| Plan Review Stops For Permit 04050070 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
N |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-23 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-23 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2005-08-23 00:00:00 | SUBMITTED REVISED ENERGY CALCULATIONS. | | | CHANGED EXTERIOR FOIL FROM R-5 TO R-4.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-10 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-10 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2005-02-10 00:00:00 | REVISION TO CHANGE WOOD HEADERS AT | | | PORCHES TO POURED LINTELS IS DENIED. | | | REVISIONS TO MASTERED PLANS ARE NOT | | | ALLOWED AFTER MODELS ARE BUILT TO MATCH | | | THE ORIGINAL MASTERED PLAN. THIS IS THE | | | CASE PER CONVERSATION WITH THE | | | CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-02 |
Time |
15:41 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-11-02 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-13 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2004-10-13 00:00:00 | DENIED | | | | | | 1) THE TRUSS LAYOUT AND DRAWINGS ARE | | | REQUIRED TO BE REVIEWED AND APPROVED BY | | | THE ARCHITECT. THEY ARE TO BE STAMPED | | | AND SIGNED BY HIM AS BEING REVIEWED AND | | | ACCEPTED. | | | | | | 2) SHEET A2.01 IS MISSING FROM ONE OF | | | THE PLAN SETS. | | | | | | 3) THE STORM PANEL KEY PLAN AND SCHEDULE | | | INDICATE THAT THE EXTERIOR DOOR AT THE | | | KITCHEN IS TO BE SHUTTERED. THE PLANS | | | SHOW A METAL DOOR WITH NO GLAZING. | | | PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:43 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-10-08 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2004-10-08 00:00:00 | DENIED | | | | | | 1) THE VALUES LISTED IN THE TABLE FOR | | | THE USP THD28-2 CONNECTOR IN DETAIL 5 ON | | | S2.03 ARE INCORRECT. | | | | | | 2) THE STORM PANEL KEY/INSTALLATION | | | SCHEDULE INDICATES STORM PANELS ON THE | | | FRONT DOOR. THIS CONFLICTS WITH THE PLAN | | | AND PRODUCT APPROVAL WHICH SPECIFY AN | | | IMPACT RESISTANT GLAZED DOOR. PLEASE | | | CORRECT. | | | | | | 3) THE TRUSS LAYOUT AND DRAWINGS ARE | | | REQUIRED TO BE REVIEWED AND APPROVED BY | | | THE ARCHITECT. THEY ARE TO BE STAMPED | | | AND SIGNED BY HIM AS BEING REVIEWED AND | | | ACCEPTED. | | | | | | 4) THE ROOF FRAMING PLAN ON S2.03 DOES | | | NOT CLEARLY INDICATE THE UPLIFT AND | | | CONNECTORS FOR THE ALL FOUR BEARING | | | POINTS FOR TRUSSES A3, A4 AND A5. PLEASE | | | CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-17 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2004-08-17 00:00:00 | DENIED | | | | | | 1) THE ENERGY CALCULATIONS ARE REQUIRED | | | TO BE WORST CASE FOR MASTERED MODELS. | | | THE FORM IS REQUIRED TO BE SIGNED AND | | | DATED BY THE OWNER/AGENT. THE A/C AREA | | | ON THE PLANS AND ON THE ENERGY CALC. | | | FORMS DO NOT MATCH. | | | | | | 2) DETAIL #5 ON S2.03 IS INCORRECTLY | | | NUMBERED AS 201. THE THD28-2 DID NOT | | | GET CHANGED TO THE THDH28-2, WHICH HAS | | | THE UPLIFT OF 3185# THAT IS SPECIFIED. | | | | | | 3) SPECIFY ON SHEET S2.01 THAT THE | | | FINISH FLOOR OF THE MONOLITHIC SLAB IS | | | REQUIRED TO BE A MINIMUM OF 4" ABOVE | | | FINAL GRADE AT HABITABLE AREAS. SEE | | | CITY OF WPB AMENDMENTS TO FBC 1804.1.7. | | | | | | 4) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE INSTALLATION TYPE AND FASTENERS THAT | | | THE INSTALLATION TYPE AND FASTENERS THAT | | | WILL BE USED BY CIRCLING OR HIGHLIGHTING | | | THE ITEMS ON THE INSTALLATION DRAWINGS. | | | | | | 5) THE PRODUCT APPROVAL FOR THE PGT SH | | | 4000 WINDOWS DOES NOT MATCH THE NOA | | | NUMBERS ON THE MIAMI-DADE NOA THAT WAS | | | SUBMITTED. SUBMIT THE CORRECT NOA. | | | | | | 6) THE PRODUCT APPROVAL FOR THE PGT | | | FRENCH DOOR DOES NOT MATCH THE NOA | | | NUMBERS ON THE MIAMI-DADE NOA THAT WAS | | | SUBMITTED. SUBMIT THE CORRECT NOA. | | | | | | 7) THE TRUSS LAYOUT IS TO BE REVIEWED BY | | | THE ARCHITECT OF RECORD AND STAMPED AS | | | APPROVED BY HIM. | | | | | | 8) THE TRUSS LAYOUT AND TRUSS DRAWINGS | | | ARE REQUIRED TO HAVE THE ORIGIONAL WET | | | SIGNATURE OF THE TRUSS ENGINEER. SEE | | | FAC 61G15-23.002. | | | | | | 9) TRUSSES A3, A4, AND A5 HAVE FOUR | | | BEARING POINTS INDICATED ON THE TRUSS | | | DRAWINGS. THE ROOF FRAMING PLANS ONLY | | | SPECIFY CONNECTORS FOR THREE BEARING | | | POINTS. PLEASE CORRECT. | | | | | | 10) THE TRUSS LAYOUT NOTES THAT THE | | | BEAMS AT THE FRONT AND REAR PORCHES ARE | | | BY BUILDER. SHEET S2.03 OF THE PLANS | | | SPECIFY WOOD GIRDER TRUSSES. PLEASE | | | CORRECT. IF BEAMS ARE BY BUILDER PROVIDE | | | DETAILS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-12 |
Time |
11:36 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-06-03 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | DENIED | | | | | | 1) SUBMIT TRUSS DRAWINGS AND LAYOUT THAT | | | HAVE BEEN REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD. | | | | | | 2) THE ENERGY CALCS ARE REQUIRED TO BE | | | WORST CASE FOR THE MODEL. THE FORM IS | | | REQUIRED TO BE SIGNED AND DATED BY THE | | | OWNER AGENT. THE CONDITIONED FLOOR AREA | | | ON THE FORM AND THE PLANS SHOULD BE THE | | | SAME. | | | | | | 3) SPECIFY THE BOTTOM CORD LIVE LOAD ON | | | THE PLANS. SEE 2001 FBC TABLE 1604.1. | | | | | | 4) THE FLOOR PLAN ON A2.01 DOES NOT | | | CORRESPOND WITH THE REST OF THE PLANS. | | | SEE SOUTH ELEVATION AT BEDROOM 3. | | | | | | 5) THE FOOTING SHOWN IN THE WALL SECTION | | | ON S2.01 DOES NOT CORRESPOND WITH THE | | | FOOTING SCHEDULE. PLEASE CORRECT. | | | | | | 6) THE ISOLATED PAD DETAIL ON S2.01 IS | | | INCORRECTLY LABELED AS 7. IT SHOULD BE | | | 4. | | | | | | 7) THE TRUSS CONNECTOR IN THE WALL | | | SECTION ON S2.01 SHOULD BE USP. | | | | | | 8) SPECIFY THE MATERIAL USED FOR THE | | | CEILINGS (DIAPHRAGM) OF THE COVERED | | | PORCHES. | | | | | | 9) SUBMIT STATE PRODUCT APPROVALS FOR | | | THE USP CONNECTORS. | | | | | | 10) THE USP THD28-2 HAS A MAXIMUM UPLIFT | | | OF 2390# AT 133% PER 2004 USP CATALOG. | | | PLEASE REVISE DETAIL 5 ON S2.03. | | | | | | 11)THE UPLIFT FOR THE ROOF TRUSS GIRDERS | | | AT THE LEFT SIDE ARE NOT SPECIFIED OR | | | ARE INCORRECT. SEE NOTES ON PLAN. | | | | | | 12) THE EXTERIOR WALLS AT THE REAR PORCH | | | ARE NOT SHOWN ON THE ROOF FRAMING PLAN | | | ON S2.03. | | | | | | 13) ON S3.01 THE WALL SHEATHING IS | | | SPECIFIED AS 15/32" IN ONE PLACE AND | | | 5/8" IN ANOTHER. PLEASE CLARIFY. | | | | | | 14) THE ROOF SHEATHING IS INCORRECTLY | | | SPECIFIED AS 15/32" ON SHEET S3.01. CITY | | | OF WPB AMENDMENTS TO FBC TABLE 2309.3A | | | REQUIRES SHEATHING TO BE A MINIMUM OF | | | 19/32". | | | | | | 15) CITY AMENDMENTS TO FBC TABLE 2306.1 | | | REQUIRES ROOF SHEATHING TO BE NAILED AT | | | 4"OC ON THE EDGES AND 6"OC INTERMEDIATE | | | IN ZONE 3, WHICH INCLUDES THE COORNERS | | | OF HIP ROOFS. PLEASE REVISE NOTES ON | | | S3.01. | | | | | | 16) PLEASE UPDATE THE ACI EDITIONS THAT | | | ARE SPECIFIED ON S3.01 TO 2002 EDITIONS | | | AS REFERENCED BY THE 2001 FBC CHAPTER 35 | | | SEE NOTES ON THE PLANS. | | | | | | 17) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE INSTALLATION TYPE AND FASTENERS THAT | | | WILL BE USED BY CIRCLING OR HIGHLIGHTING | | | APPROPRIATE ITEMS ON THE INSTALLATION | | | DRAWINGS. | | | | | | 18) SUBMIT STATE PRODUCT APPROVALS FOR | | | THE FOLLOWING ITEMS: | | | - SINGLE OUTSWING DOOR AT KITCHEN | | | - DOUBLE OUTSWING DOOR AT STORAGE | | | - ALUMINUM SOFFIT | | | - TRUSS CONNECTORS | | | | | | 19) ONE OF THE PRODUCT APPROVALS FOR THE | | | STORM PANELS IS MISSING THE INSTALLATION | | | DRAWINGS. | | | | | | THE FOLLOWING ITEMS WILL BE REQUIRED TO | | | BE SUBMITTED FOR EACH PERMIT APPLICATION | | | UNDER THE MASTER. | | | - NOTICE OF COMMENCEMENT | | | - PAID RECEIPT FOR COUNTY IMPACT FEES | | | AND PLANS STAMPED BY THE COUNTY | | | - TWO COPIES OF SURVEY | | | - TWO COPIES OF SUBSURFACE SOIL REPORT | | | PER FBC 1804.2.2 | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
06:24 |
Sent To |
B |
|
| Notes |
| 2004-10-05 00:00:00 | MASTER MODEL "B" |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-10 |
Time |
15:11 |
Sent To |
P |
|
| Notes |
| 2004-08-10 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE OUTLETS FOR KITCHEN | | | PENINSULAR/WALL AREA IS NOT CLEAR. | | | PENINSULAR IS REQ'D TO GFI RECEPT PER | | | 210.52C3, PLEASE ALSO SEE (C5) | | | | | | 2)NOTE: PLEASE SEE ADDED RECEPT FOR | | | COND UNIT TO BE INDICATED AS WP/GFI. | | | 210.8 AS ON SYMBOL SCHEDULE. | | | | | | 3)NOTE: PLEASE ALSO SEE RECEPT ADDED TO | | | KITCHEN COUNTER, TO BE SHOWN AS GFI/ | | | GFI PROTECTED PER 210.8A6 | | | | | | 4)NOTE: PLEASE SEE OCP WAS CORRECTED FOR | | | COND UNIT, HOWEVER LOAD IS SHOWN AT 10KW | | | , PLEASE SEE IF LOAD OFR COND UNIT IS | | | HIGHER THAN HEATING LOAD, THEN COND UNIT | | | LOAD IS FIGNURED IN LOAD CALCS. THIS | | | SEEMS TO BE A MISPRINT. | | | 2.5 TON CU LOAD IS MOST LIKELY NOT MORE | | | THAN HEAT LOAD. PLEASE VERIFY. | | | | | | 5)NOTE: PLEASE SEE GENERAL NOTES, NOTE | | | #3 LAST LINE STILL MENTIONS ARC-FAULT | | | FOR RECEPTS. PLEASE REMOVE DUE TO NEW | | | NOTE BEING ADDED BELOW THIS. | | | | | | PLEASE NOTE: THESE PLANS ARE ONLY IN FOR | | | "PLAN REVIEW" FOR A MASTER. THIS REQUIRE | | | 'S EVERY ITEM TO BE 100% CORRECT AND | | | NO REDLINES CAN BE DONE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
14:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-10 |
Time |
06:55 |
Sent To |
M |
|
| Notes |
| 2004-05-10 00:00:00 | ********* UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE 210.52 FOR RECEPT | | | SPACING IN BED RM #1, 2',6'12' RULE. | | | 6' OF DR. | | | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM MAIN TO PANEL. | | | 250.110, SIZE PER 250.122 | | | | | | 3)NOTE: PLEASE SEE ALL RECEPTS OUTSIDE | | | TO BE SHOWN AS GFI/GFI PROTECTED. | | | 210.8 | | | | | | 4)NOTE: PLEASE SHOW DISC FOR COND UNIT | | | PER 110.26. DISC SHOWN BEHIND UNIT. | | | | | | 5)NOTE: PLEASE SEE RISER SHOWS A MAIN | | | DISCONNECT, HOWEVER MAIN IS NOT SHOWN | | | ON PLANS NEXT TO METER. PLEASE SHOW. | | | | | | 6)NOTE : PLEASE SEE PANEL SCHEDULE | | | INDICATES PANEL BEING MCB? PLEASE SEE | | | RISER SHOWS A MAIN ON OUTSIDE ALSO. | | | THIS IS PRMITTED,HOWEVER IF SHOWN ON | | | PLANS THEN IT WOULD BE REQ'D TO BE | | | INSTALLED. | | | PLEASE ALSO SEE PANEL IS SHOWN AT 42CIR | | | PLEASE VERIFY THIS # OF CIRCUITS FOR | | | A 150A PANEL. PANEL SHOWS 42 AND RISER | | | 36. | | | | | | 7)NOTE: PLEASE SEE SOME FIXTURES SHOWN | | | ON PLANS DO NOT SEEM TO CORRELATE WITH | | | FIXTURE SCHEDULE? | | | PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 8)NOTE: ARC FAULT IS NOTED PER 210.12B, | | | PLEASE INDICATE 2002 NEC/ ALL OUTLETS. | | | | | | 9)NOTE: PLEASE SEE OCP FOR 2.5 TON CU. | | | SHOWN AS 60A W/ #6'S. THIS SEEMS TO BE | | | TOO HIGH FOR OCP. | | | | | | PLEASE SEE ON SET OF PLANS HAS REDLINES | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
17:32 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
15:38 |
Sent To |
P |
|
| Notes |
| 2005-01-14 00:00:00 | TO "P" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:54 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-12 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2004-10-12 00:00:00 | TO RM DESK/ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-24 |
Time |
09:23 |
Sent To |
E |
|
| Notes |
| 2004-09-24 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
13:45 |
Sent To |
E |
|
| Notes |
| 2004-08-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:07 |
Sent To |
E |
|
| Notes |
| 2004-05-04 00:00:00 | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-12 |
Time |
11:36 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-12 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-12 |
Time |
10:25 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-05-14 |
Time |
11:04 |
Sent To |
P |
|
| Notes |
| 2004-05-14 00:00:00 | DENIED: | | | 1.RETURN AIR TO THE MASTER BEDROOM IS | | | NOT SIZED PROPERLY.REFERENCE THE | | | REVISED 2001 FBC(M) 601.4 EXCEPTION #1 & | | | RETURN TO THE MASTER SUITE SHOULD BE 12" | | | NOT 9". | | | | | | 2.PLEASE INDICATE SIZE OF SUPPLY DUCT | | | TO BEDROOM #2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-02-05 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-02-05 |
Time |
08:15 |
Sent To |
B |
|
| Notes |
| 2005-02-05 00:00:00 | WATER HEATER LOCATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-12 |
Time |
10:25 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-08-12 |
Time |
10:25 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-10 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-19 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P2.01 SANITARY RISER DIAGRAM. THE | | | TRAPS FOR THE TUB ARE "S" TRAPS AS SHOWN | | | AND ARE NOT ALLOWED PER SECTION 1002.3 | | | - ANY PORTION OF THE DRAINAGE SYSTEM IN- | | | STALLED UNDERGROUND SHALL NOT BE LESS | | | THAN 2". SECTION 710.3 - WASH MACHINE | | | DRAIN REQUIRES A TRAP, STANDPIPE, AND | | | A CLEANOUT. THE CLEANOUT SHALL BE MIN. | | | 4' ABOVE THE FLOOR FOR ACCESS. SEE SECT- | | | IONS 1002.1, 802.4 & 708.10. | | | 2) 2" SHOWN TO WATER CLOSETS. SUBMIT | | | MANUF. SPECIFICATION SHEETS INDICATING | | | FIXTURE OUTLET SIZE. SEE FOOTNOTE D FOR | | | TABLE 709.1. | | | 3) SEE RED LINE CORRECTIONS ON SHEET | | | P2.01. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|