| Plan Review Stops For Permit 04041179 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-23 |
Time |
14:11 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-08-23 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2004-08-23 00:00:00 | REVISED SHEETS A2.0, A2.1, A3.0, A6.1 | | | DATED 8/13/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-17 |
Time |
16:09 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-06-17 |
Time |
15:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-14 |
Time |
10:19 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2004-05-14 |
Time |
10:19 |
Sent To |
PC |
|
| Notes |
| 2004-05-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04041179 | | | ADD: 515 N FLAGLER DR# 1200 | | | CONT: HOLT LEE CONSTRUCTION | | | TEL: (954)725-4881 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PLANS DO NOT INDICAE AN ELEVATOR | | | LOBBY. HIGH RISE REQUIRES ALL ROOMS AND | | | ENCLOSURES SHALL HAVE AT LEAST ONE | | | REQUIRED EXIT ACCESSIBLE WITHOUT TRAVEL | | | THROUGH THE ELEVATOR LOBBY.EXIT STAIRWAY | | | CHUTES, JANITOR CLOSETS, GUEST ROOMS, | | | SERVICE ROOMS, ETC, SHALL NOT OPEN INTO | | | THE ELEVATOR LOBBY. | | | SEE 412.6.3 FOR SMOKE DETETORS. | | | | | | 3) ENTRY DOORS TO THE RECEPTION AREA | | | BLOCK THE EGRESS | | | CORRIDOR(1200),1012.1.4DURING ITS | | | SWING, ANY DOOR IN A MEANS OFEGRESS | | | SHALL LEAVE UNOBSTRUCTED AT LEAST1/2 OF | | | THE REQUIRED WIDTH OF THE CORRIDOR. MINI | | | MUM CLEAR WIDTH OF 22" IS REQUIRED. | | | | | | 4) TYPE I/II BUILDING REQUIRES ALL WOOD | | | BACKING OR BLOCKING TO BE FIRE RESISTANT | | | TREATED WOOD, 609.1.2. | | | | | | 5)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 6)11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | DOOR TO OFFICE 1220 REQUIRES 12" ON THE | | | PUSH SIDE, CAGED AREA AND OFICE 1231 | | | REQUIRE 18" PULL SIDE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-26 |
Time |
13:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-26 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-22 |
Time |
07:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-06-22 |
Time |
07:55 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-24 |
Time |
08:32 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-24 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE ATTACHED COPY PRINT/ | | | OUT FROM DBPR. SHOWS LICENSE AS BEING | | | DELINQUENT FOR FIRM. | | | EXPIRED FEB/2003 | | | | | | 2)NOTE: PLEASE PROVIDE A SIGNED, DATED | | | AND SEALED NOTORIZED LETTER FOR | | | SIGNATURE TO HAVE ON FILE. ONCE THIS | | | LETTER IS ON FILE WE WILL NO LONGER NEED | | | LETTER FOR FUTURE REVIEWS. | | | | | | | | | PLEASE SEE FS 471.025 REQUIRES A FULL | | | SIGNATURE CONTAINING A MIN OF FIRST | | | AND LAST NAME. PLEASE SEE THIS IS REQ'D | | | FOR ALL TRADES WHEATHER OR NOT COMMENT | | | IS MADE FROM OTHER REVIEWERS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
06:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-21 |
Time |
06:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-09-14 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-09-14 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-20 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-20 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-16 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-16 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | 1) DEMOLITION, RENOVATION AND | | | CONSTRUCTION SHALL COMPLY WITH | | | NFPA 241. | | | | | | 2) DEMOLITION DEBRIS SHALL BE | | | REMOVED FROM THE BUILDING DAILY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-31 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-31 |
Time |
11:00 |
Sent To |
M |
|
| Notes |
| 2004-08-31 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2004-08-16 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-19 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-19 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | TO COMM BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-14 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-04-16 |
Time |
08:51 |
Sent To |
PC |
|
| Notes |
| 2004-04-16 00:00:00 | TO COMM BD#2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-01 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-09-01 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-31 |
Time |
11:00 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-08-30 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2004-08-30 00:00:00 | DENIED: | | | ONLY ONE COPY OF MECHANICAL REVISION | | | SUBMITTED PER 2001 FBC 104.2.1, A | | | MINIMUM OF 2 COPIES ARE REQUIRED FOR | | | SUBMITTAL. | | | | | | PLEASE NOTE, PLAN SHEETS M-1 & M-3 WERE | | | SUBMITTED FOR REVISION.PLAN WAS CODE | | | COMPLIANT.CITY WILL RETAIN THE ONE | | | APPROVED COPY FOR OUR RECORDS.RESUBMIT | | | ADDITIONAL COPY FOR APPROVAL FOR | | | CONTRACTOR'S COPY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-22 |
Time |
07:59 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-06-08 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-27 |
Time |
07:54 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-04-27 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2004-04-27 00:00:00 | DENIED: | | | PLAN SHEET M-2 INDICATES NEW PVC | | | CONENSATE LINES TO RISER.PVC IS NOT | | | PERMITTED IN THE RETURN AIR PLENUM PER | | | 2001 FBC(M) 602.2.1. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-26 |
Time |
18:52 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-26 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2004-08-26 00:00:00 | REVISION OK - CHANGED LOCATION OF SINK | | | IN BREAKROOM - CHANGED ROUTING OF SANT. | | | AND WATER LINES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-21 |
Time |
18:33 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-06-21 |
Time |
18:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-05 |
Time |
17:19 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-06-05 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2004-06-05 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | CERTIFICATE OF AUTHORIZATION IS DELIN- | | | QUENT. UPDATE CA AND RESUBMIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-28 |
Time |
10:57 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-04-28 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1.0 ALL CAPPED AND DEMO'D PIP- | | | ING SHALL BE INSPECTED PRIOR TO COVERING | | | 2) SHTS A-2.1 AND A-3.0 FLOOR PLAN INDI- | | | CATES DETAIL DETAIL 08 BUT NO DETAIL | | | 08 SHOWN ON SHT A-3O. BREAK ROOM SINK | | | SHALL COMPLY WITH 11-4.24 AND ALL SUB- | | | SECTIONS. PLEASE PROVIDE DETAIL SHOWING | | | CLEAR FLOOR SPACE, HEIGHT AND CLEARANCES | | | EXPOSED PIPES AND SURFACES, ECT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|