| Plan Review Stops For Permit 04040679 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-25 |
Time |
13:46 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-06-25 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-10 |
Time |
15:22 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-06-10 |
Time |
15:22 |
Sent To |
PC |
|
| Notes |
| 2004-06-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04020679 | | | ADD: 2301 CENTREPARK DR# 175 | | | CONT: LEIGHTON MC GINN | | | TEL: (561)863-4455 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND: REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) NOTE 4 FROM PREVIOUS REVIEW, | | | DOOR 119. 1012.4 DURING ITS SWING, ANY | | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST ONE HALF OF THE | | | REQUIRED WIDTH OF A CORRIDOR, PASSAGEWAY | | | OR LANDING. PLANS INDICATE THE PASSAGE- | | | WAY TO BE 4'-0"WIDE. THE DOOR SCHEDULE | | | INDICATES THE DOOR IS 3'-0" WIDE. THE | | | CLEAR FLOOR SPACE LEFT IS 12". THE MINI- | | | MUM CORRIDOR WIDTH IS 36" FOR LESS THAN | | | 50 OCCUPANTS TABLE 1004, FOOTNOTE # 10. | | | THE MINIMUM CLEAR WIDTH WHEN THE DOOR IS | | | OPEN IS 18". THE MINIMUM CORRIDOR WIDTH | | | WOULD BE 4'-6" FOR A OCCUPANT LOAD LESS | | | THAN 50. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-10 |
Time |
13:46 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2004-05-10 |
Time |
13:46 |
Sent To |
PC |
|
| Notes |
| 2004-05-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04040679 | | | ADD: 2301 CENTREPARK DR# 175 | | | CONT: LEIGHTON MC GINN | | | TEL: (561)863-4455 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) SEE DOOR # 105 & 119: | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 4) DOOR# 119: 1012.4 DURING ITS SWING, | | | ANY DOOR IN A MEANS OF EGRESS SHALL | | | LEAVE UNOBSTRUCTED AT LEAST ONE HALF OF | | | THE REQUIRED WIDTH OF AN CORRIDOR, | | | PASSAGEWAY OR LANDING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
19:01 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | PASSED AND STAMPED ELECTRICAL SHEETS | | | PENDING POSSIBLE REVIEW COMMENTS BY | | | OTHER TRADES. (DOORS) SHOWN ON E-SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-28 |
Time |
08:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-28 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2004-05-28 00:00:00 | ******** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | | SAME AS FIRST REVIEW. | | | THIS IS ALSO SHOWN ON ELECTRICAL PLANS. | | | | | | PLEASE HAVE ALL OLD VOIDED SHEETS REMOVE | | | -D AND ONLY INSERT NEW SHEETS TO MAKE | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | ELECTRICAL OK, SEE FIRE COMMENTS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-17 |
Time |
09:48 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-17 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2004-04-17 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | | FOR DOORS OPENING INTO EGRESS. | | | PLEASE SEE THAT THIS COMMENT MAY HAVE | | | AN AFFECT ON LAY OUT AND/OR ELECTRICAL. | | | | | | 2)NOTE: PLEASE INDICATE AIC RATING FOR | | | NEW 200A MAIN AT METER. 110.9 | | | SHOWN FOR NEW PANELS. | | | | | | 3) NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42 ETC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-18 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-18 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-21 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-21 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | 1) DOOR 113 STILL OPENS INTO CORRIDOR | | | 112. THIS DOOR IS APPROXIMATELY THREE | | | FEET WIDE AND THE CORRIDOR IS ONLY FOUR | | | FEET TEN INCHES THUS LEAVING 32 INCHES | | | FOR EXITING. IN BUSINESS OCCUPANICES, | | | FORTY FOUR INCHES IS REQUIRED. ALSO | | | IT APPEARS THAT THE EXIT ROUTE HAS | | | BEEN CHANGED BUT THE ELECTRICAL PLANS | | | STILL SHOW TWO EXIT SIGNS FROM THE | | | WORK AREA/WORK ROOM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-13 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-13 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2004-04-13 00:00:00 | 1) DOORS 113 AND 117 NEARLY BLOCK | | | CORRIDORS 112 AND 118. THE CORRIDORS | | | ARE FOUR FEET WIDE OR 4'-10 AND THE | | | DOORS ARE THREE FEET WIDE, THUS LEAVING | | | ONE FOOT OR ONE FOOT 10 INCHES FOR EXIT | | | ACCESS. | | | | | | 2) SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-17 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-17 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | TO COMM BD#17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-20 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-20 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | TO COMM BD#27 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-10 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-04-12 |
Time |
10:41 |
Sent To |
PC |
|
| Notes |
| 2004-04-12 00:00:00 | TO COMM BD#18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-01 |
Time |
07:39 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-01 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-01 |
Time |
06:39 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-06-01 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2004-06-01 00:00:00 | DENIED: | | | RESPONSE LETTER FROM KAMM CONSULTING: | | | DESIGN CAPACITY IS LESS THAN 2,000 CFM, | | | THEREFORE DUCT SMOKE DETECTORS & ALARM/ | | | STROBE IS NOT REQUIRED. | | | | | | PLEASE PROVIDE MANUFACTURER SUBMITTAL | | | DATA FOR THE CARRIER AHU & CU #4. | | | PROVIDE A LETTER FROM THE MANUFACTURER'S | | | ENGINEER SPECIFYING UNDER NO CONDITIONS | | | WILL THE EQUIPMENT EXCEED 2,000 CFM. | | | THE LETTER SHALL BE SIGNED, SEALED & | | | DATED BY THE ENGINEER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-22 |
Time |
08:26 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-04-22 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2004-04-22 00:00:00 | DENIED: | | | PER 2001 FBC(M) 606.2.1, DUCT SMOKE | | | DETECTORS ARE REQUIRED IN SYSTEMS THAT | | | HAVE THE DESIGN CAPACITY GREATER THAN | | | 2,000 CFM.PROVIDE LETTER FROM | | | MANUFACTURERS ENGINEER INDICATING THAT | | | UNDER NO CIRCUMSTANCE, WILL AHU-4 BE | | | ABLE TO PROVIDE GREATER THAN 2,000 CFM. | | | | | | FAN SHUTDOWN SHALL HAVE NOTIFICATION TO | | | ALARM/STROBE IN NORMALLY OCCUPIED AREAS. | | | 2001 NFPA 90A 6.4.4.3 (1). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-03 |
Time |
14:09 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-07-03 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-26 |
Time |
18:28 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-26 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2004-04-26 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES PER PDI-WH 201 & MANUF | | | INSTALL. INSTRUCTIONS |
|
|