Plan Review Details - Permit 04041627
Plan Review Stops For Permit 04041627
Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2006-03-29 Cont ID  
Sent By rmcdouga Date 2006-03-29 Time 14:27 Rev Time 0.00
Received By rmcdouga Date 2006-03-29 Time 14:27 Sent To  
Notes
2006-03-29 00:00:00THIS PERMIT IS BEING ISSUED AS THE LAST
 PERMIT FOR THE PROJECT AS AGREED TO WITH
 THE CONTRACTOR PRIOR TO ISSUANCE OF
 MASTER PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2005-05-05 Cont ID  
Sent By rmcdouga Date 2005-05-05 Time 08:04 Rev Time 0.00
Received By rmcdouga Date 2005-05-05 Time 08:04 Sent To  
Notes
2005-05-05 00:00:00REVISIONS TO SHEETS A6,A11 AND A12 ARE
 OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2005-03-01 Cont ID  
Sent By rmcdouga Date 2005-03-01 Time 14:33 Rev Time 0.00
Received By rmcdouga Date 2005-03-01 Time 14:33 Sent To  
Notes
2005-03-01 00:00:00REVISIONS TO SHEETS A6 AND A12 ARE OK.
 ALL BUILDINGS CONSTRUCTED UNDER THIS
 MASTER ARE TO REFLECT THESE REVISIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-12-20 Cont ID  
Sent By rmcdouga Date 2004-12-20 Time 08:51 Rev Time 0.00
Received By rmcdouga Date 2004-12-20 Time 07:18 Sent To  
Notes
2004-12-20 00:00:00REVISIONS TO MASTER SHEETS
 A1,A7,A8,A9,A10,A11 ARE OK. THIS IS
 BEING ALLOWED BY B. STAPLES AFTER
 DISCUSSIONS WITH TOM MOORE (FIELD
 INSPECTOR) CONFIRMING THAT REVISIONS ARE
 CONSISTENT FOR ALL STRUCTURES UNDER
 CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status N Date 2004-11-17 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 14:34 Rev Time 0.00
Received By rmcdouga Date 2004-11-17 Time 07:04 Sent To  
Notes
2004-11-17 00:00:00SHOP DRAWINGS FOR THE FILIGREE FLOOR
 SYSTEM ARE OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status N Date 2004-11-09 Cont ID  
Sent By rmcdouga Date 2004-11-09 Time 15:31 Rev Time 0.00
Received By rmcdouga Date 2004-11-09 Time 15:31 Sent To  
Notes
2004-11-09 00:00:00DENIED
  
 1) THE LIVE LOAD FOR BALCONIES CAN BE NO
 LESS 60 PSF PER FBC TABLE 1604.1.
  
 2) REDLINED CHANGES TO SIGNED AND SEALED
 PLANS ARE REQUIRED TO BE INITIALED AND
 DATED BY THE DESIGNER OF RECORD FOR THE
 DOCUMENT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-08-25 Cont ID  
Sent By rmcdouga Date 2004-08-25 Time 10:04 Rev Time 0.00
Received By rmcdouga Date 2004-08-25 Time 10:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-08-12 Cont ID  
Sent By csiegber Date 2004-08-19 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2004-08-12 Time 13:58 Sent To  
Notes
2004-08-12 00:00:00DENIED
  
 1) ON SHEET A-9 LOWER ROOF PLAN, TRUSS
 AT4 ON THE LEFT SIDE OF THE PLAN HAS ITS
 UPLIFT AND CONNECTOR SPECIFIED AT THE
 ADJACENT TRUSS, WHICH HAS A MUCH LOWER
 UPLIFT.
  
 2) THE UPLIFT FOR ONE END OF TRUSS AT16
 IN THE TRUSS DRAWINGS EXCEEDS THE
 CAPACITY OF THE ANCHOR SPECIFIED ON
 SHEET 9 OF THE PLANS.
  
 3) TRUSSES AT19 AND AT20 ON A-9 EXCEED
 THE CONNECTOR CAPACITY.
  
 4) ON SHEET A-10 TRUSS BT48 EXCEEDS THE
 UPLIFT CAPACITY OF THE SPECIFIED
 CONNECTOR.
  
 5) ON SHEET A-10 TRUSS BT42 HAS AN
 UPLIFT ON TRUSS DRAWINGS THAT EXCEEDS
 THE ONE GIVEN ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-07-27 Cont ID  
Sent By rmcdouga Date 2004-07-26 Time 11:44 Rev Time 3.00
Received By rmcdouga Date 2004-07-26 Time 11:42 Sent To  
Notes
2004-07-26 00:00:00DENIED
  
 1) NO TRUSS DRAWINGS WERE SUBMITTED.
  
 2) THE WRONG PRODUCT APPROVAL WAS
 SUBMITTED FOR THE ENTRY DOORS. THE ONE
 SUBMITTED HAS A NON IMPACT RATED GLAZED
 STEEL DOOR WITH SIDELITES. THE DOOR AND
 SIDELITES MUST BE SHUTTERED.
  
 3) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 4) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-07-07 Cont ID  
Sent By rmcdouga Date 2004-07-07 Time 13:19 Rev Time 3.00
Received By rmcdouga Date 2004-07-07 Time 13:19 Sent To  
Notes
2004-07-07 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE 48"X 56" CLEAR FLOOR SPACE AT THE
 TOILET IS NOT SHOWN IN THE PROPER
 ORIENTATION. SEE FAIR HOUSING DESIGN
 MANUAL PAGE 7.43.
  
 4)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 5) SUBMIT A KEY PLAN AND AN INSTALLATION
 SCHEDULE FOR EACH ONE OF THE 4 UNITS.
  
 6) THE LETTER FROM PALM BEACH LIFTS HAS
 THE WRONG PERMIT NUMBER. PLEASE CORRECT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-21 Cont ID  
Sent By rmcdouga Date 2004-05-21 Time 15:13 Rev Time 4.00
Received By rmcdouga Date 2004-05-21 Time 15:13 Sent To  
Notes
2004-05-21 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) REVISE PLAN NOTE 10 ON C1. IMPACT
 PROTECTION IS REQUIRED IN WIND BORNE
 DEBRIS REGIONS PER FBC 1606.1.4.
  
 4) SPECIFY THAT THE DOORS FROM THE
 GARAGE TO THE HABITABLE SPACE ARE
 REQUIRED TO BE 3/4 HOUR FIRE RATED DOORS
 WITH CLOSERS. SEE FBC 705.1.3.
  
 5) THE WALLS BETWEEN THE GARAGES AND THE
 HABITABLE SPACE ARE REQUIRED TO BE ONE
 HOUR FIRE RATED PER FBC 411.2.6 AND 704.
  
 6) THE WALLS BETWEEN THE GARAGES AND
 CONDITIONED SPACE ARE REQUIRED TO BE
 INSULATED PER FBC CHAPTER 13.
  
 7) SHOW COMPLIANCE WITH FAIR HOUSING ACT
 DESIGN MANUAL. SHOW MINIMUM CLEAR FLOOR
 SPACE AT TOILET OF 48"X56". CENTER OF
 TOILET TO BE 18" OFF WALL. SEE FHADM
 PAGE 7.43.
  
 8) ALL DOORS THAT A PERSON MUST PASS
 THROUGH (SUCH AS WALK IN CLOSETS, BATHS,
 ETC.) MUST MEET THE REQUIREMENTS FOR
 "USEABLE" DOORS AND PROVIDE A 32"NOMINAL
 CLEAR OPENING. A 2'-10" DOOR IS REQUIRED
 SEE FHADM PG. 3.5.
  
 9) THE GROUND FLOOR AND SECOND FLOOR
 GROSS AREA CALCS. ARE INCORRECT. PLEASE
 CORRECT.
  
 10) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 11) SPECIFY THE TRUSS BOTTOM CORD LIVE
 LOAD ON THE PLANS. SEE FBC TABLE 1604.1.
  
 12) SUBMIT KEY PLANS AND INSTALLATION
 SCHEDULES FOR THE STORM PANELS.
  
 13) THE MISSLE IMPACT PROTECTION
 INSTALLATION PLAN NEEDS TO BE SIGNED AND
 NOTARIZED. IT MUST ALSO BE APPROVED BY
 THE BUILDING OFFICIAL.
  
 14) SUBMIT ENGINEERING FOR THE BALCONY
 GUARD RAILS.
  
 15) SUBMIT COMPLIANCE LETTER FROM PALM
 BEACH LIFTS.
  
 16) PLEASE SUBMIT TWO COPIES OF ALL
 ITEMS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-09-14 Cont ID  
Sent By dpalmer Date 2006-09-14 Time 09:14 Rev Time 0.00
Received By dpalmer Date 2006-09-14 Time 09:14 Sent To PC
Notes
2006-09-14 00:00:00PLANS HAD TO BE TAKEN ABCK TO ARCHITECT
 ONCE AGAIN TO BE SEALED.
 THE PLANS WERE TURNED AROUND WHEN THEY
 CAME BACK.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-09-11 Cont ID  
Sent By dpalmer Date 2006-09-11 Time 18:25 Rev Time 0.00
Received By dpalmer Date 2006-09-11 Time 18:22 Sent To P
Notes
2006-09-11 00:00:00** UNSAT **
  
 1) NOTE: PLEASE SEE THAT THE RAISED SEAL
 MUST BE CLEAR AND VISABLE WITH ALL
 INFORMATION AS REQUIRED ON SAID SEAL.
 FAC 61G16-1.003 FS 481.221
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-02 Cont ID  
Sent By dpalmer Date 2004-08-02 Time 13:05 Rev Time 0.25
Received By dpalmer Date 2004-08-02 Time 13:05 Sent To  
Notes
2004-08-02 00:00:00STAMPED NEW ELEC SHEETS.
 REDLINED MISSING EQUIPMENT GRNDS 250.122

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-05-04 Cont ID  
Sent By dpalmer Date 2004-05-04 Time 19:46 Rev Time 0.50
Received By dpalmer Date 2004-05-04 Time 19:46 Sent To  
Notes
2004-05-04 00:00:00OK

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2004-08-02 Cont ID  
Sent By mamini Date 2004-08-02 Time 13:38 Rev Time 0.50
Received By mamini Date 2004-08-02 Time 13:38 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2004-05-06 Cont ID  
Sent By mamini Date 2004-05-06 Time 09:10 Rev Time 0.50
Received By mamini Date 2004-05-06 Time 09:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-06-22 Cont ID  
Sent By mcarsill Date 2004-06-22 Time 09:42 Rev Time 0.00
Received By mcarsill Date 2004-06-22 Time 09:42 Sent To  
Notes
2004-06-22 00:00:001) BUILDING ADDRESSES ARE REQUIRED ON
 PROPER LOCATIONS SO POLICE, FIRE AND
 PARAMEDICS CAN FIND THE EMERGENCY.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-05-05 Cont ID  
Sent By mcarsill Date 2004-05-05 Time 11:58 Rev Time 0.00
Received By mcarsill Date 2004-05-05 Time 11:58 Sent To  
Notes
2004-05-05 00:00:001) WET FIRE HYDRANTS ARE REQUIRED
 PRIOR TO, DURING AND AFTER
 CONSTRUCTION.
  
 2) SMOKE DETECTORS MISSING FROM
 BEDROOMS # 2. SECOND FLOOR ELECTRICAL
 PLAN.
  
 3) EGRESS WINDOWS REQUIRED FOR
 SLEEPING ROOMS.
  
 4) PORTABLE FIRE EXTINGUISHERS
 REQUIRED.
  
 5) BUILDING ADDRESSES REQUIRED.
  
 6) ELECTRIC POWERED SMOKE DETECTORS
 ARE REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-09-13 Cont ID  
Sent By adarroug Date 2006-09-13 Time 10:47 Rev Time 0.00
Received By adarroug Date 2006-09-13 Time 10:47 Sent To E
Notes
2006-09-13 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-09-05 Cont ID  
Sent By adarroug Date 2006-09-05 Time 15:08 Rev Time 0.00
Received By adarroug Date 2006-09-05 Time 15:07 Sent To E
Notes
2006-09-05 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-04-12 Cont ID  
Sent By adarroug Date 2005-04-12 Time 11:27 Rev Time 0.00
Received By adarroug Date 2005-04-12 Time 11:27 Sent To B
Notes
2005-04-12 00:00:00TO "RMCDOUGAL" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-02-17 Cont ID  
Sent By adarroug Date 2005-02-17 Time 16:57 Rev Time 0.00
Received By adarroug Date 2005-02-17 Time 16:57 Sent To M
Notes
2005-02-17 00:00:00TO HMOSER DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 16:20 Rev Time 0.00
Received By adarroug Date 2005-02-14 Time 16:20 Sent To B
Notes
2005-02-14 00:00:00TO RMCDOUGAL DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 14:33 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 14:33 Sent To B
Notes
2004-12-14 00:00:00SENT TO "ROB MCD" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 16:47 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 16:47 Sent To B
Notes
2004-11-12 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-11-09 Cont ID  
Sent By csiegber Date 2004-11-09 Time 11:36 Rev Time 0.00
Received By csiegber Date 2004-11-09 Time 11:36 Sent To B
Notes
2004-11-09 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-19 Cont ID  
Sent By csiegber Date 2004-08-19 Time 16:54 Rev Time 0.00
Received By csiegber Date 2004-08-19 Time 16:54 Sent To B
Notes
2004-08-19 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-21 Cont ID  
Sent By csiegber Date 2004-07-21 Time 09:34 Rev Time 0.00
Received By csiegber Date 2004-07-21 Time 09:34 Sent To  
Notes
2004-07-22 00:00:00TO COMM BD#62
2004-07-21 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-16 Cont ID  
Sent By csiegber Date 2004-06-17 Time 11:25 Rev Time 0.00
Received By csiegber Date 2004-06-16 Time 11:25 Sent To  
Notes
2004-06-17 00:00:00TO COMM BD#37

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-21 Cont ID  
Sent By mmclean Date 2004-04-29 Time 13:20 Rev Time 0.00
Received By rmcdouga Date 2004-04-26 Time 10:24 Sent To  
Notes
2004-04-30 00:00:00TO COMM BD#63
2004-04-26 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-03-03 Cont ID  
Sent By pkrauss Date 2005-03-03 Time 13:03 Rev Time 0.40
Received By pkrauss Date 2005-03-03 Time 12:55 Sent To  
Notes
2005-03-03 00:00:00PROVISO:
 DRYER EXHAUST SHALL COMPLY WITH 2001
 FBC(M)504.6 AND TERMINATE IN SUCH A
 MANNER NOT TO BE RECIRCULATED INTO FRESH
 AIR INTAKES OR CREATE A NUISANCE.2001
 FBC(M)401.5.2 AND 501.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-07-09 Cont ID  
Sent By pkrauss Date 2004-07-09 Time 10:41 Rev Time 0.30
Received By pkrauss Date 2004-07-09 Time 10:41 Sent To  
Notes
2004-07-09 00:00:00APPROVED/PLANS STAMPED 6-24-04

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-07 Cont ID  
Sent By pkrauss Date 2004-05-07 Time 07:10 Rev Time 0.55
Received By pkrauss Date 2004-05-07 Time 06:58 Sent To  
Notes
2004-05-07 00:00:00DENIED:
 1.ONLY ONE SET OF MECHANICAL PLANS
 SUBMITTED FOR REVIEW.PER 2001 FBC(M)
 104.2.1, PROVIDE TWO OR MORE COPIES OF
 PLANS AND SPECIFICATIONS.
  
 2.PLANS INDICATE O.A. CALCULATIONS
 PER 2001 FBC(M) 402.2, PROVIDE
 CALCULATIONS ON PLAN.
  
 3.1ST FLOOR "SANTA BARBARA", SOME OF
 THE DUCTS ARE NOT SIZED.INDICATE IF
 THEY ARE "TYPICAL".
  
 4."SANTA BARBARA" DOES NOT INDICATE
 RETURN AIR TO ROOMS SEPARATED BY DOORS.
 SHOW COMPLIANCE WITH REVISED 2001
 FBC(M) 601.4.PLEASE NOTE, ALL RETURN
 AIR INTO THE MASTER SUITE IS TO BE
 INCLUDED IN THE CALCULATION FOR A
 "TOTAL" OF SUPPLY AIR TO THAT SPACE.
  
 5.AC NOTES INDICATE AUXILIARY DRAIN
 PAN WITH FLOAT SWITCH FOR THE 2ND FLOOR
 UNITS ONLY.THIS IS INCORRECT, PER
 2001 FBC(M) 307.2.3, ALL COILS ARE TO
 HAVE PROTECTION.
  
 6.1ST FLOOR DRYER EXHAUST INDICATES
 VENT TO ROOF.PLANS DO NOT INDICATE
 WHAT TYPE OF DUCT WILL BE USED FOR THE
 DRYER EXHAUST.PROVIDE UL LISTING AND
 DETAIL FOR THE PENETRATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-08-25 Cont ID  
Sent By rmcdouga Date 2004-08-25 Time 10:09 Rev Time 0.00
Received By rmcdouga Date 2004-08-25 Time 10:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-07-31 Cont ID  
Sent By kstevens Date 2004-07-31 Time 12:19 Rev Time 1.23
Received By kstevens Date 2004-07-31 Time 12:19 Sent To  
Notes
2004-07-31 00:00:00PASSED/PROVISO
  
 TABLE 909.3 MAX 4 DFU'S ON 2" WET VENT

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-07-03 Cont ID  
Sent By csiegber Date 2004-07-21 Time 09:34 Rev Time 0.50
Received By kstevens Date 2004-07-03 Time 10:38 Sent To  
Notes
2004-07-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FHA-98 DESIGN MANUAL
  
 A) COMMENTS FROM THE PREVIOUS REVIEW
 WERE NOT ADDRESSED, OR NOT ADDRESSED
 PROPERLY.
 1) SHT A-8 SHOW BACKING FOR GRAB BARS AT
 WATER CLOSETS. SEE PAGES 6.4 & 6.5 OF
 THE DESIGN MANUAL. COMMENT RESPONSE
 NOTED, BUT WAS NOT SUFFICIENT.
 2) SHT A-12 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 D) MAXIMUM DFU ON 2" WET VENT IS 4 PER
 TABLE 909.3. MASTER BATH SHOWS 6 DFU'S
 ON 2" PIPE. NO RESPONSE NOTED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-14 Cont ID  
Sent By kstevens Date 2004-05-14 Time 13:49 Rev Time 1.75
Received By kstevens Date 2004-05-14 Time 13:49 Sent To  
Notes
2004-05-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FHA-98 AMEND. DESIGN MANUAL
  
 1) SHT A-8 SHOW BACKING FOR GRAB BARS AT
 WATER CLOSETS. SEE PAGES 6.4 & 6.5 OF
 THE DESIGN MANUAL.
 2) SHT A-12 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, NOR DOES IT
 MEET CODE REQUIREMENTS:
 A) BOTH BATH #2 SHOWER IS SHOWN TO THE
 RIGHT OF THE WATER CLOSET AND LAV TO THE
 LEFT ON THE FLOOR PLAN. SECTION 104.2.1
 B) LAUNDRY TRAY AND WASH MACHINE SHALL
 DISCHARGE DOWNSTREAM OF THE WET VEN FOR
 THE POWDER ROOM PER SECTION 909.1
 C) PER TABLE 906.1 THE MAXIMUM DISTANCE
 FROM THE TRAP TO THE VENT IS 6'. THE
 WASH MACHINE APPEARS TO BE LONGER. THE
 FLOOR LAYOUT INDICATES THAT SEPARATE
 STACKS SHOULD WORK.
 D) MAXIMUM DFU ON 2" WET VENT IS 4 PER
 TABLE 909.3. MASTER BATH SHOWS 6 DFU'S
 ON 2" IN BOTH MASTER BATHS.
 E) LAVS ARE ON SEPARATE WALLS IN MASTER
 BATHS AND REQUIRE SEPARATE STACKS FOR
 EACH. MAXIMUM 5' FROM TRAP TO VENT PER
 TABLE 906.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status N Date 2004-08-10 Cont ID  
Sent By mmclean Date 2004-08-10 Time 11:00 Rev Time 0.00
Received By mmclean Date 2004-08-10 Time 11:00 Sent To  
Notes
2004-08-10 00:00:00NO ZONING REQUIRED FOR RESUB MM

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-29 Cont ID  
Sent By mmclean Date 2004-04-29 Time 13:20 Rev Time 0.00
Received By mmclean Date 2004-04-29 Time 13:20 Sent To I
Notes
2004-04-29 00:00:00OK PER GRACE JOYCE MM


Account Summary | Usage Policy | Privacy Policy