| Plan Review Stops For Permit 04041127 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2005-05-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-05 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-05 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2005-05-05 00:00:00 | REVISION TO SHEETS A6,A11 AND A12 OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-01 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-01 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | REVISED SHEETS A1,A6,A7,A8,A9,A10,A11 | | | AND A12 ARE OK. ALL BUILDINGS | | | CONSTRUCTED UNDER THIS MASTER ARE | | | REQUIRED TO MATCH THE PLANS AS REVISED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-20 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-20 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | BUILDING REVISIONS DENIED | | | | | | 1) ON SHEET A8 DETAIL 11 ON A11 IS | | | SPECIFIED FOR THE TRUSS CONNECTION. THE | | | CONNECTOR THAT IS SPECIFIED IS A USP | | | HLPA 75, WHICH WAS DELETED FROM THE | | | REVISED CONNECTOR SCHEDULE. ON SHEET A10 | | | A TC-2 CONNECTOR IS SPECIFIED FOR AT THE | | | SAME TRUSS LOCATION. PLEASE CLARIFY. | | | | | | 2) IN SEVERAL LOCATIONS ON SHEET A10 THE | | | LISTED UPLIFT EXCEEDS THE CAPACITY OF | | | THE SPECIFIED TRUSS CONNECTOR. PLEASE | | | CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-17 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-17 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | SHOP DRAWINGS FOR FILIGREE FLOOR SYSTEM | | | ARE OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-09 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-09 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | DENIED | | | | | | 1) THE LIVE LOAD FOR THE BALCONY AREAS | | | CAN NOT BE LESS THAN 60 PSF PER FBC | | | TABLE 1604.1. | | | | | | 2) REDLINE CHANGES TO SIGNED AND SEALED | | | DRAWINGS ARE REQUIRED TO BE INITIALED | | | AND DATED BY THE DESIGNER OF RECORD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-08-26 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-26 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-11 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2004-08-11 00:00:00 | DENIED | | | | | | 1) ON SHEET A-9 THE LOWER ROOF PLAN, THE | | | LEFT SIDE OF THE PLAN DOES NOT MATCH THE | | | TRUSS LAYOUT DRAWING. | | | | | | 2) ON SHEET A-9 THE B7 TRUSS ON THE LEFT | | | SIDE HAS CONNECTORS SPECIFIED THAT DO | | | NOT MEET THE UPLIFTS ON THE TRUSS | | | DRAWINGS. | | | | | | 3) TRUSSES B22, B23, B24 AND B28 ON THE | | | RIGHT SIDE OF SHEET A-9 DO NOT HAVE | | | ADEQUATE CONNECTORS. | | | | | | 4) ON THE SECOND FLOOR ROOF PLAN ON | | | SHEET A-10, THE PLANS INDICATE ONE HIP | | | AND ONE GABLE AT THE FRONT OF THE | | | BUILDING. THE TRUSS LAYOUT SHOWS BOTH AS | | | HIP ROOFS. PLEASE CORRECT. | | | | | | 5) ON A-10 TRUSS A29 HAS AN UPLIFT OF | | | 5345# ON THE TRUSS DRAWINGS AND 5070# ON | | | THE PLANS. | | | | | | 6) THE CONNECTOR FOR TRUSS A12 ON THE | | | RIGHT SIDE OF SHEET A-10, HAS THE WRONG | | | TAG. IT SHOULD BE A TC-8 NOT TC-3. | | | | | | 7) ON A-10 TRUSS A8 HAS A CONNECTOR THAT | | | DOES NOT MEET THE UPLIFT SPECIFIED ON | | | THE TRUSS DRAWINGS. | | | | | | 8) ON A-10 TRUSS A29 HAS AN UPLIFT OF | | | 5070# SPECIFIED AND THE TRUSS DRAWINGS | | | LIST AN UPLIFT OF 5345#. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-10 |
Time |
10:43 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-08-05 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2004-08-05 00:00:00 | TRUSSES DENIED | | | | | | 1) LOWER ROOF PLAN HAS THE CONNECTOR FOR | | | THE AT4 GIRDER TRUSS SPECIFIED IN THE | | | WRONG LOCATION ON SHEET A9. | | | | | | 2) THE UPLIFT IN THE TRUSS DRAWINGS FOR | | | TRUSSES AT16, AT19 AND AT20 EXCEED THE | | | CONNECTORS SPECIFIED FOR THEM ON SHEET | | | A9. | | | | | | 3) THE UPPER ROOF PLAN ON SHEET A10 DOES | | | NOT CORRESPOND TO THE TRUSS LAYOUT. SEE | | | TRUSSES BT 12 AND BT 20 ON LAYOUT. TRUSS | | | BT20 REQUIRES A CENTER BEARING POINT | | | THAT IS NOT SHOWN ON THE PLANS. | | | | | | 4) THE CONNECTORS SPECIFIED FOR TRUSS | | | BT 48 DOES NOT MEET THE REQUIRED UPLIFTS | | | ON THE TRUSS DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-27 |
Time |
13:26 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-07-27 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2004-07-27 00:00:00 | DENIED | | | | | | 1) NO TRUSS DRAWINGS WERE SUBMITTED. | | | | | | 2) THE WRONG PRODUCT APPROVAL WAS | | | SUBMITTED FOR THE ENTRY DOORS. THE ONE | | | SUBMITTED HAS A NON-IMPACT RATED GLAZED | | | STEEL DOOR WITH SIDELITES. THIS DOOR | | | AND SIDELITES ARE REQUIRED TO BE | | | SHUTTERED. | | | | | | 3) IMPACT FEES AND NOTICES OF | | | COMMENCEMENT WILL BE RTEQUIRED FOR EACH | | | PERMIT UNDER THE MASTER. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-06-29 |
Time |
14:05 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
2004-06-29 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. PLEASE | | | SUBMIT THE STATE PRODUCT APPROVAL COVER | | | SHEET WITH THE FL# FOR THE CORRESPONDING | | | NOA. LOCAL OR STATE PRODUCT APPROVAL IS | | | REQUIRED PER FLORIDA STATUES AND RULE 9B | | | -72. NOTE: I PRINTED OUT AND ATTACHED | | | THE STATE COVERSHEETS FOR THE STORM | | | PANELS AND (SGD-9200) SLIDING GLASS DOOR | | | AS AN EXAMPLE. | | | | | | 4) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS FOR EACH | | | OF THE 4 UNITS. | | | | | | 5) THE LETTER FROM PALM BEACH LIFTS HAS | | | THE WRONG PERMIT NUMBER. PLEASE CORRECT. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-05-19 |
Time |
12:53 |
Rev Time |
6.00 |
| Received By |
rmcdouga |
Date |
2004-05-19 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) REVISE PLAN NOTE 10 ON C1. IMPACT | | | PROTECTION IS REQUIRED IN WIND BORNE | | | DEBRIS REGIONS PER FBC 1606.1.4. | | | | | | 4) SPECIFY THAT THE DOORS FROM THE | | | GARAGE TO THE UNITS ARE REQUIRED TO BE | | | 3/4 HOUR FIRE RATED DOORS WITH CLOSERS. | | | SEE FBC 705.1.3. | | | | | | 5) THE WALLS BETWEEN THE GARAGES AND THE | | | HABITABLE SPACE ARE REQUIRED TO BE ONE | | | HOUR FIRE RATED PER FBC 411.2.6 AND 704. | | | | | | 6) THE WALLS BETWEEN THE GARAGES AND THE | | | CONDITIONED SPACE IS REQUIRED TO BE | | | INSULATED PER FBC CHAPTER 13. | | | | | | 7) THE TITLE BLOCKS ON THE PLANS CONTAIN | | | INCORRECT INFORMATION. THE BUILDING | | | NUMBER IS 22 NOT THE LOT NUMBER. THESE | | | PLANS ARE NOT MASTERED. | | | | | | 8) SHOW COMPLIANCE WITH FAIR HOUSING ACT | | | DESIGN MANUAL. SHOW MINIMUM CLEAR FLOOR | | | SPACE AT TOILET OF 48" X 56". CENTER OF | | | TOLIET TO BE 18" OFF WALL. SEE PG.7.43. | | | | | | 9) ALL DOORS IN THE UNITS OTHER THAN THE | | | ENTRY DOOR, PANTRY DOOR AND MECH. ROOM | | | DOOR ARE REQUIRED TO BE USABLE WITH A | | | 32" NOMINAL CLEAR OPENING OF AT LEAST | | | 31-5/8 INCH CLEAR. THIRTY-FOUR INCH DOOR | | | IS REQUIRED FOR DOORS THAT OPEN LESS | | | THAN 180 DEGREES. WALK-IN CLOSET DOORS | | | MUST COMPLY. SEE FHADM PG. 3.5. | | | | | | 10) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT | | | STATE OR LOCAL PRODUCT APPROVALS FOR | | | EXTERIOR WINDOWS, DOORS, ROOFING, GARAGE | | | DOORS, STORM PANELS, TRUSS CONNECTORS, | | | ETC. | | | | | | 11) PRODUCT APPROVAL FOR IMPACT SLIDING | | | GLASS DOOR IS LIMITED TO MAXIMUM WIDTH | | | OF 8' AND DOES NOT WORK FOR 10'WIDE DOOR | | | SPECIFIED ON THE PLANS. | | | | | | 12) SUBMIT KEY PLANS AND INSTALLATION | | | SCHEDULES FOR THE STORM PANLES. | | | | | | 13) THE MISSLE IMPACT PROTECTION | | | INSTALLATION PLAN NEEDS TO BE SIGNED AND | | | NOTARIZED. IT MUST ALSO BE APPROVED BY | | | THE BUILDING OFFICIAL. | | | | | | 14) THE ENGINEERING SUBMITTED FOR THE | | | BALCONY RAILS AND SCREEN DO NOT MATCH | | | THE PLANS. | | | | | | 15) THE LETTER FROM PALM BEACH LIFTS | | | NEEDS TO HAVE AN ORIGINAL SIGNATURE. | | | | | | 16) PLEASE SUBMIT TWO COPIES OF ALL | | | ITEMS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-02 |
Time |
13:14 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2004-08-02 00:00:00 | REDLINED EQUIPMENT GRNDS MISSING. | | | 250.24,250.110 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
06:47 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-21 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-08-02 |
Time |
13:49 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-08-02 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-19 |
Time |
15:00 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-19 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-08-10 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-08-10 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-22 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-22 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2004-06-22 00:00:00 | 1) BUILDING ADDRESSES ARE REQUIRED TO | | | BE POSTED SO POLICE, FIRE AND | | | PARAMEDICAL EQUIPMENT CAN LOCATE THE | | | PROPERTIES IN THE EVENT OF AN | | | EMERGENCY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-28 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-28 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. | | | | | | 2) PORTABLE FIRE EXTINGUISHERS ARE | | | REQUIRED. | | | | | | 3) EGRESS WINDOWS ARE REQUIRED. | | | | | | 4) BUILDING ADDRESSES ARE REQUIRED. | | | | | | 5) ELECTRIC POWERED SMOKE DETECTORS | | | ARE REQUIRED IN THE MASTER SUITES | | | LOCATED ON THE SECOND FLOOR ELECTRICAL | | | PLAN. | | | | | | 6) SMOKE DETECTORS ARE REQUIRED IN | | | FIRST FLOOR MASTER SUITES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-12 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-12 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2005-04-12 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-17 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-17 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
| 2005-02-17 00:00:00 | TO RMCDOUGAL DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
16:41 |
Sent To |
B |
|
| Notes |
| 2005-02-14 00:00:00 | TO RMCDOUGAL/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "ROB MCD" DESK./REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
16:47 |
Sent To |
B |
|
| Notes |
| 2004-11-12 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-09 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-09 |
Time |
11:37 |
Sent To |
B |
|
| Notes |
| 2004-11-09 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-19 |
Time |
16:52 |
Sent To |
B |
|
| Notes |
| 2004-08-19 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-10 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-10 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
| 2004-08-10 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-21 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | TO COMM BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-16 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2004-06-16 00:00:00 | TO COMM BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-04-16 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | TO COMM BD#48 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-03 |
Time |
14:03 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-03-03 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2005-03-03 00:00:00 | PROVISO: | | | DRYER EXHAUST SHALL COMPLY WITH 2001 | | | FBC(M)504.6 AND TERMINATE IN SUCH A | | | MANNER AS NOT TO BE RECIRCULATED INTO | | | FRESH AIR INTAKES OR CREATE A NUISANCE | | | (2001 FBC(M)401.5.2 & 501.3). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-01 |
Time |
08:46 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-01 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-24 |
Time |
09:51 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-24 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2004-04-24 00:00:00 | DENIED: | | | 1.PER 2001 FBC(M) 403.3, OUTSIDE AIR | | | REQUIRED FOR MULTI-FAMILY DWELLINGS IN | | | ACCORDANCE WITH TABLE 403.3. | | | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) 307. | | | 2.3. | | | | | | 3.MECHANICAL PLAN INDICATES AHU | | | LOCATED IN THE LAUNDRY ROOM.PLEASE | | | CLARIFY THE FOLLOWING. (A) DRYER - | | | ELECTRIC OR GAS. (B) IS THERE A DOOR | | | SEPARATING THE AHU FROM THE DRYER (C) IS | | | THE RETURN TO THE AHU DUCTED OR IS THE | | | CLOSET AREA A PLENUM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-31 |
Time |
13:52 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-07-31 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-03 |
Time |
12:20 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-07-03 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2004-07-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DO NOT MEET | | | CODE REQUIREMENTS, NOR DO THE RISERS | | | REFLECT THE FLOOR PLANS.SHT A-14 | | | - CLEANOUTS SHALL BE INSTALLED AT EACH | | | CHANGE OF DIRECTION OF THE BLDG. DRAIN | | | GREATER THAN 45 DEGREES. SECTION 708.3.3 | | | - THERE SHALL BE A CLEANOUT NEAR THE | | | JUNCTION OF THE BLDG. DRAIN AND BLDG. | | | SEWER. (EACH TIME THE BLDG. DRAIN EXITS | | | THE BLDG. - AT KITCHEN AND WHERE THE | | | BATHROOMS EXIT SEPARATELY). SECTION | | | 708.3.5 | | | - RISERS A & B THE SHOWERS ARE NOT VEN- | | | TED IN SECOND BATH. SECTION 901.2.1 | | | - PLUMBING RISERS C & D SHOWER IS NOT | | | TO THE RIGHT OF THE LAV IN BATH #2 AS | | | SHOWN ON THE RISER. | | | - WATER CLOSET IN MASTER BATH DOES NOT | | | SET TO THE RIGHT OF THE TUB AS SHOWN | | | ON RISER. | | | (SUGGESTION: THE PLUMBING CONTRACTOR CAN | | | POSSIBLY INDICATE HOW IT WILL BE INST- | | | ALLED AND DRAW A RISER THAT REFLECTS THE | | | INSTALLATION). | | | 2) SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 553.80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-28 |
Time |
14:09 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-04-28 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-98 DESIGN MANUAL | | | | | | 1) SHT A-2 SHOW CLEAR FLOOR SPACE OF THE | | | WATER CLOSETS AS SHOWN ON PAGE 7.43. - | | | EIGHER 48"X66", 48"X56", OR 60"X56". | | | 2) SHT A-2 WATER CLOSETS IN BATHROOMS | | | SHALL BE 18" OFF WALL. SEE PAGE 7.43, | | | EXAMPLES 1, 2, OR 3. SHOW ON FLOOR PLAN. | | | 3) SHT A-14 PLUMBING RISERS A & B. CLEAN | | | OUTS ARE REQUIRED WHERE BLDG DRAIN EXITS | | | BUILDING AT KITCHEN AND AFTER WASH | | | MACHINE. - SANITARY CROSS FITTINGS ARE | | | NOT APPROVED ON HORIZONTAL BUILDING | | | DRAINS. | | | 4) SHT A-14 PLUMBING RISERS C & D DO NOT | | | REFLECT THE FLOOR PLAN. SHOWER IS NOT TO | | | THE RIGHT OF THE LAV IN BATH #2. KITCHEN | | | SINK IS NOT TO THE RIGHT OF BATH #2. | | | WATER CLOSET IN MASTER BATH DOES NOT SET | | | TO THE RIGHT OF THE TUB. | | | 5) SHT A-14 PLUMBING RISERS C & D. THE | | | WASH MACHINE AND KITCHEN SINK SHALL NOT | | | DRAIN THROUGH THE WET VENTED HORIZONTAL | | | DRAIN FOR BATH #2. SECTION 909.1. | | | THE W/M AND KITCHEN SINK SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT HORIZONTAL | | | DRAIN LINE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-30 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-30 |
Time |
15:42 |
Sent To |
I |
|
| Notes |
| 2004-04-30 00:00:00 | OK PER GRACE JOYCE, PLANNER 659-8031 |
|
|