| Plan Review Stops For Permit 04041627 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-29 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-29 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2006-03-29 00:00:00 | THIS PERMIT IS BEING ISSUED AS THE LAST | | | PERMIT FOR THE PROJECT AS AGREED TO WITH | | | THE CONTRACTOR PRIOR TO ISSUANCE OF | | | MASTER PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2005-05-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-05 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-05 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2005-05-05 00:00:00 | REVISIONS TO SHEETS A6,A11 AND A12 ARE | | | OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-01 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-01 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | REVISIONS TO SHEETS A6 AND A12 ARE OK. | | | ALL BUILDINGS CONSTRUCTED UNDER THIS | | | MASTER ARE TO REFLECT THESE REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-20 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-20 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | REVISIONS TO MASTER SHEETS | | | A1,A7,A8,A9,A10,A11 ARE OK. THIS IS | | | BEING ALLOWED BY B. STAPLES AFTER | | | DISCUSSIONS WITH TOM MOORE (FIELD | | | INSPECTOR) CONFIRMING THAT REVISIONS ARE | | | CONSISTENT FOR ALL STRUCTURES UNDER | | | CONSTRUCTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-17 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | SHOP DRAWINGS FOR THE FILIGREE FLOOR | | | SYSTEM ARE OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-09 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-09 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | DENIED | | | | | | 1) THE LIVE LOAD FOR BALCONIES CAN BE NO | | | LESS 60 PSF PER FBC TABLE 1604.1. | | | | | | 2) REDLINED CHANGES TO SIGNED AND SEALED | | | PLANS ARE REQUIRED TO BE INITIALED AND | | | DATED BY THE DESIGNER OF RECORD FOR THE | | | DOCUMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-08-25 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-25 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-12 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | DENIED | | | | | | 1) ON SHEET A-9 LOWER ROOF PLAN, TRUSS | | | AT4 ON THE LEFT SIDE OF THE PLAN HAS ITS | | | UPLIFT AND CONNECTOR SPECIFIED AT THE | | | ADJACENT TRUSS, WHICH HAS A MUCH LOWER | | | UPLIFT. | | | | | | 2) THE UPLIFT FOR ONE END OF TRUSS AT16 | | | IN THE TRUSS DRAWINGS EXCEEDS THE | | | CAPACITY OF THE ANCHOR SPECIFIED ON | | | SHEET 9 OF THE PLANS. | | | | | | 3) TRUSSES AT19 AND AT20 ON A-9 EXCEED | | | THE CONNECTOR CAPACITY. | | | | | | 4) ON SHEET A-10 TRUSS BT48 EXCEEDS THE | | | UPLIFT CAPACITY OF THE SPECIFIED | | | CONNECTOR. | | | | | | 5) ON SHEET A-10 TRUSS BT42 HAS AN | | | UPLIFT ON TRUSS DRAWINGS THAT EXCEEDS | | | THE ONE GIVEN ON THE PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-26 |
Time |
11:44 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-07-26 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | DENIED | | | | | | 1) NO TRUSS DRAWINGS WERE SUBMITTED. | | | | | | 2) THE WRONG PRODUCT APPROVAL WAS | | | SUBMITTED FOR THE ENTRY DOORS. THE ONE | | | SUBMITTED HAS A NON IMPACT RATED GLAZED | | | STEEL DOOR WITH SIDELITES. THE DOOR AND | | | SIDELITES MUST BE SHUTTERED. | | | | | | 3) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 4) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-07 |
Time |
13:19 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-07-07 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2004-07-07 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) THE 48"X 56" CLEAR FLOOR SPACE AT THE | | | TOILET IS NOT SHOWN IN THE PROPER | | | ORIENTATION. SEE FAIR HOUSING DESIGN | | | MANUAL PAGE 7.43. | | | | | | 4)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 5) SUBMIT A KEY PLAN AND AN INSTALLATION | | | SCHEDULE FOR EACH ONE OF THE 4 UNITS. | | | | | | 6) THE LETTER FROM PALM BEACH LIFTS HAS | | | THE WRONG PERMIT NUMBER. PLEASE CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-05-21 |
Time |
15:13 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
2004-05-21 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) REVISE PLAN NOTE 10 ON C1. IMPACT | | | PROTECTION IS REQUIRED IN WIND BORNE | | | DEBRIS REGIONS PER FBC 1606.1.4. | | | | | | 4) SPECIFY THAT THE DOORS FROM THE | | | GARAGE TO THE HABITABLE SPACE ARE | | | REQUIRED TO BE 3/4 HOUR FIRE RATED DOORS | | | WITH CLOSERS. SEE FBC 705.1.3. | | | | | | 5) THE WALLS BETWEEN THE GARAGES AND THE | | | HABITABLE SPACE ARE REQUIRED TO BE ONE | | | HOUR FIRE RATED PER FBC 411.2.6 AND 704. | | | | | | 6) THE WALLS BETWEEN THE GARAGES AND | | | CONDITIONED SPACE ARE REQUIRED TO BE | | | INSULATED PER FBC CHAPTER 13. | | | | | | 7) SHOW COMPLIANCE WITH FAIR HOUSING ACT | | | DESIGN MANUAL. SHOW MINIMUM CLEAR FLOOR | | | SPACE AT TOILET OF 48"X56". CENTER OF | | | TOILET TO BE 18" OFF WALL. SEE FHADM | | | PAGE 7.43. | | | | | | 8) ALL DOORS THAT A PERSON MUST PASS | | | THROUGH (SUCH AS WALK IN CLOSETS, BATHS, | | | ETC.) MUST MEET THE REQUIREMENTS FOR | | | "USEABLE" DOORS AND PROVIDE A 32"NOMINAL | | | CLEAR OPENING. A 2'-10" DOOR IS REQUIRED | | | SEE FHADM PG. 3.5. | | | | | | 9) THE GROUND FLOOR AND SECOND FLOOR | | | GROSS AREA CALCS. ARE INCORRECT. PLEASE | | | CORRECT. | | | | | | 10) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 11) SPECIFY THE TRUSS BOTTOM CORD LIVE | | | LOAD ON THE PLANS. SEE FBC TABLE 1604.1. | | | | | | 12) SUBMIT KEY PLANS AND INSTALLATION | | | SCHEDULES FOR THE STORM PANELS. | | | | | | 13) THE MISSLE IMPACT PROTECTION | | | INSTALLATION PLAN NEEDS TO BE SIGNED AND | | | NOTARIZED. IT MUST ALSO BE APPROVED BY | | | THE BUILDING OFFICIAL. | | | | | | 14) SUBMIT ENGINEERING FOR THE BALCONY | | | GUARD RAILS. | | | | | | 15) SUBMIT COMPLIANCE LETTER FROM PALM | | | BEACH LIFTS. | | | | | | 16) PLEASE SUBMIT TWO COPIES OF ALL | | | ITEMS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-14 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-14 |
Time |
09:14 |
Sent To |
PC |
|
| Notes |
| 2006-09-14 00:00:00 | PLANS HAD TO BE TAKEN ABCK TO ARCHITECT | | | ONCE AGAIN TO BE SEALED. | | | THE PLANS WERE TURNED AROUND WHEN THEY | | | CAME BACK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-11 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-11 |
Time |
18:22 |
Sent To |
P |
|
| Notes |
| 2006-09-11 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE THAT THE RAISED SEAL | | | MUST BE CLEAR AND VISABLE WITH ALL | | | INFORMATION AS REQUIRED ON SAID SEAL. | | | FAC 61G16-1.003 FS 481.221 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-02 |
Time |
13:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2004-08-02 00:00:00 | STAMPED NEW ELEC SHEETS. | | | REDLINED MISSING EQUIPMENT GRNDS 250.122 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
19:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
19:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-08-02 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-08-02 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-05-06 |
Time |
09:10 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-05-06 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-22 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-22 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2004-06-22 00:00:00 | 1) BUILDING ADDRESSES ARE REQUIRED ON | | | PROPER LOCATIONS SO POLICE, FIRE AND | | | PARAMEDICS CAN FIND THE EMERGENCY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-05 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-05 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED | | | PRIOR TO, DURING AND AFTER | | | CONSTRUCTION. | | | | | | 2) SMOKE DETECTORS MISSING FROM | | | BEDROOMS # 2. SECOND FLOOR ELECTRICAL | | | PLAN. | | | | | | 3) EGRESS WINDOWS REQUIRED FOR | | | SLEEPING ROOMS. | | | | | | 4) PORTABLE FIRE EXTINGUISHERS | | | REQUIRED. | | | | | | 5) BUILDING ADDRESSES REQUIRED. | | | | | | 6) ELECTRIC POWERED SMOKE DETECTORS | | | ARE REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-13 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-13 |
Time |
10:47 |
Sent To |
E |
|
| Notes |
| 2006-09-13 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
15:07 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-12 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-12 |
Time |
11:27 |
Sent To |
B |
|
| Notes |
| 2005-04-12 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-17 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-17 |
Time |
16:57 |
Sent To |
M |
|
| Notes |
| 2005-02-17 00:00:00 | TO HMOSER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2005-02-14 00:00:00 | TO RMCDOUGAL DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
14:33 |
Sent To |
B |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "ROB MCD" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
16:47 |
Sent To |
B |
|
| Notes |
| 2004-11-12 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-09 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-09 |
Time |
11:36 |
Sent To |
B |
|
| Notes |
| 2004-11-09 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-19 |
Time |
16:54 |
Sent To |
B |
|
| Notes |
| 2004-08-19 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-21 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | TO COMM BD#62 | | 2004-07-21 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-17 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-16 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | TO COMM BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-29 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-04-26 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | TO COMM BD#63 | | 2004-04-26 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-03 |
Time |
13:03 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-03-03 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2005-03-03 00:00:00 | PROVISO: | | | DRYER EXHAUST SHALL COMPLY WITH 2001 | | | FBC(M)504.6 AND TERMINATE IN SUCH A | | | MANNER NOT TO BE RECIRCULATED INTO FRESH | | | AIR INTAKES OR CREATE A NUISANCE.2001 | | | FBC(M)401.5.2 AND 501.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-09 |
Time |
10:41 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-07-09 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2004-07-09 00:00:00 | APPROVED/PLANS STAMPED 6-24-04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-07 |
Time |
07:10 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-05-07 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2004-05-07 00:00:00 | DENIED: | | | 1.ONLY ONE SET OF MECHANICAL PLANS | | | SUBMITTED FOR REVIEW.PER 2001 FBC(M) | | | 104.2.1, PROVIDE TWO OR MORE COPIES OF | | | PLANS AND SPECIFICATIONS. | | | | | | 2.PLANS INDICATE O.A. CALCULATIONS | | | PER 2001 FBC(M) 402.2, PROVIDE | | | CALCULATIONS ON PLAN. | | | | | | 3.1ST FLOOR "SANTA BARBARA", SOME OF | | | THE DUCTS ARE NOT SIZED.INDICATE IF | | | THEY ARE "TYPICAL". | | | | | | 4."SANTA BARBARA" DOES NOT INDICATE | | | RETURN AIR TO ROOMS SEPARATED BY DOORS. | | | SHOW COMPLIANCE WITH REVISED 2001 | | | FBC(M) 601.4.PLEASE NOTE, ALL RETURN | | | AIR INTO THE MASTER SUITE IS TO BE | | | INCLUDED IN THE CALCULATION FOR A | | | "TOTAL" OF SUPPLY AIR TO THAT SPACE. | | | | | | 5.AC NOTES INDICATE AUXILIARY DRAIN | | | PAN WITH FLOAT SWITCH FOR THE 2ND FLOOR | | | UNITS ONLY.THIS IS INCORRECT, PER | | | 2001 FBC(M) 307.2.3, ALL COILS ARE TO | | | HAVE PROTECTION. | | | | | | 6.1ST FLOOR DRYER EXHAUST INDICATES | | | VENT TO ROOF.PLANS DO NOT INDICATE | | | WHAT TYPE OF DUCT WILL BE USED FOR THE | | | DRYER EXHAUST.PROVIDE UL LISTING AND | | | DETAIL FOR THE PENETRATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-08-25 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-25 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-31 |
Time |
12:19 |
Rev Time |
1.23 |
| Received By |
kstevens |
Date |
2004-07-31 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2004-07-31 00:00:00 | PASSED/PROVISO | | | | | | TABLE 909.3 MAX 4 DFU'S ON 2" WET VENT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
09:34 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2004-07-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-98 DESIGN MANUAL | | | | | | A) COMMENTS FROM THE PREVIOUS REVIEW | | | WERE NOT ADDRESSED, OR NOT ADDRESSED | | | PROPERLY. | | | 1) SHT A-8 SHOW BACKING FOR GRAB BARS AT | | | WATER CLOSETS. SEE PAGES 6.4 & 6.5 OF | | | THE DESIGN MANUAL. COMMENT RESPONSE | | | NOTED, BUT WAS NOT SUFFICIENT. | | | 2) SHT A-12 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | D) MAXIMUM DFU ON 2" WET VENT IS 4 PER | | | TABLE 909.3. MASTER BATH SHOWS 6 DFU'S | | | ON 2" PIPE. NO RESPONSE NOTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-14 |
Time |
13:49 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2004-05-14 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FHA-98 AMEND. DESIGN MANUAL | | | | | | 1) SHT A-8 SHOW BACKING FOR GRAB BARS AT | | | WATER CLOSETS. SEE PAGES 6.4 & 6.5 OF | | | THE DESIGN MANUAL. | | | 2) SHT A-12 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS: | | | A) BOTH BATH #2 SHOWER IS SHOWN TO THE | | | RIGHT OF THE WATER CLOSET AND LAV TO THE | | | LEFT ON THE FLOOR PLAN. SECTION 104.2.1 | | | B) LAUNDRY TRAY AND WASH MACHINE SHALL | | | DISCHARGE DOWNSTREAM OF THE WET VEN FOR | | | THE POWDER ROOM PER SECTION 909.1 | | | C) PER TABLE 906.1 THE MAXIMUM DISTANCE | | | FROM THE TRAP TO THE VENT IS 6'. THE | | | WASH MACHINE APPEARS TO BE LONGER. THE | | | FLOOR LAYOUT INDICATES THAT SEPARATE | | | STACKS SHOULD WORK. | | | D) MAXIMUM DFU ON 2" WET VENT IS 4 PER | | | TABLE 909.3. MASTER BATH SHOWS 6 DFU'S | | | ON 2" IN BOTH MASTER BATHS. | | | E) LAVS ARE ON SEPARATE WALLS IN MASTER | | | BATHS AND REQUIRE SEPARATE STACKS FOR | | | EACH. MAXIMUM 5' FROM TRAP TO VENT PER | | | TABLE 906.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-10 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-10 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2004-08-10 00:00:00 | NO ZONING REQUIRED FOR RESUB MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-29 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-29 |
Time |
13:20 |
Sent To |
I |
|
| Notes |
| 2004-04-29 00:00:00 | OK PER GRACE JOYCE MM |
|
|