| Plan Review Stops For Permit 04041956 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-19 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-11 |
Time |
15:37 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-05-14 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-28 |
Time |
13:54 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-10-28 |
Time |
13:54 |
Sent To |
P |
|
| Notes |
| 2004-10-28 00:00:00 | NEW RISER W/ NEW SERVICE REVISED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-27 |
Time |
09:50 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-06 |
Time |
19:59 |
Sent To |
P |
|
| Notes |
| 2004-10-06 00:00:00 | ********* UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE NOW BEING | | | SUBMITTED WITH A COMPLETELY NEW RISER | | | DIAGRAM SHOWN??? | | | PLEASE SEE PLANS/FLOOR LAYOUT STILL SHOW | | | 'S METER/MAIN COMBO AS SHOWN ON PREVIOUS | | | PLANS YET THIS DOES NOT CORRELATE WITH | | | NEW RISER? | | | PLEASE SEE MAINS ARE NOT NOT GROUPED AS | | | REQUIRED PER 230.72?? | | | | | | 2)NOTE:PLEASE ALSO SEE EQUIPMENT GROUND- | | | -ING CONDUCTORS ARE NOW BEING SHOWN | | | BEFORE THE FIRST MEANS OF DISCONNECT. | | | PLEASE SEE 250.6, 250.24 EQUIPMENT | | | GROUNDING IS ONLY INSTALLED AFTER THE | | | FIRST MEANS OF DISCONNECT. | | | | | | 3)NOTE: PLEASE SEE 61G1-16.004 FOR | | | ALL INFORMATION REQUIRED TO BE PRINTED | | | ON TITLE BLOCK AS NOTED ON PREVIOUS | | | REVIEW. | | | | | | **PLEASE SEE ONE SET OF EACH PLANS ARE | | | NOW BEING RETAINED FOR FILE,AND POSSIBLE | | | REVIEW BY THE BOARD OF ARCHITECTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-01 |
Time |
15:51 |
Sent To |
P |
|
| Notes |
| 2004-09-01 00:00:00 | *********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE MISSING GROUNDING | | | SYSTEM AT DETACHED BLDG. | | | NEC 250.32 | | | | | | 2)NOTE: PLEASE SEE MAIN HOUSE GROUNDING | | | ELECTRODE SYSTEM SHOWS FOUN STEEL AGAIN. | | | PLEASE VERIFY THIS FOR EXISTING DWELL- | | | -ING? | | | 250.50 | | | NOT REQUIRED UNLESS SHOWN ON PLANS. | | | INFORMATION WE WERE GIVEN, THIS IS AN | | | EXSITING HOUSE. | | | | | | 3)NOTE: PLEASE SEE FAC 61G1-16.004 FOR | | | MISSING INFORMATION ON TITLE BLOCK. | | | | | | 4)NOTE: PLEASE SEE WHITE-OUT ON PLANS | | | ARE NOT PERMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:23 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-19 |
Time |
10:31 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
11:50 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
16:47 |
Sent To |
P |
|
| Notes |
| 2004-08-03 00:00:00 | *********** UNSAT 3RD REVIEW ********** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | HAVE NOT BEEN ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION | | | STILL ONLY REFERENCE ADDITION OF NEW | | | BATH?? | | | | | | 2)NOTE: PLEASE SEE 210.52E PLANS STILL | | | MISSING FRONT AND REAR RECEPTS. | | | | | | 3)NOTE: PLEASE SEE DETACHED BLDG IS | | | STILL MISSING REQUIRED GRND ROD AND CWP | | | FOR GROUNDING PER 250.32. | | | | | | 4)NOTE: PLEASE SEE GARAGE IS STILL | | | MISSING REQUIRED GFI RECEPT PER 210.52G | | | GARAGE NOW APPEARS TO HAVE A RECEPT | | | ADDED FOR GDO, YET PANEL SCHEDULE DOES | | | NOT REFLECT THIS?? REQUIRED TO BE A | | | DEDICATED CIRCUIT. | | | | | | NEW COMMENTS DUE TO CHANGES IN PLANS | | | ONCE MORE. | | | | | | 1)NOTE: PLEASE SEE MAIN HOUSE GROUNDING | | | ELECTRODE SYSTEM IS NOW SHOWING FOOTER | | | STEEL FOR AN ATTACHMENT ON AN EXISTING | | | BLDG. PLEASE SEE 250.50, GRND RODS WILL | | | BE REQUIRED. | | | | | | 2)NOTE: PLEASE SEE THE WATER HEATER | | | WHICH WAS IN MAIN HOUSE ON PREVIOUS | | | REVIEWS, HAS NOW BEEN MOVED TO DETACHED | | | BLDG. PLEASE SEE WATER HEATER IS STILL | | | SHOWN ON MAIN HOUSE PANEL SCHEDULE AND | | | NOT ON PANEL AT DETACHED BLDG. | | | | | | | | | PLEASE SEE NOTICE WAS GIVEN ON PREVIOUS | | | REVIEW IN REFERENCE TO FS 553.80(2)(B) | | | WITH RESPECT TO DESIGN PROFESSIONAL. | | | A 4X FEE HAS NOW BEEN ACCESSED DUE TO | | | CODE COMPLIANCE COMMENTS BEING REPEATED | | | ON THE REVIEWS 3 OR MORE TIMES. | | | BZ 244396 $240.00 | | | THIS FEE IS REQUIRED TO BE PAID BEFORE | | | PLANS MAY BE RE-SUBMITTED. | | | ONE COPY OF EACH ELECTRICAL PLAN HAS NOW | | | BEEN RETAINED FOR FILE AND POSSIBLE | | | FURTHER ACTION TO BE TAKEN UP WITH | | | THE BOARD. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-22 |
Time |
14:12 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-06-22 |
Time |
14:12 |
Sent To |
P |
|
| Notes |
| 2004-06-22 00:00:00 | *********** UNSAT ***************** | | | | | | PLEASE SEE SOME NOTES AND REDLINED ITEMS | | | FROM FIRST REVIEW WERE NOT ADDRESSED. | | | PLANS ALSO HAVE CHANGES MADE FROM FIRST | | | SET OF PLANS THAT NOW HAVE COMMENTS. | | | | | | 1)NOTE: PLEASE SEE APPLICATION STILL | | | CALLS OUT FOR REMODEL OF BATH? | | | PLAN SHOWS COMPLETE REWIRE? | | | | | | 2)NOTE: PLEASE SEE 250.32 FOR GROUNDING | | | AT DETACHED BLDG. | | | | | | 3)NOTE: PLEASE SEE SOME CONDUITS ARE | | | \STILL MISSING EQUIPMENT GROUNDING | | | CONDUCTORS. 250.110,250.122 | | | PLEASE NOW SEE AN EQUIPMENT GRND HAS | | | BEEN ADDED TO RISE AHEAD OF METER AND | | | FROM METER TO THE FIRST MEANS OF DISC. | | | PLEASE SEE 250.24,250.6. THIS SHALL NOT | | | BE INSTALLED. | | | | | | 4)NOTE: PANEL AT MAIN HOUSE IS NOW BEING | | | SHOWN AS "MCO"?PLEASE ALSO SEE WHAT | | | APPEARS TO BE A MAIN DISC BEING ADDED | | | AHEAD OF 200A PANEL? | | | PLEASE SHOW ON PLANS AND CLARIFY IF | | | PANEL IS NOW A "MLO" W/ A MAIN DISC | | | OUTSIDE.? 215.5 | | | | | | 5)NOTE: PLEASE SEE SD'S STILL MISSING | | | AT DEATCHED BLDG. THIS IS CONSIDERED | | | AN ADAPTABLE SLEEPING AREA. SD'S ARE | | | REQUIRED INSIDE AND OUTSIDE ROOM. | | | | | | 6)NOTE: PLEASE SEE ORIG PLAN WAS RED- | | | -LINED FOR 210.52E FOR MISSING FRONT AND | | | REAR RECEPT(S). | | | | | | 7)NOTE:PLEASE SEE KW RATING FOR A/C UNIT | | | HAS NOW CHANGED TO 10KW. HOWEVER OCP | | | HAS NOW DROPPED BACK DOWN TO 40A'S? | | | PLEASE SEE 424.3B MIN 125%. | | | PLEASE ALSO SEE AWG HAS NOW CHANGED FROM | | | THE REQUIRED #6 AS SHOWN ON ORIG PLANS | | | TO #8?310.16 | | | | | | 8)NOTE: PLEASE SEE PANEL SCHEDULE NOW | | | HAS BEEN CHANGED TO SHOW SUB-FEEDERS AS | | | #8'S, YET RISER STILL IS SHOWING #6'S. | | | PLEASE CORRELATE. | | | | | | 9)NOTE: PLEASE SEE RISER DIAGRAM NOW | | | SHOWS OCP FOR A/C AHU. SHOWN AS 60A DISC | | | W/30A OCP>?? PLEASE SEE NOTE 7). | | | 424.3B. 10KW. CONDUCTORS ON RISER HAVE | | | NOW CHANGED ALSO. | | | | | | 10)NOTE: PLEASE SEE PLANS SHOW A 50A | | | DISC AT DETACHED BLDG AND RISER INDICATE | | | -S 60A? PLEASE CORRELATE. | | | | | | 11)NOTE: PLEASE SEE MISSING RECEPT IN | | | GARAGE PER 210.52G AND RECEPT FOR 2' | | | OF WALL IN MIDDLE BEDRM. 210.52 | | | NEW NOTE. | | | | | | 12)NOTE: PLEASE SEE COPY OF FS 553.80(2) | | | (B) ATTACHED. THIS IS A NOTICE GIVEN | | | WITH RESPECT TO DESIGN PROFESSIONAL. | | | THIS IS ONLY A NOTICEAT THIS TIME. | | | | | | PLEASE TAKE OUT AND REMOVE ALL OLD/ | | | VOIDED SHEETS. PLEASE ONLY INSERT NEW | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. ONE SET OF OLD SHEETS | | | MAY BE SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-17 |
Time |
15:16 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
13:15 |
Sent To |
P |
|
| Notes |
| 2004-05-04 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE APPLICATION WAS | | | SUBMITTED FOR REMODEL OF BATH YET PLANS | | | SHOW COMPLETE REMOD FOR ELECTRICAL ?? | | | PLEASE CLARIFY.??? | | | | | | 2)NOTE: PLEASE SEE FAC 61G1-16.004 FOR | | | ALL LICENSE #'S REQ'D ON TITLE BLOCK. | | | PLEASE ALSO SEE FS 481.219 FOR REQ'D | | | CERTIFICATE OF AUTHORIZATION #. | | | THIS IS FOR ALL TRADES AND ALL SHEETS | | | WEATHER OR NOT COMMENT IS MADE FROM | | | OTHER REVIEWERS. | | | | | | REVIEW FOR ELECTRICAL CODE COMPLIANCE | | | FOR NEW ELECTRICAL AS SHOWN. | | | | | | 1)NOTE: PLEASE SHOW ALL A/C EQUIPMENT | | | AND DISC'S PER 440.11, RECEPTS PER | | | 210.63/ 210.70 | | | | | | 2)NOTE: PLEASE SEE 220 FOR LOAD CALCU- | | | -LATIONS. PLEASE SEE 220.16, 220.18 | | | | | | 3)NOTE: PLEASE SEE NFPA-72 FOR REQ'D | | | SD'S MISSING. | | | | | | 4)NOTE: PLEASE SEE 210.8A6 FOR GFI | | | PROTECTION REQ'D. | | | | | | 5)NOTE: PLEASE SEE 424.3B FOR OCP | | | SHOWN FOR AHU. 60A FOR 5KW?? | | | | | | 6)NOTE: PLEASE SEE 225.31,250.32 FOR | | | DETACHED BLDG. | | | | | | 7)NOTE: PLEASE SEE 250.110, 250.122 FOR | | | MISSING EQUIPMENT GROUNDING CONDUCTORS | | | ON RISER DIAGRAM. | | | | | | 8)NOTE: PLEASE VERIFY COMPLIANCE W/ | | | 230.70 FOR MORE THAN 8' OF UNPROTECTED | | | CONDUCTORS INSIDE HOUSE FROM METER? | | | | | | 9)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 10)NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | 210.12, 2002 NEC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-27 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-27 |
Time |
09:50 |
Sent To |
E |
|
| Notes |
| 2004-10-27 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:28 |
Sent To |
E |
|
| Notes |
| 2004-10-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-30 |
Time |
09:22 |
Sent To |
E |
|
| Notes |
| 2004-08-30 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
11:49 |
Sent To |
E |
|
| Notes |
| 2004-08-16 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-29 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-17 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-17 |
Time |
15:15 |
Sent To |
E |
|
| Notes |
| 2004-06-17 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-28 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-28 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-19 |
Time |
13:09 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-08-19 |
Time |
13:09 |
Sent To |
B |
|
| Notes |
| 2004-08-19 00:00:00 | MECHANCIAL PLANS SUBMITTED WITH MECH | | | APPLICATION #04070786, SEPARATELY.NO | | | MECHANICAL WORK UNDER THIS PERMIT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-19 |
Time |
11:08 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-07-07 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2004-07-07 00:00:00 | DENIED: | | | PLANS ARE NOT IN COMPLIANCE WITH FS | | | 471.025 & FAC 61G15-23.002, PLANS ARE | | | TO BE SIGNED NOT INTITIALED BY THE | | | ENGINEER.ONE SET OF PLANS WILL BE | | | FORWARDED TO DBPR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-05-09 |
Time |
15:56 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-05-11 |
Time |
15:33 |
Sent To |
B |
|
| Notes |
| 2004-05-11 00:00:00 | NO MECHANICAL PLANS OR INFORMATION | | | SUBMITTED WITH PERMIT APPLICATION. | | | PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-03 |
Time |
14:27 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-03 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2004-11-03 00:00:00 | REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-28 |
Time |
13:59 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-22 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2004-10-23 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FAC 61G1-16.004 - FS481.2055 MISSING IN- | | | FORMATION ON TITLE BLOCK REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-06 |
Time |
20:06 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2004-09-18 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2004-09-18 00:00:00 | DENIED; | | | 1.FLOOR PLAN ON SHT. A-3 DOES NOT SHOW | | | WASHER AND L/T. PLUMBING FIXTURES ONLY | | | SHOWN ON SHEET A-4. SHOW HOW WASHER | | | AND L/T ARE TO BE PIPED ON RISER | | | DIAGRAM. | | | 2.RISER DIAGRAM FOR MAIN HOUSE. SHOW HOW | | | BATHROOM IS TIED INTO THE PLUMBING | | | SYSTEM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-01 |
Time |
15:57 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
M |
|
| Notes |
| 2004-05-09 00:00:00 | PROVISO: | | | SUBJECT TO FIELD INSPECTOR,PES |
|
|