Plan Review Details - Permit 04040847
Plan Review Stops For Permit 04040847
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-08-18 Cont ID  
Sent By jgomez Date 2004-08-18 Time 16:08 Rev Time 0.33
Received By jgomez Date 2004-08-18 Time 16:08 Sent To PC
Notes
2004-08-18 00:00:00CHECKLIST:
 1-PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 4-29-04. SEE ATTACHED
 COPY.
  
 *FLOOD ZONE REVISION IS OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 BACK JULIO AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-30 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:35 Rev Time 0.33
Received By jgomez Date 2004-06-30 Time 16:37 Sent To PC
Notes
2004-06-30 00:00:001-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON DATE AS
 NOTED ON SBCCI EVALUATION REPORT.
 2-PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 4-29-04.
 3-FLOOD ZONE REVISION IS OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-04-29 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:31 Rev Time 1.00
Received By jgomez Date 2004-04-29 Time 08:57 Sent To PC
Notes
2004-04-29 00:00:00BUILDING REVIEW PROVISO:
 1-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. CLARIFY FASTENER
 SPACING. SEC. 104.2.1.2 CITY AMENDMENT
 2-SECTION A/4: SPECIFY WHERE ARE TABLES
 6 AND 8 FOR ROOF TILE FASTENERS TAKEN
 FROM. SEC. 104.2.1.1 CITY AMENDMENTS.
 3-FLOOD ZONE AO: WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-16 Cont ID  
Sent By dpalmer Date 2004-04-16 Time 10:50 Rev Time 0.25
Received By dpalmer Date 2004-04-16 Time 10:50 Sent To M
Notes
2004-04-16 00:00:00REDLINED SD'S PER NFPA-72 8-1.4.2

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:35 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 14:35 Sent To B
Notes
2004-07-29 00:00:00TO JG DESK/NEW PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-22 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:31 Rev Time 0.00
Received By csiegber Date 2004-06-22 Time 14:31 Sent To B
Notes
2004-06-22 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-29 Cont ID  
Sent By mmclean Date 2004-04-15 Time 09:42 Rev Time 0.00
Received By jgomez Date 2004-04-13 Time 12:41 Sent To PC
Notes
2004-04-15 00:00:00TO SFD RACK/E
2004-04-13 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-26 Cont ID  
Sent By dpalmer Date 2004-04-16 Time 10:50 Rev Time 0.30
Received By pkrauss Date 2004-04-26 Time 08:56 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-04-26 Cont ID  
Sent By pkrauss Date 2004-04-26 Time 08:56 Rev Time 0.25
Received By jleech Date 2004-04-26 Time 19:25 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-15 Cont ID  
Sent By mmclean Date 2004-04-15 Time 09:42 Rev Time 0.00
Received By mmclean Date 2004-04-15 Time 09:42 Sent To I
Notes
***NONE***