Plan Review Details - Permit 04041996
| Plan Review Stops For Permit 04041996 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-17 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-05-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
11:08 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-05-14 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | DENIED | | | 1015.2 HEIGHT. GUARDRAILS SHALL | | | FORM A VERTICAL PROTECTIVE BARRIER NOT | | | LESS THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | | REJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE. | | | SHOW DETAILS, AND METHOD OF FASTENING. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-17 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
| 2004-05-17 00:00:00 | TO AL DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-10 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-10 |
Time |
07:43 |
Sent To |
B |
|
| Notes |
| 2004-05-10 00:00:00 | TO MISC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-07 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-06 |
Time |
11:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
08:20 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-07 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-07 |
Time |
11:26 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-06 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-05 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | DENIED, NEED TO PROVIDE TWO COPY OF | | | SURVEY SHOWING THE WORK.CALLLED CONTR | | | FILE FOR P/U B |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |