Plan Review Details - Permit 04042053
Plan Review Stops For Permit 04042053
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By pschmitz Date 2004-05-12 Time 10:34 Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-05-04 Time 09:03 Rev Time 0.25
Received By dpalmer Date 2004-05-05 Time 17:21 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-05-04 Time 09:03 Rev Time 0.00
Received By csiegber Date 2004-05-04 Time 09:03 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-30 Cont ID  
Sent By mmclean Date 2004-05-03 Time 09:40 Rev Time 0.00
Received By csiegber Date 2004-04-30 Time 16:30 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-12 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 17:21 Rev Time 1.50
Received By pschmitz Date 2004-05-11 Time 09:43 Sent To B
Notes
2004-05-11 00:00:00PLUMBING PLAN REVIEW, DENIED.FBC 2001
  
 1) PLEASE ADJUST YOUR NOTES, DETAILS, OF
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 (2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 3) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND
 LINTSTRAINER WHEN USED WITH A PRESSURE
 FIL- TER. (DETAIL OR ADD TO NOTES)
 (4)FS 471.023, FAC 61G15-23.002
 NOTE: PLEASE NOTE, ALL PLANS DRAWN
 BY AN ARCHITECT/ENGINEER CONTAIN-
 -ING A TITLE BLOCK: MUST BE SIGNED,
 DATED AND SEALD BY THAT ARCH/ENG.
 PER FS 481.221 471.025
 (5) SEC 104.6.5 BUILDING PERMIT VALUE.
 BASED ON TOTAL REPLACEMENT VALUE, TO
 INCLUDE STRUCTAL,ELECTRIC,PLUMBING,MECH-
 ANICAL,INTERIOR FINISH,NORMAL SITE WORK.
 ARCHITECTURAL,DESIGN FEES,AND PROFIT.
 EXCLUDING ONLY LAND VALUE.
 (6) SEC 424.2.12.1 PRESSURE TEST.
 PER MANFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS.
 (7) SEC 424.2.13.2 JOINTS, CONNECTIONS,
 FBC SEC 605.21, PURPLE PRIMER REQUIRED
 ON PVC PIPING.
 END OF COMMENTS QUESTIONS 561-805-6692

Review Stop Z ZONING
Rev No 1 Status P Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-04-30 Time 16:30 Rev Time 0.00
Received By mmclean Date 2004-05-03 Time 09:40 Sent To I
Notes
***NONE***