| Plan Review Stops For Permit 04041979 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-06-30 |
Time |
10:54 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-06-30 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-05-20 |
Time |
13:42 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-05-20 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | SEE ELEC. & PLUMB. NOTES RGARDING | | | ARCHITECT TITLE BLOCK & SIGNATURE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLAN EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-02 |
Time |
08:29 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-01 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | REDLINED 210.62 RECEPTS REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-09 |
Time |
17:16 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-06-09 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2004-06-09 00:00:00 | ************** UNSAT ***************** | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | NOT ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE FS 471.219 AND FAC | | | 61G1-16.004 WHICH REQUIRES ALL LICENSE | | | #'S TO BE PRINTED ON TITLE BLOCK. | | | PREVIOUS PLANS WERE SENT OFF TO STATE | | | DBPR FOR THIS AND PLANS STILL DO NOT | | | INCLUDE #'S.?? | | | | | | 2)NOTE: PLEASE CLARIFY SHOW WINDOW | | | RECEPTS. PLANS NOW SHOW REQUIRED RECEPTS | | | TO BE REMOVED? PLEASE SEE 210.62. THESE | | | ARE REQUIRED. | | | | | | 3)NOTE: PLEASE ALSO SEE 600.5. PANEL | | | SCHEDULE SHOWS REQUIRED SIGN CIRCUIT TO | | | BE REMOVED? THIS IS REQUIRED. | | | | | | PLEASE SEE NOTE #1, THIS IS REQ'D FOR | | | ALL SHEETS AND PLANS. PLEASE SEE ONE SET | | | OF PLANS ARE BEING RETAINED FOR FILE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
19:17 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
19:17 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: PLEASE CLARIFY IF NEW OR EXIST- | | | -ING SIGN CIRCUIT? 600.5 | | | | | | 2)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | | -ING OF EM/EXT LTS. | | | TO BE ON SAME BRANCH CIRCUIT SUPPLYING | | | GEN LT IN AREA. | | | | | | 3)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE. | | | | | | 4) NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42,210.19A,210.20A ETC | | | PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER2002 NEC COMMERCIAL BLD | | | 220.3,220.10,220.11,220.13 ETC. | | | RESIDENTIAL LOAD CALC SHOWN. | | | PLEASE ALSO SEE LOAD CALCS INDICATE | | | 26 FIXTURES @180 VA?? PLEASE VERIFY?? | | | | | | 5)NOTE: PLEASE SEE PANEL SCHEDULE, | | | SHOWS PANEL AS BEING MLO AND MCB??? | | | PLEASE CLARIFY. | | | | | | 6)NOTE: PLEASE SEE FAC 61G1-16.004, | | | PLEASE PROVIDE ALL LICENSE #'S ON TITLE | | | BLOCK. PLEASE ALSO SEE FS 481.219 FOR | | | REQ'D CA #. ALSO REQ'D ON TITLE BLOCK. | | | PLEASE SEE FS 481.221 WHICH REQ'S A | | | SIGNATURE, DATE AND SEAL. | | | PLEASE PROVIDE A COPY OF | | | LICENSE/ TO VERIFY LEGAL SIGNATURE FOR | | | FILE. DBPR/ FBPE'S, INITIALS ARE NOT | | | PERMITTED. | | | | | | 7)NOTE: PLANS SHOW "J" BOXES FOR REQ'D | | | EGRESS LIGHTING. PLEASE VERIFY SOME SORT | | | OF FIXTURE FOR MIN EGRESS LIGHTING WILL | | | BE REQ'D. LS101 5-8 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-30 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-30 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | 1) PORTABLE FIRE EXTINGUISHER REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-29 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-29 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | TO COMM BD#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-04 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-04 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2004-06-04 00:00:00 | TO COMM BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-04 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | TO COMM BD#46 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-05-20 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-14 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-14 |
Time |
17:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-18 |
Time |
17:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-18 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A) FIRM LICENSE NUMBER NOT ON THE TITLE | | | BLOCK AS REQUIRED BY FAC 61G1-16.004(4) | | | (6) & FS 481.2055. - THIS COMMENT IS | | | FROM THE PREVIOUS REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-17 |
Time |
08:29 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-17 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT A-1.0 SANT. PLUMBING RISER DIAG. | | | THE WASH MACHINE SHALL NOT DRAIN THROUGH | | | THE WET VENT FOR THE BATHROOM FIXTURES. | | | THE WASH MACHINE SHALL DISCHARGE DOWN- | | | STREAM OF THE BATHROOM FIXTURES. SECTION | | | 909.1 | | | 2) THE SINK SHALL COMPLY WITH SECTION | | | 11-4.24 AND ALL SUBSECTIONS. SUBMIT A | | | DETAIL. | | | 3) THE PERSONAL SIGNATURE AND DATE OF | | | THE ARCHITECT SHALL APPEAR ON ALL ARCHIT | | | ECTURAL DOCUMENTS TO BE FILED FOR PUBLIC | | | RECORD. INITIALS ARE NOT ACCEPTABLE. | | | MUST BE AT LEAST A FIRST AND LAST NAME | | | AS SHOWN ON ARCH. LICENSE. FAC 61G1-16. | | | 003 & FS 481.2055 | | | 4) FIRM LICENSE AND PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT ARE REQUIRED | | | ON TITLE BLOCK. FAC 61G1-16.004(2)(6) & | | | FS481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|