Plan Review Details - Permit 04041956
Plan Review Stops For Permit 04041956
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2004-08-20 Cont ID  
Sent By pkrauss Date 2004-08-19 Time 13:09 Rev Time 0.00
Received By alange Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-05-14 Cont ID  
Sent By pkrauss Date 2004-05-11 Time 15:37 Rev Time 1.25
Received By alange Date 2004-05-14 Time 13:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2004-10-28 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 13:54 Rev Time 1.00
Received By dpalmer Date 2004-10-28 Time 13:54 Sent To P
Notes
2004-10-28 00:00:00NEW RISER W/ NEW SERVICE REVISED.

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2004-10-06 Cont ID  
Sent By csiegber Date 2004-10-27 Time 09:50 Rev Time 0.33
Received By dpalmer Date 2004-10-06 Time 19:59 Sent To P
Notes
2004-10-06 00:00:00********* UNSAT ***********
  
 1)NOTE: PLEASE SEE PLANS ARE NOW BEING
 SUBMITTED WITH A COMPLETELY NEW RISER
 DIAGRAM SHOWN???
 PLEASE SEE PLANS/FLOOR LAYOUT STILL SHOW
 'S METER/MAIN COMBO AS SHOWN ON PREVIOUS
 PLANS YET THIS DOES NOT CORRELATE WITH
 NEW RISER?
 PLEASE SEE MAINS ARE NOT NOT GROUPED AS
 REQUIRED PER 230.72??
  
 2)NOTE:PLEASE ALSO SEE EQUIPMENT GROUND-
 -ING CONDUCTORS ARE NOW BEING SHOWN
 BEFORE THE FIRST MEANS OF DISCONNECT.
 PLEASE SEE 250.6, 250.24 EQUIPMENT
 GROUNDING IS ONLY INSTALLED AFTER THE
 FIRST MEANS OF DISCONNECT.
  
 3)NOTE: PLEASE SEE 61G1-16.004 FOR
 ALL INFORMATION REQUIRED TO BE PRINTED
 ON TITLE BLOCK AS NOTED ON PREVIOUS
 REVIEW.
  
 **PLEASE SEE ONE SET OF EACH PLANS ARE
 NOW BEING RETAINED FOR FILE,AND POSSIBLE
 REVIEW BY THE BOARD OF ARCHITECTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2004-09-01 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:28 Rev Time 0.25
Received By dpalmer Date 2004-09-01 Time 15:51 Sent To P
Notes
2004-09-01 00:00:00*********** UNSAT ***************
  
 1)NOTE: PLEASE SEE MISSING GROUNDING
 SYSTEM AT DETACHED BLDG.
 NEC 250.32
  
 2)NOTE: PLEASE SEE MAIN HOUSE GROUNDING
 ELECTRODE SYSTEM SHOWS FOUN STEEL AGAIN.
 PLEASE VERIFY THIS FOR EXISTING DWELL-
 -ING?
 250.50
 NOT REQUIRED UNLESS SHOWN ON PLANS.
 INFORMATION WE WERE GIVEN, THIS IS AN
 EXSITING HOUSE.
  
 3)NOTE: PLEASE SEE FAC 61G1-16.004 FOR
 MISSING INFORMATION ON TITLE BLOCK.
  
 4)NOTE: PLEASE SEE WHITE-OUT ON PLANS
 ARE NOT PERMITTED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-08-19 Cont ID  
Sent By csiegber Date 2004-08-30 Time 09:23 Rev Time 0.75
Received By dpalmer Date 2004-08-19 Time 10:31 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-08-03 Cont ID  
Sent By csiegber Date 2004-08-16 Time 11:50 Rev Time 0.75
Received By dpalmer Date 2004-08-03 Time 16:47 Sent To P
Notes
2004-08-03 00:00:00*********** UNSAT 3RD REVIEW **********
  
 PLEASE SEE SOME NOTES FROM PREVIOUS
 HAVE NOT BEEN ADDRESSED.
  
 1)NOTE: PLEASE SEE PERMIT APPLICATION
 STILL ONLY REFERENCE ADDITION OF NEW
 BATH??
  
 2)NOTE: PLEASE SEE 210.52E PLANS STILL
 MISSING FRONT AND REAR RECEPTS.
  
 3)NOTE: PLEASE SEE DETACHED BLDG IS
 STILL MISSING REQUIRED GRND ROD AND CWP
 FOR GROUNDING PER 250.32.
  
 4)NOTE: PLEASE SEE GARAGE IS STILL
 MISSING REQUIRED GFI RECEPT PER 210.52G
 GARAGE NOW APPEARS TO HAVE A RECEPT
 ADDED FOR GDO, YET PANEL SCHEDULE DOES
 NOT REFLECT THIS?? REQUIRED TO BE A
 DEDICATED CIRCUIT.
  
 NEW COMMENTS DUE TO CHANGES IN PLANS
 ONCE MORE.
  
 1)NOTE: PLEASE SEE MAIN HOUSE GROUNDING
 ELECTRODE SYSTEM IS NOW SHOWING FOOTER
 STEEL FOR AN ATTACHMENT ON AN EXISTING
 BLDG. PLEASE SEE 250.50, GRND RODS WILL
 BE REQUIRED.
  
 2)NOTE: PLEASE SEE THE WATER HEATER
 WHICH WAS IN MAIN HOUSE ON PREVIOUS
 REVIEWS, HAS NOW BEEN MOVED TO DETACHED
 BLDG. PLEASE SEE WATER HEATER IS STILL
 SHOWN ON MAIN HOUSE PANEL SCHEDULE AND
 NOT ON PANEL AT DETACHED BLDG.
  
  
 PLEASE SEE NOTICE WAS GIVEN ON PREVIOUS
 REVIEW IN REFERENCE TO FS 553.80(2)(B)
 WITH RESPECT TO DESIGN PROFESSIONAL.
 A 4X FEE HAS NOW BEEN ACCESSED DUE TO
 CODE COMPLIANCE COMMENTS BEING REPEATED
 ON THE REVIEWS 3 OR MORE TIMES.
 BZ 244396 $240.00
 THIS FEE IS REQUIRED TO BE PAID BEFORE
 PLANS MAY BE RE-SUBMITTED.
 ONE COPY OF EACH ELECTRICAL PLAN HAS NOW
 BEEN RETAINED FOR FILE AND POSSIBLE
 FURTHER ACTION TO BE TAKEN UP WITH
 THE BOARD.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-06-22 Cont ID  
Sent By dpalmer Date 2004-06-22 Time 14:12 Rev Time 1.00
Received By dpalmer Date 2004-06-22 Time 14:12 Sent To P
Notes
2004-06-22 00:00:00*********** UNSAT *****************
  
 PLEASE SEE SOME NOTES AND REDLINED ITEMS
 FROM FIRST REVIEW WERE NOT ADDRESSED.
 PLANS ALSO HAVE CHANGES MADE FROM FIRST
 SET OF PLANS THAT NOW HAVE COMMENTS.
  
 1)NOTE: PLEASE SEE APPLICATION STILL
 CALLS OUT FOR REMODEL OF BATH?
 PLAN SHOWS COMPLETE REWIRE?
  
 2)NOTE: PLEASE SEE 250.32 FOR GROUNDING
 AT DETACHED BLDG.
  
 3)NOTE: PLEASE SEE SOME CONDUITS ARE
 \STILL MISSING EQUIPMENT GROUNDING
 CONDUCTORS. 250.110,250.122
 PLEASE NOW SEE AN EQUIPMENT GRND HAS
 BEEN ADDED TO RISE AHEAD OF METER AND
 FROM METER TO THE FIRST MEANS OF DISC.
 PLEASE SEE 250.24,250.6. THIS SHALL NOT
 BE INSTALLED.
  
 4)NOTE: PANEL AT MAIN HOUSE IS NOW BEING
 SHOWN AS "MCO"?PLEASE ALSO SEE WHAT
 APPEARS TO BE A MAIN DISC BEING ADDED
 AHEAD OF 200A PANEL?
 PLEASE SHOW ON PLANS AND CLARIFY IF
 PANEL IS NOW A "MLO" W/ A MAIN DISC
 OUTSIDE.? 215.5
  
 5)NOTE: PLEASE SEE SD'S STILL MISSING
 AT DEATCHED BLDG. THIS IS CONSIDERED
 AN ADAPTABLE SLEEPING AREA. SD'S ARE
 REQUIRED INSIDE AND OUTSIDE ROOM.
  
 6)NOTE: PLEASE SEE ORIG PLAN WAS RED-
 -LINED FOR 210.52E FOR MISSING FRONT AND
 REAR RECEPT(S).
  
 7)NOTE:PLEASE SEE KW RATING FOR A/C UNIT
 HAS NOW CHANGED TO 10KW. HOWEVER OCP
 HAS NOW DROPPED BACK DOWN TO 40A'S?
 PLEASE SEE 424.3B MIN 125%.
 PLEASE ALSO SEE AWG HAS NOW CHANGED FROM
 THE REQUIRED #6 AS SHOWN ON ORIG PLANS
 TO #8?310.16
  
 8)NOTE: PLEASE SEE PANEL SCHEDULE NOW
 HAS BEEN CHANGED TO SHOW SUB-FEEDERS AS
 #8'S, YET RISER STILL IS SHOWING #6'S.
 PLEASE CORRELATE.
  
 9)NOTE: PLEASE SEE RISER DIAGRAM NOW
 SHOWS OCP FOR A/C AHU. SHOWN AS 60A DISC
 W/30A OCP>?? PLEASE SEE NOTE 7).
 424.3B. 10KW. CONDUCTORS ON RISER HAVE
 NOW CHANGED ALSO.
  
 10)NOTE: PLEASE SEE PLANS SHOW A 50A
 DISC AT DETACHED BLDG AND RISER INDICATE
 -S 60A? PLEASE CORRELATE.
  
 11)NOTE: PLEASE SEE MISSING RECEPT IN
 GARAGE PER 210.52G AND RECEPT FOR 2'
 OF WALL IN MIDDLE BEDRM. 210.52
 NEW NOTE.
  
 12)NOTE: PLEASE SEE COPY OF FS 553.80(2)
 (B) ATTACHED. THIS IS A NOTICE GIVEN
 WITH RESPECT TO DESIGN PROFESSIONAL.
 THIS IS ONLY A NOTICEAT THIS TIME.
  
 PLEASE TAKE OUT AND REMOVE ALL OLD/
 VOIDED SHEETS. PLEASE ONLY INSERT NEW
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. ONE SET OF OLD SHEETS
 MAY BE SUBMITTED FOR REFERENCE ONLY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-06-17 Time 15:16 Rev Time 0.75
Received By dpalmer Date 2004-05-04 Time 13:15 Sent To P
Notes
2004-05-04 00:00:00*************** UNSAT *************
  
 1)NOTE: PLEASE SEE APPLICATION WAS
 SUBMITTED FOR REMODEL OF BATH YET PLANS
 SHOW COMPLETE REMOD FOR ELECTRICAL ??
 PLEASE CLARIFY.???
  
 2)NOTE: PLEASE SEE FAC 61G1-16.004 FOR
 ALL LICENSE #'S REQ'D ON TITLE BLOCK.
 PLEASE ALSO SEE FS 481.219 FOR REQ'D
 CERTIFICATE OF AUTHORIZATION #.
 THIS IS FOR ALL TRADES AND ALL SHEETS
 WEATHER OR NOT COMMENT IS MADE FROM
 OTHER REVIEWERS.
  
 REVIEW FOR ELECTRICAL CODE COMPLIANCE
 FOR NEW ELECTRICAL AS SHOWN.
  
 1)NOTE: PLEASE SHOW ALL A/C EQUIPMENT
 AND DISC'S PER 440.11, RECEPTS PER
 210.63/ 210.70
  
 2)NOTE: PLEASE SEE 220 FOR LOAD CALCU-
 -LATIONS. PLEASE SEE 220.16, 220.18
  
 3)NOTE: PLEASE SEE NFPA-72 FOR REQ'D
 SD'S MISSING.
  
 4)NOTE: PLEASE SEE 210.8A6 FOR GFI
 PROTECTION REQ'D.
  
 5)NOTE: PLEASE SEE 424.3B FOR OCP
 SHOWN FOR AHU. 60A FOR 5KW??
  
 6)NOTE: PLEASE SEE 225.31,250.32 FOR
 DETACHED BLDG.
  
 7)NOTE: PLEASE SEE 250.110, 250.122 FOR
 MISSING EQUIPMENT GROUNDING CONDUCTORS
 ON RISER DIAGRAM.
  
 8)NOTE: PLEASE VERIFY COMPLIANCE W/
 230.70 FOR MORE THAN 8' OF UNPROTECTED
 CONDUCTORS INSIDE HOUSE FROM METER?
  
 9)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 10)NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 210.12, 2002 NEC
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-10-27 Cont ID  
Sent By csiegber Date 2004-10-27 Time 09:50 Rev Time 0.00
Received By csiegber Date 2004-10-27 Time 09:50 Sent To E
Notes
2004-10-27 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:28 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 15:28 Sent To E
Notes
2004-10-05 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 09:22 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 09:22 Sent To E
Notes
2004-08-30 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-16 Time 11:50 Rev Time 0.00
Received By csiegber Date 2004-08-16 Time 11:49 Sent To E
Notes
2004-08-16 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 16:24 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 16:24 Sent To  
Notes
2004-07-29 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-17 Cont ID  
Sent By csiegber Date 2004-06-17 Time 15:15 Rev Time 0.00
Received By csiegber Date 2004-06-17 Time 15:15 Sent To E
Notes
2004-06-17 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-28 Cont ID  
Sent By csiegber Date 2004-04-28 Time 16:03 Rev Time 0.00
Received By csiegber Date 2004-04-28 Time 16:03 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2004-08-19 Cont ID  
Sent By pkrauss Date 2004-08-19 Time 13:09 Rev Time 0.15
Received By pkrauss Date 2004-08-19 Time 13:09 Sent To B
Notes
2004-08-19 00:00:00MECHANCIAL PLANS SUBMITTED WITH MECH
 APPLICATION #04070786, SEPARATELY.NO
 MECHANICAL WORK UNDER THIS PERMIT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-07-07 Cont ID  
Sent By dpalmer Date 2004-08-19 Time 11:08 Rev Time 0.35
Received By pkrauss Date 2004-07-07 Time 11:51 Sent To  
Notes
2004-07-07 00:00:00DENIED:
 PLANS ARE NOT IN COMPLIANCE WITH FS
 471.025 & FAC 61G15-23.002, PLANS ARE
 TO BE SIGNED NOT INTITIALED BY THE
 ENGINEER.ONE SET OF PLANS WILL BE
 FORWARDED TO DBPR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-05-11 Cont ID  
Sent By pschmitz Date 2004-05-09 Time 15:56 Rev Time 0.15
Received By pkrauss Date 2004-05-11 Time 15:33 Sent To B
Notes
2004-05-11 00:00:00NO MECHANICAL PLANS OR INFORMATION
 SUBMITTED WITH PERMIT APPLICATION.
 PLEASE PROVIDE PLANS WITH MECHANICAL
 PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-11-03 Cont ID  
Sent By kstevens Date 2004-11-03 Time 14:27 Rev Time 0.50
Received By kstevens Date 2004-11-03 Time 14:27 Sent To  
Notes
2004-11-03 00:00:00REVISION OK

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-10-23 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 13:59 Rev Time 0.50
Received By kstevens Date 2004-10-22 Time 18:56 Sent To  
Notes
2004-10-23 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FAC 61G1-16.004 - FS481.2055 MISSING IN-
 FORMATION ON TITLE BLOCK REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-09-18 Cont ID  
Sent By dpalmer Date 2004-10-06 Time 20:06 Rev Time 0.75
Received By jleech Date 2004-09-18 Time 08:27 Sent To  
Notes
2004-09-18 00:00:00DENIED;
 1.FLOOR PLAN ON SHT. A-3 DOES NOT SHOW
 WASHER AND L/T. PLUMBING FIXTURES ONLY
 SHOWN ON SHEET A-4. SHOW HOW WASHER
 AND L/T ARE TO BE PIPED ON RISER
 DIAGRAM.
 2.RISER DIAGRAM FOR MAIN HOUSE. SHOW HOW
 BATHROOM IS TIED INTO THE PLUMBING
 SYSTEM.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-09 Cont ID  
Sent By dpalmer Date 2004-09-01 Time 15:57 Rev Time 1.00
Received By pschmitz Date   Time   Sent To M
Notes
2004-05-09 00:00:00PROVISO:
 SUBJECT TO FIELD INSPECTOR,PES