| Plan Review Stops For Permit 04041914 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-06-21 |
Time |
09:07 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-06-21 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-12 |
Time |
13:08 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2004-05-19 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | SEE NOTES UNDER "I" STOP. PLAC ED THERE | | | IN ERROR BY LEA SMITH |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-29 |
Time |
13:58 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-29 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-09 |
Time |
10:59 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-09 |
Time |
10:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
14:17 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-10 |
Time |
05:57 |
Sent To |
M |
|
| Notes |
| 2004-05-10 00:00:00 | ********* UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE MISSING LICENSE #'S | | | REQUIRED TO BE PRINTED ON TITLE BLOCK. | | | FS 481.219/ FAC 61G1-16.004 | | | | | | 2)NOTE: PLEASE SEE MISSING POOL PANEL | | | FROM RISER DIAGRAM. | | | | | | 3)NOTE: PLEASE SEE BOTH PANEL SCHEDULES | | | AND RISER DIAGRAM SHOW PANELS AS MLO? | | | PLEASE ADJUST TO INDICATE MCB IN BOTH | | | LOCATIONS. | | | | | | 4)NOTE: PLEASE SEE WHAT APPEARS TO BE | | | A FLR RECEPT SHOWN IN THE PATH OF EGRESS | | | TO OUTSIDE FROM LIVING RM? | | | PLEASE ALSO SEE WHAT APPEARS TO BE BACK | | | PORCH IS SHOWN AS LIVING RM? | | | | | | 5)NOTE: PLEASE SEE 210.52C1 FOR MISSING | | | RECEPT ON KIT COUNTER. | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 7)NOTE: PLEASE SEE MISSING GFI RECEPT | | | IN CABANA BATH. 210.52D | | | | | | 8)NOTE: PLEASE SEE GFI SHOWN IN GARAGE | | | APPEARS TO BE A DEDICATED RECEPT FOR | | | GOLF CHARGER WHICH IS LISTED ON PANEL | | | SCHEDULE. | | | PLEASE SEE GFI REQ'D FOR GEN PURPOSE | | | PER 210.52G/210.8 | | | | | | 9)NOTE: PLEASE SHOW SERVICE ON PLANS, | | | PLEASE INDICATE LOCATION OF PANELS/METER | | | | | | PLEASE SEE ONE SET OF PLANS HAS BEEN | | | HIGHLIGHTED FOR SOME OF THE ABOVE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-25 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-25 |
Time |
13:39 |
Sent To |
P |
|
| Notes |
| 2005-03-25 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-08 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-08 |
Time |
09:25 |
Sent To |
P |
|
| Notes |
| 2005-03-08 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
14:17 |
Sent To |
E |
|
| Notes |
| 2004-06-07 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
17:15 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2004-04-29 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | BUIDING PLAN REVIEW FAILED: | | | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | WINDOWS | | | DOORS | | | GARAGE DOORS | | | STRUCTUAL COMPONENTS | | | STORM PANELS | | | ROOF SYSTEM | | | | | | 2. SQ. FOOTAGE HAS BEEN ADJUSTED PER | | | PLANS. ADDITIONAL FEES OF $710.46 ARE | | | DUE. | | | | | | 3. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AND A COPY SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4. PLANS MUST BE TAKEN TO PALM BEACH | | | COUNTY AND COUNTY IMPACT FEES PAID.A | | | COPY OF THE RECEIPT MUST BE SUBMITTED | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 5. SUBMIT 2 COPIES OF THE FLORIDA | | | ENERGYEFFICIENCY CODE WITH 1 EXTRA COPY | | | OF THEFIRST PAGE. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | 2004-05-03 00:00:00 | TO SFD RACK/E | | 2004-04-29 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-11 |
Time |
\8:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-11 |
Time |
07:51 |
Sent To |
P |
|
| Notes |
| 2004-06-11 00:00:00 | PROVISO: | | | THE ENERGY CACULAITONS SUBMITTED | | | INDICATE BOTH SYSTEMS AS 12.60 SEER. | | | THE EQUIPMENT SCHEDULE ON THE | | | MECHANICAL PLAN INDICATES SYSTEM ONE AS | | | 12.60 SEER AND SYSTEM TWO AS 12.00 | | | SEER.PLEASE REVISE PLANS TO REFLECT | | | THE ENERGY CALCULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-10 |
Time |
05:57 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-05-14 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | DENIED: | | | NO MECHANICAL INFORMATION SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE ENERGY & MANUAL | | | J CALCULATIONS PER 2001 FBC CHAPTER 13 | | | SUB-CHAPTER 6.PLEASE PROVIDE PLANS | | | WITH DUCT AND GRILLE SIZE, MATERIAL AND | | | LAYOUT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-12 |
Time |
13:07 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-06-12 |
Time |
13:07 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-11 |
Time |
08:10 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-19 |
Time |
07:11 |
Sent To |
B |
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A6 THE SANITARY RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN, NOR | | | DOES IT MEET CODE REQUIREMENTS. | | | A) THE RISER IS REVERSE FROM THE FLOOR | | | PLAN. SUBMIT A RISER THAT REFLECTS THE | | | FLOOR PLAN. SECTION 104.2.1. | | | B) PROPERLY IDENTIFY ALL FIXTURES ON | | | THE RISER DIAGRAM. SECTION 104.2.1. | | | C) SIZE ALL PIPES IN SYSTEM. TABLES | | | 709.1, 710.1(1) & 710.1(2) AND SECTION | | | 104.2.1. | | | D) CLEAN OUT REQUIRED 4' ABOVE THE | | | FLOOR AT WASH MACHINE. SECTION 708.10. | | | E) STAND PIPE REQUIRED AT THE WASH | | | MACHINE. SECTIONS 802.4 & 1002.1. | | | F) THE WASH MACHINE SHALL CONNECT DOWN- | | | STREAM OF THE LAUNDRY SINK ON THE STACK. | | | SECTION 706.3. | | | G) THE LAUNDRY SINK AND WASH MACHINE | | | SHALL DISCHARGE DOWNSTREAM OF THE WET- | | | VENTED HORIZONTAL DRAIN FOR BATH #2. | | | SECTION 909.1. | | | H) THE WATER CLOSET AND SHOWER ARE NOT | | | VENTED PROPERLY IN BATH #2. SECTIONS | | | 901.2.1 & 909.1. | | | I) THE BIDET IS NOT VENTED IN THE MAST- | | | ER BATH. SECTION 901.2.1. | | | J) THE CABANA BATH SHOWS A SHOWER ON | | | THE RISER DIAGRAM THAT IS NOT SHOWN ON | | | THE FLOOR PLAN, AND THE RISER SHOWS THE | | | CABANA BATH ON THE WRONG SIDE OF THE | | | HOUSE. SECTION 104.2.1. | | | 2) THE SANITARY RISER DIAGRAM SHALL RE- | | | FLECT THE INSTALLATION OF THE PIPE AND | | | I SUGGEST THAT THE PLUMBING CONTRACTOR | | | BE CONTACTED SO HE CAN INDICATE HOW THE | | | PIPING WILL BE INSTALLED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-30 |
Time |
17:15 |
Sent To |
I |
|
| Notes |
|
|