| Plan Review Stops For Permit 04041174 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-01 |
Time |
13:38 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-08-01 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-03-08 |
Time |
13:53 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-03-08 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-11-04 |
Time |
09:34 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-11-04 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2004-11-04 00:00:00 | DENIED | | | PRODUCT APPROVALS MISSING FOR WINDOWS. | | | SUBMIT 2 COPIES.TWO DIFFERENT DOOR | | | APPROVALS SUBMITTED, SPECIFY APPROVAL | | | YOU ARE USEING. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2.PRODUCT APPROVALS SUBMITTED REQUIRE | | | A HISTORICAL REVIEW. PLEASE SUBMIT TO | | | HISTORICAL FOR REVIEW PRIOR TO | | | SUBMITTING TO BUILDING DEPARTMENT FOR | | | REVIEW. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-02 |
Time |
13:34 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-07-02 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | DENIED | | | SEE NOTES ATTACHED FROM PREVIOUS REVIEW. | | | NONE OF THE COMMENTS HAVE BEEN ADDRESSED | | | SEE OTHER REVIEWERS NOTES. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-02 |
Time |
09:51 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-04-29 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | DENIED | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.NO PRODUCT APPROVALS SUBMITTED. | | | SUBMIT 2 COPIES FOR, EXTERIOR DOORS, | | | WINDOWS, IMPACT PROTECTION AND ROOFING. | | | | | | 4.ENERGY CALCS NOT SIGNED BY OWNER/AGENT | | | | | | 5.BUILDING VALUATION OF $4,000 IS TOO | | | LOW BASED UPON SBCCI BUIDING VALUATION | | | DATA.VALUE HAS BEEN ADJUSTED AND | | | ADDITIONAL PERMIT FEES ARE DUE. | | | A/C LIVING AREA 150 SF X 76.96=$11,544 | | | OTHER 50SF. X $41.60 = $2080 | | | TOTAL REVISED VALUATION IS $13,642 | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-20 |
Time |
16:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-07-20 |
Time |
16:23 |
Sent To |
P |
|
| Notes |
| 2005-07-20 00:00:00 | PLANS REDLINED 210.11C3 | | | 20A,#12 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-11 |
Time |
16:32 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-04-11 |
Time |
16:17 |
Sent To |
P |
|
| Notes |
| 2005-04-11 00:00:00 | ************ UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE FS 471.025 AND FAC | | | 61G15-23.002, WHICH REQUIRES PLANSTO | | | BE SIGNED WITH AN ORIGINAL SIGNATURE. | | | PLEASE SEE PLANS AHVE NOW COME BACK IN | | | WITH A "RUBBER STAMP" FOR ENGINEER'S | | | SIGNATURE. | | | PLEASE SEE ONE SET IS ONCE AGAIN | | | RETAINED FOR FILE AND WILL NOW BE TURNED | | | OVER TO THE FBPE'S FOR REVIEW OF SAID | | | VIOLATIONS. PLEASE SEE THESE PLANS WILL | | | ALSO BE SENT WITH PREVIOUS RETAINED | | | PLANS AND PLANS FROM OTHER PROJECTS WITH | | | THE SAME COMMENTS. | | | | | | 2)NOTE: PLEASE SEE TITLE BLOCK SHOWS 304 | | | 37TH =ST AND THE ADDRESS IS INDEED, 904 | | | 37TH ST. | | | | | | 3)NOTE: PLEASE SEE THE 4X FEE WHICH WAS | | | ACCESSED ON PREVIOUS REVIEW DUE TO | | | REPEATED CODE COMPLIANCE VIOLATIONS WAS | | | NOT PAID WHEN PLANS WERE RE-SUBMITTED. | | | PLEASE SEE FS 553.80(2)(B) WHICH | | | REQUIRES THIS FEE TO BE PAID "BEFORE" | | | PLANS MAY BE RE-SUBMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
07:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-02-24 |
Time |
07:19 |
Sent To |
P |
|
| Notes |
| 2005-02-24 00:00:00 | ************ UNSAT 3RD REVIEW ********* | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE COME BACK | | | IN W/OUT ANY CHNAGES MADE TO PLANS FOR | | | PREVIOUS COMMENTS FOR CODE COMPLIANCE. | | | PLEASE SEE A NOTICE WAS GIVEN FOR FS | | | 553.80(2)(B) ON PREVIOUS REVIEW. | | | THIS 4X FEE FOR PLAN REVIEWHAS NOW | | | BEEN ACCESSSED TO THE DESIGN | | | PROFESSIONAL. THIS AMOUNT OF $327.40 | | | MUST BE PAID BEFORE PLANS ARE | | | RESUBMITTED. | | | PLEASE SEE ONE SET OF PLANS ARE NOW | | | BEING RETAINED FOR FILE FOR POSSIBLE | | | REVIEW BY THE FBPE'S. | | | | | | PLEASE SEE THE FS 553..80(2)(B) IS NOW | | | ATTACHED ONCE MORE. IFPLANS COME BACK | | | IN AGAIN WITH THE SAME COMMENTS THEN AN | | | ADDITIONAL 4X FEE BE ACCESSED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-27 |
Time |
06:13 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-27 |
Time |
06:11 |
Sent To |
P |
|
| Notes |
| 2004-10-27 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE SAME PLANS WERE | | | SUBMITTED BACK WITHOUT AN CORRECTIONS | | | MADE. SHEETS HAVE BEEN VOIDED. | | | **PLEASE SEE COMMENTS FROM PREVIOUS | | | REVIEW. | | | | | | 2)NOTE: PLEASE SEE ATTACHED COPY OF | | | FS 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONAL. THIS IS A NOTICE GIVEN | | | AT THIS TIME. IF PLANS COME BACK IN | | | WITH ANY OF THE SAME CODE COMMENTS, | | | A 4X FEE SHALL BE ISSUED FOR PLAN | | | REVIEW PORTION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
13:40 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-02 |
Time |
09:51 |
Sent To |
B |
|
| Notes |
| 2004-07-02 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE PLANS NOW HAVE WHITE- | | | -OUT ON PLANS MAKING CHANGES TO SIGNED | | | AND SEALED PLANS . FS 471.025 | | | | | | 2)NOTE: PLEASE SEE REDLINES FROM PRE- | | | -VIOUS PLANS THAT NOW NEED TO BE CORRECT | | | -ED SINCE PLANS ARE GOING BACK OUT. | | | | | | 3)NOTE: PLEASE VERIFY IF SERVICE SHOWN | | | IS NEW OR EXISTING? | | | PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | IF SERVICE IS NEW. | | | | | | 4)NOTE: PLEASE SEE OCP FOR 10KW 424.3B | | | | | | 5)NOTE: PLEASE SEE 210.11C3, 210.70 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
13:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
19:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-16 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-16 |
Time |
15:09 |
Sent To |
P |
|
| Notes |
| 2006-06-16 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-20 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-20 |
Time |
09:40 |
Sent To |
E |
|
| Notes |
| 2005-07-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-01 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-01 |
Time |
09:12 |
Sent To |
E |
|
| Notes |
| 2005-04-01 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
10:09 |
Sent To |
E |
|
| Notes |
| 2005-02-22 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
|
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
13:39 |
Sent To |
E |
|
| Notes |
| 2004-10-25 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-23 |
Time |
09:01 |
Sent To |
P |
|
| Notes |
| 2004-06-23 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
13:28 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
15:26 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-04-26 |
Time |
10:48 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2004-04-27 |
Time |
06:46 |
Sent To |
B |
|
| Notes |
| 2004-04-27 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | FORM 600C INDICATES NO HVAC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2005-07-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-30 |
Time |
14:10 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-30 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-14 |
Time |
06:53 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2005-04-14 |
Time |
06:53 |
Sent To |
B |
|
| Notes |
| 2005-04-14 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ENGINEER SHALL SIGN HIS SIGNATURE. | | | THE SIGNATURE IS A STAMP WHICH IS NOT | | | APPROVED. SEE ELECTRICAL REVIEW. | | | FAC 61G15-23.002 & FS 471.025 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2005-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-05 |
Time |
07:44 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2005-03-05 |
Time |
07:44 |
Sent To |
B1 |
|
| Notes |
| 2005-03-05 00:00:00 | DENIED | | | | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | 1) COMMENT FROM PREVIOUS REVIEW HAS NOT | | | BEEN ADDRESSED. THIS THE THIRD TIME FOR | | | THE SAME COMMENT AND PER FS 553.80(2)(B) | | | AN ADDITIONAL 4 TIMES THE FEE FOR PLAN | | | REVIEW HAS BEEN ADDED FOR THE DESIGN | | | PROFESSIONAL. (ALSO SEE ELECTRICAL | | | REVIEWERS COMMENTS). NO WHITE OUT IS | | | ALLOWED ON THE SIGNED/SEALED/DATED PLANS | | | PER SECTION 104.2.1.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-03 |
Time |
07:56 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-03 |
Time |
07:56 |
Sent To |
B |
|
| Notes |
| 2004-11-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT | | | ADDRESSED. - WHITE OUT IS NOT APPROVED | | | ON PLANS SUBMITTED FOR PUBLIC RECORD AND | | | ON SIGNED AND SEALED PLANS. SECTION | | | 104.2.1.3. | | | 2) SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 553.80(2)(B) | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-27 |
Time |
06:13 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2004-07-01 |
Time |
17:52 |
Sent To |
B |
|
| Notes |
| 2004-07-01 00:00:00 | SIGNED AND SEALED DRAWINGS CANNOT BE | | | ALTERED WITH WHITEOUT.SEE WPB | | | ADMINASTATION CODE SEC.104.2.1.3. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-23 |
Time |
09:01 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
2004-04-24 |
Time |
11:27 |
Sent To |
M |
|
| Notes |
| 2004-04-24 00:00:00 | PLNBING PLAN REVIEW: DENIED FPC 2001 | | | SHOWER COMPARTMENT MINIMUM 30" ,SIDE OF | | | RECTANGLE, INSIDE DEMINSION, SEC 417.4 | | | BATH ROOM: INSIDE DEMINSIONS COMPLY | | | WITH SEC 405,FIXTURE SPACING. | | | ROOM NEEDS TO BE AT LEAST 4" WIDER FOR | | | PROPER SPACING OF PLUMBING FIXTURES. | | | END OF COMMENTS 561-805-6692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
15:26 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|