2) 2" SHOWN TO WATER CLOSETS. SUBMIT
 MANUF. SPECIFICATION SHEETS INDICATING
 FIXTURE OUTLET SIZE. SEE FOOTNOTE D FOR
 TABLE 709.1.
 3) SEE RED LINE CORRECTIONS ON SHEET
 P2.01.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***