| Plan Review Stops For Permit 04041280 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-07 |
Time |
14:40 |
Rev Time |
4.00 |
| Received By |
lsmith |
Date |
2004-05-14 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. SUBMIT COPY OF NOTICE OF | | | COMMENCEMENTBEFORE PERMIT IS ISSUED. | | | | | | 2. OWNER/AGENT NEEDS TO SIGN THE ENERGY | | | EFFICIENCY CODE PAGE 1. | | | | | | 3. BALANCE OF PERMIT FEES MUST BE PAID | | | BEFORE PERMIT IS PRINTED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-03 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-03-03 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-02 |
Time |
16:55 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-03-02 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2005-03-02 00:00:00 | ***** UNSAT ***** | | | | | | PLEASE SEE NOTES FROM PREVIOUS REVIEW. | | | | | | PLEASE SEE DISH/DISPOSAL 6KW | | | PLEASE SEE 2KW FOR DINING AND BRKFST | | | RECEPTS. | | | PLEASE SEE 1.2 KW FOR SMALL APPL. | | | | | | SPOKE TO ARCH. WENT OVER EACH ITEM. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-28 |
Time |
10:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-28 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | **** UNSAT **** | | | | | | PLEASE SEE THERE ARE MANY ITEMS ON PANEL | | | SCHEDULES WHICH NEED TO CORRELATE OCP/KW | | | LOAD AND AWG. | | | | | | 1)NOTE: PLEASE SEE MIN #12 20A FOR BATH | | | GFI RECEPT. 210.11C3, 210.52D | | | | | | 2)NOTE: PLEASE SEE MAX KW RATING FOR A | | | 20A CIRCUIT IS 1920W'S. | | | PLEASE ALSO SEE 5KW FOR DRYER SHOWN ON A | | | 1-P 20A CIRCUIT? | | | PLEASE SEE 6KW FOR COOK-TOP ON A 1P-20A | | | BRKR? | | | | | | 3)NOTE: PLEASE SEE POOL PANEL LOAD SHOWN | | | AT 5.2 KW , HOWEVER PANEL "B" INDICATES | | | LOAD AS 6.8 KW. | | | | | | 4)NOTE: PLEASE SEE PLANS INDICATES TWO | | | MAIN DISC'S ON THE OUTSIDE OF HOUSE, | | | HOWEVER RISER DOES NOT SHOW THIS. | | | | | | PLEASE SEE ONE SET OF PLANS HAVE BEEN | | | REDLINED FOR THE ABOVE COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-11 |
Time |
15:19 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-11 |
Time |
15:19 |
Sent To |
P |
|
| Notes |
| 2004-06-11 00:00:00 | ******* REDLINED ******** | | | | | | 1)NOTE: NEW BATH REQUIRED TO HAVE GFI | | | RECEPT PER 210.52D. MUST BVE 20A AND #12 | | | 210.11C3 | | | | | | 2)NOTE: MISSING RECEPT IN BEDRM #3 FOR | | | 2' OF WALL. 210.52 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-03 |
Time |
10:35 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-24 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-24 |
Time |
09:36 |
Sent To |
E |
|
| Notes |
| 2005-02-24 00:00:00 | TO "DP" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
14:34 |
Sent To |
P |
|
| Notes |
| 2004-07-07 00:00:00 | TO KS PERSONALLY/DEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-23 |
Time |
16:12 |
Sent To |
P |
|
| Notes |
| 2004-06-23 00:00:00 | TO KS DESK/REV/PER LM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-08 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2004-06-08 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-04-19 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2004-05-03 00:00:00 | TO SFD RACK/E | | 2004-04-19 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-03 |
Time |
10:35 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-05-03 |
Time |
13:36 |
Sent To |
P |
|
| Notes |
| 2004-05-03 00:00:00 | PASS PRIVISO | | | RETURN AIR IN BEDROOM #4 IS THE WRONG | | | SIZE | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-07 |
Time |
14:40 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-07-07 |
Time |
14:40 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
14:34 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-07-06 |
Time |
17:10 |
Sent To |
B |
|
| Notes |
| 2004-07-06 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SEALED PLANS REQUIRE AN ORIGINAL SIG- | | | NATURE. THE NEW SHEET A4 OF 6 HAS A COPY | | | OF THE ARCHITECT'S SIGNATURE ON ONE COPY | | | AND IS NOT SIGNED/SEALED/DATED AT ALL ON | | | THE OTHER. PLEASE HAVE SHEETS SIGNED/ | | | SEALED AND DATED AS REQUIRED BY FLA. | | | ADMIN. CODE 61G1-16.003 & FS 481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
16:12 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2004-06-20 00:00:00 | PLAN REVIEW, DENIED FBC 2001 | | | PROVIDE ISOMETRIC,SHOW PLUMBING ADDITION | | | QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-11 |
Time |
15:19 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-05-08 |
Time |
06:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-30 |
Time |
17:40 |
Sent To |
I |
|
| Notes |
|
|