| Plan Review Stops For Permit 04041812 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-28 |
Time |
09:30 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2004-06-28 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-11 |
Time |
13:37 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2004-05-17 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | DENIED | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2."R" VALUE FOR WALL INSULATION ON | | | ENERGY CALCS DOES NOT MATCH PLANS. | | | | | | 3.ROYAL WALL:SUBMIT A LETTER FROM A | | | LICENSED THRESHOLD INSPECTOR STATING | | | THAT ANINSPECTION WILL BE MADE AT THE | | | MAMUFATURED SITE OF THE JOB SPECIFIC | | | COMPONENTS TO VERIFY CONSTRUCTION | | | COMPLIANCE OF THE COMPONENTS WITH THE | | | ENGINEERED DESIGN. | | | | | | 4.VERIFY THAT ALL USP AND SIMPSON | | | CONNECTORS ARE INSTALLED ACCORDING TO | | | MANUFACURERS SPECS. REVISE ON PAGE RF-1. | | | | | | 5. ACCORDING TO SBCCI BUILDING VALUATION | | | DATA THE VALUATION HAS BEEN CHANGED TO | | | $262,163. THE CURRENT SF PRICE IS $76.96 | | | | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-23 |
Time |
20:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-23 |
Time |
20:25 |
Sent To |
M |
|
| Notes |
| 2004-06-23 00:00:00 | ************ PROVISO/ REVISION ****** | | | | | | 1 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE REVISE PLANS TO SHOW ACTUAL | | | INSTALLATION. PLANS SHOW "OPTS" FOR | | | MANY RECESSED LTS. | | | | | | PLEASE SUBMIT REVISED PLANS BEFORE | | | ROUGH ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
10:46 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-07 |
Time |
07:24 |
Sent To |
M |
|
| Notes |
| 2004-05-07 00:00:00 | **** UNSAT ** | | | | | | 1)NOTE: PLEASE HAVE ARCH SIGN PLANS WITH | | | SIGNATURE AS REQ'D UNDER FS 481.221/ | | | MUST CONTAIN A MIN OF FIRST AND LAST | | | ANME. CONVERSATION W/ STATE DBPR, | | | INITIALS ARE NOT PERMITTED. | | | PLEASE ALSO BE SURE RAISED SEAL IS | | | CLEAR AND VISABLE. | | | | | | 2)NOTE : APLER SEE MISSSING SD IN WHAT | | | APPEARS TO BE A BEDROOM. RM DESIGNATIONS | | | ARE NOT ON PLANS TO VERIFY THIS. | | | PLEASE SEE ONE COPY OF PLANS ARE NOTED | | | | | | PLEASE SUBMIT THE ABOVE INFORMATIONFOR | | | REVIEW, IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-23 |
Time |
10:46 |
Sent To |
E |
|
| Notes |
| 2004-06-23 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-28 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-27 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | TO SFD RACK/E | | 2004-04-27 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-25 |
Time |
14:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-25 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-23 |
Time |
20:25 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-05-11 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
| 2004-05-11 00:00:00 | DENIED: | | | RETURN AIR FROM BEDROOM AREAS ARE NOT | | | SIZED PROPERLY.PER THE REVISED 2001 | | | FBC(M) 601.4 EFFECTIVE JUNE 30, 2003, | | | THE RETURN AIR SHALL BE SIZED AS | | | FOLLOWS: | | | | | | BEDROOM SUITE #2 RETURN AIR JUMPER = 12" | | | BEDROOM SUITE #3 RETURN AIR JUMPER = 12" | | | MASTER SUITE = 14 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-05-08 |
Time |
11:05 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-05-08 |
Time |
11:05 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-28 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-28 |
Time |
17:57 |
Sent To |
I |
|
| Notes |
|
|