| Plan Review Stops For Permit 04042035 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-06-24 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-06-24 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-05-24 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-05-24 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) FBC 704.3.1 & 1004.1.4(2)SHEET A-1, | | | FLOOR PLAN.THE NEW SECTIONS OF TENANT | | | WALL AT CORRIDOR NORTH AND CORRIDOR | | | EAST SHALL BE ONE-HOUR FIRE-RATED. | | | AMEND THE PLAN. | | | | | | 3) FBC 704.3.1 & 1004.1.4(2)SHEET A-2, | | | DETAIL 6.WHAT IS THE U.L. LISTING | | | REFERENCE FOR THE HORIZONTAL SHAFT WALL? | | | ANNOTATE THE PLANS. | | | | | | 4) FBC TABLE 705.1.2SHEET A-1, DOOR | | | SCHEDULE.DOOR 611 SHALL HAVE A FIRE | | | RESISTANCE RATING OF 20MINUTES.AMEND | | | THE SCHEDULE. | | | | | | 5) FBC 11-4.24SHEET A-1, LOUNGE SINK | | | DEPTH AND KNEE CLEARANCE.IT IS NOTED | | | THAT DETAIL 3 SHOWS 'NO BASE' FOR THE | | | UNDER-SINK CABINET.THE SINK SHALL BE A | | | MAXIMUM OF 6-1/2" DEEP AND THE KNEE | | | CLEARANCE UNDER THE SINK SHALL BE AT | | | LEAST 27" HIGH, 30" WIDE AND 19" DEEP. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE. | | | | | | 6) FBC 2405.2SHEET A-1. THE GLAZING | | | SHOWN IN THE ELEVATIONAL VIEW OF DOOR | | | TYPE C IS NOT REFERENCED IN THE DOOR | | | SCHEDULE, FOR DOOR #603.THE GLAZING | | | IS IN A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 7) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-09 |
Time |
09:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-09 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
16:33 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-08 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-15 |
Time |
17:26 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-15 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | ******* UNSAT ******** | | | | | | NEW COMMENT: | | | | | | 1)NOTE: PLEASE SEE PLANS/TITLE BLOCK | | | CONTAIN CERTIFICATE OF AUTHORIZATION # | | | FOR ANOTHER FIRM. THIS NEEDS TO CORRE- | | | -LATE WITH STATE CA #. | | | PLEASE SEE COPY OF DBPR WEB SITE SHOWING | | | # TO DIFFERENT FIRM. | | | (MISPRINT OF OLD #?) | | | | | | THIS IS FOR ALL P | | | | | | ELEC OK. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
18:37 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | **********UNSAT ***************** | | | | | | 1) NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42,210.19A,210.20A ETC | | | | | | 2)NOTE: PLEASE 250.30 FOR GROUNDING | | | OF TRANSFORMER. PLEASE SHOW ATTACHMENT(S | | | | | | 3)NOTE: PLEASE CLARIFY ELECTRICAL ROOM | | | SHOWS ELEVATED BUS DUCT WITH DISC AT THE | | | SAME LOCATION. PLEASE SEE RISER DIAGRAM, | | | INDICATES DISCONNECT UNDER METER? | | | PLEASE CORRELATE PLANS/W/ RISER | | | | | | 4)NOTE: PLEASE VERIFY 1/0 CONDUCTORS | | | SHOWN FOR 70A FEED TO TRANSFORMER. | | | 1/0'S ARE PERMITTED, HOWEVER, PLEASE | | | VERIFY IF THIS SIZE CONDUCTOR WILL FIT | | | INTO 70A BRKR? THIS IS A CLARIFICATION | | | NOTE ONLY.. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-07-12 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-07-12 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-06-08 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-06-08 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-30 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-30 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) IN THE DOOR SCHEDULE REMARKS NONE | | | ARE MADE FOR DOOR 611. ANY REASON FOR | | | THIS DOOR NOT TO BE FIRE RATED. | | | | | | 3) IT APPEARS THAT DOOR 625 DOES NOT | | | NEED TO BE FIRE RATED. THE DOOR | | | SCHEDULE INDICATES THAT IT IS. PLEASE | | | EXPLAIN. | | | | | | 4) KEY NOTES ON PAGE A-1 INDICATES | | | # 8, CARD READER FOR ENTRY AND EXIT | | | PLEASE EXPLAIN FURTHER. | | | | | | 5) SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER SYSTEM | | | REMODEL. | | | | | | 6) SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE ALARM SYSTEM | | | REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
| 2004-08-03 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-02 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-02 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | TO COMM BD#35 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2004-06-07 00:00:00 | TO COMM BD#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-27 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-04-30 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | TO COMM BD#16 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-12 |
Time |
10:06 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-12 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | NEW MECHANICAL SHEETS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-13 |
Time |
07:54 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-13 |
Time |
07:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-14 |
Time |
16:11 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-07-14 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2004-07-14 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTOR SHALL BE INSTALLED | | | PER PDI-WH 201 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-19 |
Time |
07:24 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-19 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2004-06-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: SHT A-1 DETAIL | | | #3 SHOW COMPLIANCE FOR SECTION 11-4.24.6 | | | EXPOSED PIPES AND SURFACES ON PLANS. | | | 2) FROM PREVIOUS REVIEW: SHT PO.1 DOMES- | | | TIC WATER ISOMETRIC, THE WATER HAMMER | | | ARRESTOR SHALL BE LOCATED NEAR THE FIX- | | | TURE NOT IN THE CEILING AS SHOWN. PDI-WH | | | 201 AND MANUF. INSTALLATION INSTRUCTIONS | | | 3) CORRECT THE CERTIFICATE OF AUTHORIZ- | | | ATION NUMBER REQUIRED BY 61G15-23.002(2) | | | AND FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-27 |
Time |
09:52 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-27 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2004-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 DETAIL DETAIL #3 AND FLOOR | | | PLAN. SHOW KNEE CLEARANCEPER SECTION | | | 114.24.3, SINK DEPTH 11-4.24.4, CLEAR | | | FLOOR SPACE 11-4.24.5, AND EXPOSED PIPES | | | AND SURFACES 11-4.24.6 | | | 2) SHT P0.1 DOMESTIC WATER ISOMETRIC, | | | THE WATER HAMMER ARRESTOR SHALL BE LOC- | | | ATED NEAR THE FIXTURE NOT IN THE CEILING | | | AS SHOWN. PDI-WH 201 & MANUF. INSTALL, | | | INSTRUCTIONS | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|