Plan Review Details - Permit 04041914
Plan Review Stops For Permit 04041914
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-06-21 Cont ID  
Sent By lsmith Date 2004-06-21 Time 09:07 Rev Time 1.00
Received By lsmith Date 2004-06-21 Time 09:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-19 Cont ID  
Sent By jleech Date 2004-06-12 Time 13:08 Rev Time 2.50
Received By lsmith Date 2004-05-19 Time 13:50 Sent To  
Notes
2004-05-19 00:00:00SEE NOTES UNDER "I" STOP. PLAC ED THERE
 IN ERROR BY LEA SMITH

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-03-29 Cont ID  
Sent By dpalmer Date 2005-03-29 Time 13:58 Rev Time 0.50
Received By dpalmer Date 2005-03-29 Time 13:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-09 Cont ID  
Sent By dpalmer Date 2004-06-09 Time 10:59 Rev Time 0.33
Received By dpalmer Date 2004-06-09 Time 10:59 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-06-07 Time 14:17 Rev Time 0.33
Received By dpalmer Date 2004-05-10 Time 05:57 Sent To M
Notes
2004-05-10 00:00:00********* UNSAT ***************
  
 1)NOTE: PLEASE SEE MISSING LICENSE #'S
 REQUIRED TO BE PRINTED ON TITLE BLOCK.
 FS 481.219/ FAC 61G1-16.004
  
 2)NOTE: PLEASE SEE MISSING POOL PANEL
 FROM RISER DIAGRAM.
  
 3)NOTE: PLEASE SEE BOTH PANEL SCHEDULES
 AND RISER DIAGRAM SHOW PANELS AS MLO?
 PLEASE ADJUST TO INDICATE MCB IN BOTH
 LOCATIONS.
  
 4)NOTE: PLEASE SEE WHAT APPEARS TO BE
 A FLR RECEPT SHOWN IN THE PATH OF EGRESS
 TO OUTSIDE FROM LIVING RM?
 PLEASE ALSO SEE WHAT APPEARS TO BE BACK
 PORCH IS SHOWN AS LIVING RM?
  
 5)NOTE: PLEASE SEE 210.52C1 FOR MISSING
 RECEPT ON KIT COUNTER.
  
 6 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 7)NOTE: PLEASE SEE MISSING GFI RECEPT
 IN CABANA BATH. 210.52D
  
 8)NOTE: PLEASE SEE GFI SHOWN IN GARAGE
 APPEARS TO BE A DEDICATED RECEPT FOR
 GOLF CHARGER WHICH IS LISTED ON PANEL
 SCHEDULE.
 PLEASE SEE GFI REQ'D FOR GEN PURPOSE
 PER 210.52G/210.8
  
 9)NOTE: PLEASE SHOW SERVICE ON PLANS,
 PLEASE INDICATE LOCATION OF PANELS/METER
  
 PLEASE SEE ONE SET OF PLANS HAS BEEN
 HIGHLIGHTED FOR SOME OF THE ABOVE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-25 Cont ID  
Sent By adarroug Date 2005-03-25 Time 13:39 Rev Time 0.00
Received By adarroug Date 2005-03-25 Time 13:39 Sent To P
Notes
2005-03-25 00:00:00TO "KSTEVENS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-08 Cont ID  
Sent By adarroug Date 2005-03-08 Time 09:25 Rev Time 0.00
Received By adarroug Date 2005-03-08 Time 09:25 Sent To P
Notes
2005-03-08 00:00:00TO "KSTEVENS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-07 Cont ID  
Sent By csiegber Date 2004-06-07 Time 14:17 Rev Time 0.00
Received By csiegber Date 2004-06-07 Time 14:17 Sent To E
Notes
2004-06-07 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2004-05-19 Cont ID  
Sent By mmclean Date 2004-04-30 Time 17:15 Rev Time 2.50
Received By lsmith Date 2004-04-29 Time 08:40 Sent To  
Notes
2004-05-19 00:00:00BUIDING PLAN REVIEW FAILED:
  
 1.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 PRODUCT APPROVALS FOR THE FOLLOWING:
 WINDOWS
 DOORS
 GARAGE DOORS
 STRUCTUAL COMPONENTS
 STORM PANELS
 ROOF SYSTEM
  
 2. SQ. FOOTAGE HAS BEEN ADJUSTED PER
 PLANS. ADDITIONAL FEES OF $710.46 ARE
 DUE.
  
 3. A NOTICE OF COMMENCEMENT MUST BE
 FILED AND A COPY SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 4. PLANS MUST BE TAKEN TO PALM BEACH
 COUNTY AND COUNTY IMPACT FEES PAID.A
 COPY OF THE RECEIPT MUST BE SUBMITTED
 BEFORE A PERMIT CAN BE ISSUED.
  
 5. SUBMIT 2 COPIES OF THE FLORIDA
 ENERGYEFFICIENCY CODE WITH 1 EXTRA COPY
 OF THEFIRST PAGE.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713
2004-05-03 00:00:00TO SFD RACK/E
2004-04-29 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-06-11 Cont ID  
Sent By pkrauss Date 2004-06-11 Time \8:10 Rev Time 0.35
Received By pkrauss Date 2004-06-11 Time 07:51 Sent To P
Notes
2004-06-11 00:00:00PROVISO:
 THE ENERGY CACULAITONS SUBMITTED
 INDICATE BOTH SYSTEMS AS 12.60 SEER.
 THE EQUIPMENT SCHEDULE ON THE
 MECHANICAL PLAN INDICATES SYSTEM ONE AS
 12.60 SEER AND SYSTEM TWO AS 12.00
 SEER.PLEASE REVISE PLANS TO REFLECT
 THE ENERGY CALCULATIONS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-14 Cont ID  
Sent By dpalmer Date 2004-05-10 Time 05:57 Rev Time 0.30
Received By pkrauss Date 2004-05-14 Time 12:40 Sent To  
Notes
2004-05-14 00:00:00DENIED:
 NO MECHANICAL INFORMATION SUBMITTED FOR
 REVIEW.PLEASE PROVIDE ENERGY & MANUAL
 J CALCULATIONS PER 2001 FBC CHAPTER 13
 SUB-CHAPTER 6.PLEASE PROVIDE PLANS
 WITH DUCT AND GRILLE SIZE, MATERIAL AND
 LAYOUT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-06-12 Cont ID  
Sent By jleech Date 2004-06-12 Time 13:07 Rev Time 0.33
Received By jleech Date 2004-06-12 Time 13:07 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-19 Cont ID  
Sent By pkrauss Date 2004-06-11 Time 08:10 Rev Time 0.50
Received By kstevens Date 2004-05-19 Time 07:11 Sent To B
Notes
2004-05-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT A6 THE SANITARY RISER DIAGRAM
 DOES NOT REFLECT THE FLOOR PLAN, NOR
 DOES IT MEET CODE REQUIREMENTS.
 A) THE RISER IS REVERSE FROM THE FLOOR
 PLAN. SUBMIT A RISER THAT REFLECTS THE
 FLOOR PLAN. SECTION 104.2.1.
 B) PROPERLY IDENTIFY ALL FIXTURES ON
 THE RISER DIAGRAM. SECTION 104.2.1.
 C) SIZE ALL PIPES IN SYSTEM. TABLES
 709.1, 710.1(1) & 710.1(2) AND SECTION
 104.2.1.
 D) CLEAN OUT REQUIRED 4' ABOVE THE
 FLOOR AT WASH MACHINE. SECTION 708.10.
 E) STAND PIPE REQUIRED AT THE WASH
 MACHINE. SECTIONS 802.4 & 1002.1.
 F) THE WASH MACHINE SHALL CONNECT DOWN-
 STREAM OF THE LAUNDRY SINK ON THE STACK.
 SECTION 706.3.
 G) THE LAUNDRY SINK AND WASH MACHINE
 SHALL DISCHARGE DOWNSTREAM OF THE WET-
 VENTED HORIZONTAL DRAIN FOR BATH #2.
 SECTION 909.1.
 H) THE WATER CLOSET AND SHOWER ARE NOT
 VENTED PROPERLY IN BATH #2. SECTIONS
 901.2.1 & 909.1.
 I) THE BIDET IS NOT VENTED IN THE MAST-
 ER BATH. SECTION 901.2.1.
 J) THE CABANA BATH SHOWS A SHOWER ON
 THE RISER DIAGRAM THAT IS NOT SHOWN ON
 THE FLOOR PLAN, AND THE RISER SHOWS THE
 CABANA BATH ON THE WRONG SIDE OF THE
 HOUSE. SECTION 104.2.1.
 2) THE SANITARY RISER DIAGRAM SHALL RE-
 FLECT THE INSTALLATION OF THE PIPE AND
 I SUGGEST THAT THE PLUMBING CONTRACTOR
 BE CONTACTED SO HE CAN INDICATE HOW THE
 PIPING WILL BE INSTALLED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-30 Cont ID  
Sent By mmclean Date 2004-04-30 Time 17:15 Rev Time 0.00
Received By mmclean Date 2004-04-30 Time 17:15 Sent To I
Notes
***NONE***