Plan Review Details - Permit 04041257
Plan Review Stops For Permit 04041257
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-24 Cont ID  
Sent By jwitmer Date 2004-05-24 Time 11:18 Rev Time 0.77
Received By jwitmer Date 2004-05-24 Time 11:18 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-05-20 Cont ID  
Sent By jwitmer Date 2004-05-20 Time 12:17 Rev Time 1.22
Received By jwitmer Date 2004-05-20 Time 12:17 Sent To PC
Notes
2004-05-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04041257
 ADD: 2600 N FLAGLER# 509
 CONT: MICHAEL RUFINO
 TEL: (561)236-2800
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 PLANS NOT SIGNED OR SEALED BY P.E.!!!!!
 ELECTRICAL COMMENT FROM FIRST REVIEW!!
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-14 Cont ID  
Sent By csiegber Date 2004-05-18 Time 09:02 Rev Time 1.22
Received By jwitmer Date 2004-05-14 Time 09:42 Sent To PC
Notes
2004-05-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04041257
 ADD: 2600 N FLAGLER# 509
 CONT: MICHAEL RUFINO
 TEL: (561)236-2800
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) DEFINITIONS: FL S S 489.105
 BUILDING CONTRACTOR:(B) MEANS A CONTRACT
 OR WHOSE SERVICES ARE LIMITED TO CON-
 STRUCTION OF COMMERCIAL BUILDINGS AND
 SINGLE-DWELLING OR MULTIPLE-DWELLING
 RESIDENTIAL BUILDINGS, WHICH COMMERCIAL
 OR RESIDENTIAL BUILDINGS DO NOT EXCEED
 3 STORIES IN HEIGHT, AND ACCESSORY USE
 STRUCTURES IN CONNECTION THEREWITH OR A
 CONTRACTOR WHOSE SERVICES ARE LIMITED TO
 REMODELING, REPAIRING, OR IMPROVEMENT OF
 ANY SIZE BUILDING IF THE SERVICES DO NOT
 AFFECT THE STRUCTURAL MEMBERS OF THE
 BUILDING.
 THE REPLACEMENT OF EXTERIOR WINDOWS
 AND DOORS IS CONSIDERED AS PART OF THE
 STRUCTURAL ENVELOPE OF THE BUILDING.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) SLIDING GLASS DOORS/ W LARGE MISSLE
 IMPACT TESTING.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3) ADDITIONAL INFORMATION REQUIRED,
 PLANS INDICATE THE USE OF CROWN AND BASE
 WHAT TYPE OF MATERIAL?
 FOAM PLASTIC TRIM 803.4
 FOAM PLASTICS SHALL NOT BE USED AS INTER
 IOR FINISHES.
 EXCEPTION: FOAM PLASTIC TRIM, DEFINED AS
 PICTURE MOLDS, CHAIR RAIL, BASEBOARDS,
 HANDRAILS CEILING BEAMS, DOOR TRIM AND
 WINDOW TRIM, OR CROWN MOLDING SHALL BE
 PERMITTED PROVIDED:
 1) THE MINIMUM DENSITY IS 20 LB/CU FT.
 2) THE MAXIMUM THICKNESS IS 1/2" AND
 THE MAXIMUM WIDTH IS 4".
 3) THE TRIM CONSTITUTES NO MORE THAN
 10% OF THE AREA OF WALL OR CEILING.
 4) THE FLAMESPREAD RATING DOES NOT
 EXCEED 75 WHEN TESTED PER ASTM E 84. THE
 SMOKE DEVELOPMENT RATING IS NOT LIMITED.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2004-05-20 Cont ID  
Sent By dpalmer Date 2004-05-20 Time 12:13 Rev Time 0.25
Received By dpalmer Date 2004-05-20 Time 12:13 Sent To  
Notes
2004-05-20 00:00:00ELECTRICAL PLANS REMOVED FROM REVIEW.
 TO BE SUBMITTED UNDER SEPARATE PERMIT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-04-21 Cont ID  
Sent By csiegber Date 2004-04-16 Time 14:49 Rev Time 0.33
Received By dpalmer Date 2004-04-21 Time 05:26 Sent To  
Notes
2004-04-21 00:00:00*********** UNSAT ********************
  
 1)NOTE: PLEASE SEE PLANS THAT CONTAIN
 A TITLE BLOCK FOR ARCH/ ENGINEER, ARE
 REQ'D UNDER FS 481.221, FS 471.025 TO
 BE SIAGNED, DATED AND SEALED BY THE
 PERSON OF RECORD.
 FBC 104.2.1 PERSON RESPONSIBLE FOR
 PLANS ARE REQ'D TO HAVE THEIR NAME
 AND SIGN.
  
 2)NOTE; PLANS APPEAR TO SHOW ALMOST
 COMPLETE REWIRE OF UNIT. PLEASE SEE
 FBC 34. PLEASE SHOW EITHER EXISTING
 TO MEET CODE OR NEW. LIGHTING?, SD'S?
 ETC.210.70, NFPA-72 8-1.4.1.6.2
  
 3)NOTE: PLEASE SEE 410.8 FOR CLOSET LT.
  
 4)NOTE: PLEASE SHOW MIN CIRCUITING AND
 CORRELATE WITH A SUBMITTED PANEL
 SCHEDULE, SHOWING ALL THE MIN REQ'D
 CIRCUITS PER NEC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-04-22 Cont ID  
Sent By nmccray Date 2004-04-22 Time 14:06 Rev Time 0.00
Received By nmccray Date 2004-04-22 Time 14:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-24 Cont ID  
Sent By ptjomsto Date 2004-05-24 Time 09:05 Rev Time 0.00
Received By ptjomsto Date 2004-05-24 Time 09:05 Sent To  
Notes
2004-05-24 00:00:002ND RESUB GIVEN TO JIM WITMER PT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-18 Cont ID  
Sent By csiegber Date 2004-05-18 Time 09:01 Rev Time 0.00
Received By csiegber Date 2004-05-18 Time 09:01 Sent To B
Notes
2004-05-18 00:00:00TO JW DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-14 Cont ID  
Sent By csiegber Date 2004-05-14 Time 10:12 Rev Time 0.00
Received By jwitmer Date 2004-04-16 Time 14:49 Sent To PC
Notes
2004-04-20 00:00:00TO COMM BD#1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-04-26 Cont ID  
Sent By pkrauss Date 2004-04-26 Time 14:32 Rev Time 0.15
Received By pkrauss Date 2004-04-26 Time 14:26 Sent To  
Notes
2004-04-26 00:00:00NO MECHANICAL PLANS OR INFORMATION
 PROVIDED FOR REVIEW.PLEASE PROVIDE
 INFORMATION WITH MECHANICAL PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-05-14 Cont ID  
Sent By kstevens Date 2004-05-14 Time 10:38 Rev Time 0.25
Received By kstevens Date 2004-05-14 Time 10:37 Sent To  
Notes
2004-05-14 00:00:00PLUMBING PERMIT REQUIRED