| Plan Review Stops For Permit 04041317 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-10 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-10 |
Time |
09:37 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-06-10 |
Time |
09:37 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-08 |
Time |
19:42 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2004-05-20 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | DENIED | | | BUILDING VALUATION OF $403,950 IS TOO | | | LOW BASED ON SBCCI BUILDING VALUATION | | | DATA. | | | A/C 4338 SF X 76.96 = $333,852 | | | 1777 SF X 41.60 =$73,923 | | | REVISED VALUATION$407,775 | | | ADDITIONAL PERMIT FEES OF $60.05 ARE DUE | | | | | | 2.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR FRONT ENTRY DOOR. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3.FLORIDA STATUTE: 481.221WHEN | | | PLANS ARE SIGNED BY THE ARCHITECT, THEY | | | MUST ALSO BE DATED BY THE ARCHITECT. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-14 |
Time |
16:40 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-10-14 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2005-10-14 00:00:00 | REDLINED LOAD CALCS ON PANEL "A". LOAD | | | IS ACTUALLY LESS THAN SHOWN. SHOULD BE | | | 65% OF 7KW NOT 10KW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-19 |
Time |
11:18 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-09-19 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-30 |
Time |
08:04 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-08-30 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2005-08-30 00:00:00 | ********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE BEEN | | | REVISED WITH "WHITE-OUT" ANDHAND=DRAWN | | | CHANGES. PLEASE SEE THAT ALL CHANGES ARE | | | DONE BY ARCHITECT, REPRINTED AND SIGNED, | | | DATED AND SEALED. FS 481.221 | | | | | | 2)NOTE: PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEW STILL NEED TO BE | | | ADDRESSED. | | | INFORMATION IN TITLE BLOCK. | | | GFI RECEPTS PER 210.8 | | | | | | | | | 3)NOTE: PLEASE SEE RISER DIAGRAM HAS NOW | | | BEEN REVISED, HOWEVER PLANS STILL SHOW A | | | | | | MAIN OUTSIDE? | | | PLEASE ALSO SEE PANELS ARE BEING SHOWN | | | AS BEING FED OVERHEAD.?? | | | PLEASE SEE 230.70, NO MORE THAN 8' OF | | | UNPROTECTED CONDUCTOR MAY BE "INSIDE" | | | HOUSE. | | | PLEASE PROVIDE MAINS AND OVERCURRENT | | | PROTECTION OUTSIDE IF INDEED SERVICE IS | | | BEING FED OVERHEAD TO PANELS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-04 |
Time |
11:59 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-08-04 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2005-08-04 00:00:00 | *********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE 250.6,250.24 | | | "EQUIPMENT GROUNDING" CONDUCTORS ARE NOT | | | INSTALLED FROM METER TO THE FIRST MEANS | | | OF DISCONNECT. | | | PLEASE SEE THIS WAS NOTED ON ALL THREE | | | PREVIOUS REVIEWS AND THIS IS STILL | | | SHOWN. | | | PLEASE SEE THE "EQUIPMENT GROUNDING" | | | CONDUCTORS ARE MISSING FROM MIANS OT | | | SUB-PANELS. | | | 250.110,250.24 SIZED PER 250.122 | | | | | | 2)NOTE: PLEASE SEE MISSING KITCHEN | | | COUNTERSPACE GFI. COUNTERSPACE SHOWN IS | | | MORE THAN 4'. 210.52C1 | | | | | | 3)NOTE: PLEASE SEE POOL SUB PANEL "C" IS | | | NOT SHOWN ON PLANS? | | | PLEASE ALSO CORRELATE PLANS AND RISER. | | | PLANS ONLY INDICATEONE MAIN? | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE POOL SUB PANEL IS | | | SHOWN AS A 200A PANEL WITH A 80A FEED. | | | PLEASE VERIFY IF INDEED PANEL INSTALLED | | | IS A 42 CIRCUIT 200A RATED PANEL? | | | PLEASE SEE RISER DIAGRAM SHOWS 8/0'S FOR | | | FEEDERS AND A #2 EQUIPMENT GROUNDING | | | CONDUCTOR? | | | PLEASE SEE 8/0 IS NOT A WIRE SIZE, ETC | | | 240.4,310.16 | | | PLEASE SEE AWG SHOWN ON PANEL "A" FOR | | | POOL PANEL IS SHOWN AS #4. | | | | | | 5)NOTE: PLEASE CORRELATE LOAD SHOWN ON | | | PANEL "A" FOR POOL SUB PANEL AND LOAD | | | SHOWN ON POOL PANEL "C". | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE MISSING GFI RECEPT | | | REQUIRED W/ IN 3' OF "HIS BATH' LAV. | | | 210.52D | | | | | | 7)NOTE: PLEASE SEE FAC 61G1-16.004, | | | TITLE BLOCK SHALL CONTAIN THE PRINTED | | | ANME AND LICENSE # (AR) OF THE ARCHITECT | | | OF RECORD. | | | THIS WAS NOT ON NOTES FROM REVIEWS LAST | | | YEAR. | | | | | | 8)NOTE: PLEASE SEE MANY ITMES ARE SHOWN | | | AS OPTIONAL ON PLANS?PLEASE KNOW, IF | | | THESE PLANS ARE FOR FINAL/CO, ALL ITEMS | | | INSTALLED SHALL BE SHOWN, ALL ITMES NOT | | | INSTALLED, SHALL BE DELETED. | | | | | | 9)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. PLEASE | | | SHOW THIS LOAD IN ADDITION TO THE 3WATS | | | PER SQ FT. PLEASE SEE THERE ARE OVER 80 | | | RECESSED LTS. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
08:51 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
07:50 |
Sent To |
Z |
|
| Notes |
| 2004-06-17 00:00:00 | ********** REDLINED *********** | | | | | | PLANS/RISER STILL SHOW EQUIPMENT GROUND- | | | -ING CONDUCTORS BEING INSTALLED FROM | | | METER TO DISCONNECTS. | | | THIS WAS NOTED ON PREVIOUS TWO REVIEWS, | | | AN EQUIPMENT GROUNDING CONDUCTOR IS ONLY | | | INSTALLED AFTER THE FIRST MEANS OF | | | DISCONNECT. 250.24,250.6 | | | PLANS HAVE BEEN REDLINED. | | | RECEPT SHOWN FOR DINING RM FLR, NOT AN | | | OPTION, REQ'D PER 210.52 | | | ALL REVISIONS/OPTS ARE TO BE REVIEWED | | | BEFORE ROUGH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-15 |
Time |
14:52 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-06-04 |
Time |
11:35 |
Sent To |
P |
|
| Notes |
| 2004-06-04 00:00:00 | ********** UNSAT *********** | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | WERE NOT ADDRESSED. | | | | | | NOTES: | | | NOTE #1 IS ONLY A NOTE: RISER/PLANS SHOW | | | A MAIN DICONNECTS AND MCB PANELS. MCB | | | PANELS ARE PERMITTED BUT NOT REQUIRED | | | DUE TO HAVING MAIN DISCONNECTS OUTSIDE, | | | HOWEVER IF SHOWN THEN MCB'SWILL BE | | | REQ'D. | | | | | | NOTE #2 ? | | | NOTE #3 NO. | | | NOTE #4 OK | | | NOTE #5 NO | | | NOTE #6 NO | | | NOTE #7 OK | | | NOTE #8 OK | | | NOTE #9 OK. | | | | | | PLEASE BE SURE TO REMOVE OLD/VOIDED | | | SHEETS FROM SETS AND INSERT NEW SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | PLEASE SEE ATTACHED COPY OF FS 553.80(2) | | | (B). THIS NOTICE IS GIVEN ON PLANS WITH | | | SAME COMMENTS AS A NOTICE AFTER SECOND | | | REVIEW. THIS IS ONLY A NOTICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-02 |
Time |
09:52 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-07 |
Time |
06:02 |
Sent To |
M |
|
| Notes |
| 2004-05-07 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER W/ | | | PANELS. PANELS ARE SHOWN AS MCB AND | | | RISER SHOWS MLO? | | | | | | 2)NOTE: PLEASE VERIFY 150A PANELS ARE | | | SHOWN AS 42 CIRCUIT? | | | | | | 3)NOTE: RISER SHOWS EQUIPMENT GROUNDING | | | CONDUCTORS BEING INSTALLED BETWEEN METER | | | AND MAINS/FIRST MEANS IF DISC. | | | PLEASE SEE 250.6, 250.24. THIS IS NOT | | | PERMITTED. ONLY AFTER THE FIRST MEANS OF | | | DISC. | | | | | | 4)NOTE:PLEASE SEE 210.52, 210.52C1 FOR | | | RECEPT SPACING IN TWO RMS AND KITCHEN | | | COUNTER/ DESK AREA. | | | | | | 5)NOTE: PLEASE PROVIDE ROOM DISIGNATION | | | ON PLANS. | | | | | | 6)NOTE: PLEASE SEE AHU#3, SHOWS 8KW | | | W/ 30A OCP. PLEASE SEE 424.3B, MIN OCP | | | FOR HEAT 125% OF KW RATING. | | | | | | 7)NOTE: PLEASE SEE FOYER IS SHOWN AS | | | HAVING A J-BOX. A LT FIXTURE OF SOME | | | SORT WILL BE REQ'D FOR EGRESS LT, 210.70 | | | LS 101 5-8 | | | | | | 8)NOTE: PLEASE SEE THAT SD IN MASTER | | | BEDROOM AREA MUST BE MOVED INTO MASTER | | | BEDRM. PLEASE SEE NFPA-72 FOR INSTALLA- | | | -TION LOCATIONS. 8-1.4.2, 8-1 | | | | | | 9)NOTE: PLEASE SEE FS 481.221, WHEN PLAN | | | -S A RE SIGNED BY THE ARCH, THEY MUST | | | ALSO BE DATED BY ARCH. | | | | | | PLEASE ALSO SEE BLDG REVIEW COMMENTS | | | FOR POSSIBLE BLDG VALUATION ADJUSTMENT. | | | FBC 104.6.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-19 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-19 |
Time |
08:53 |
Sent To |
E |
|
| Notes |
| 2005-09-19 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-25 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-25 |
Time |
08:53 |
Sent To |
E |
|
| Notes |
| 2005-08-25 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-17 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
10:21 |
Sent To |
P |
|
| Notes |
| 2005-08-17 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
| 2005-08-08 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-02 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-02 |
Time |
14:37 |
Sent To |
E |
|
| Notes |
| 2005-08-02 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-15 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-15 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2004-06-15 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-02 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-02 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
| 2004-06-02 00:00:00 | TO DP DESK/RESUB/ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-26 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-26 |
Time |
09:18 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-20 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2004-05-06 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-24 |
Time |
14:35 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-01-24 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-07 |
Time |
06:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-05-10 |
Time |
16:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-08 |
Time |
19:42 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-06-08 |
Time |
19:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-04 |
Time |
11:41 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-05-18 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2004-05-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A-1 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. | | | A) LAUNDRY SINK AND WASH MACHINE SHALL | | | NOT CONNECT TO THE STACK ON A DOUBLE | | | SANITARY TEE. SECTION 706.3. CONNECT THE | | | WASH MACHINE LOWER ON THE STACK THAN THE | | | LAUNDRY SINK. | | | B) CLEAN OUT REQUIRED 4' ABOVE THE | | | FLOOR AT WASH MACHINE. SECTION 708.10 | | | C) TUB NOT VENTED IN BATH #2. SECTION | | | 901.2.1 | | | D) LAV ON RIGHT SIDE OF WATER CLOSET IN | | | POWDER ROOM. | | | E) BAR SINK NOT SHOWN ON FLOOR PLAN. | | | SECTION 104.2.1 | | | F) SEE RED LINE CORRECTIONS ON RISER | | | DIAGRAM. MAKE CORRECTIONS AND RESUBMIT | | | FOR REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
gjoyce |
Date |
2004-06-22 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | DENIED, BY GRACE JOYCE, PLANNER 659-8031 | | | SEE NOTE 1 & 2. | | 2004-06-15 00:00:00 | DENIED, BY GRACE JOYCE, PLANNER 659-8031 | | | - THERE IS A PUBLIC SIDEWALK LOCATED ON | | | PRIVATE PROPERTY.THE OWNER QUIT | | | CLAIMED A PORTION OF THE GOLF COURSE | | | INTO LOT 1.THE SIDE MUST BE MOVED TO | | | APPROVAL AND A NEW SURVEY IS NEEDED. MM | | 2004-05-05 00:00:00 | THERE IS A PUBLIC SIDEWALK LOCATED ON | | | PRIV. PROPERTY.THE OWNER QUIT CLAIMED | | | A PORTION OF THE GOLF COURSE INTO LOT 1. | | | THE SIDE MUST BE MOVED PRIOR TO | | | APPROVAL |
|
|