| Plan Review Stops For Permit 04040302 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-21 |
Time |
07:59 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2004-05-21 |
Time |
07:59 |
Sent To |
PC |
|
| Notes |
| 2004-05-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04040302 | | | ADD: 2300 PONCE DE LEON AV | | | CONT: ALTA MANAGEMENT INC | | | TEL: (305)490-9171 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | 104.4.5. SPECIAL FOUNDATION PERMIT | | | WHEN APPLICATION FOR A PERMIT TO ERECT | | | OR ENLARGE A BUILDING HAS BEEN FILED, & | | | PENDING ISSURANCE OF SUCH PERMIT, THE | | | BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR | | | THE FOUNDATION ONLY, UPON WRITTEN RE- | | | QUEST OF THE OWNER AND CONTRACTOR. THE | | | HOLDER OF SUCH A SPECIAL PERMIT IS PRO- | | | CEEDING AT HIS OR HER OWN RISK AND WITH- | | | OUT ASSURANCE THAT A PERMIT FOR THE | | | REMAINDER OF THE WORK WILL BE GRANTED | | | AND THAT CORRECTIONS WILL NOT BE RE- | | | QUIRED IN ORDER TO MEET THE PROVISIONS | | | OF THE TECHNICAL CODE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-07 |
Time |
13:18 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2004-04-07 |
Time |
13:18 |
Sent To |
I |
|
| Notes |
| 2004-04-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04040302 | | | ADD:"THE MARK ANDREW BUILDING" | | | CONT: ALTA MANAGEMENT | | | TEL: (305)490-9171 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) PROVIDE A UNITY OF TITLE TO COMBINE | | | ALL LOTS INTO ONE, THIS WILL ALLEVIATE | | | DIFFICULTIES WITH TABLE 600 AND PROPERTY | | | LINES THROUGH BUILDINGS. | | | RECEIVED 4-28-04 | | | 2) PROVIDE A SITE PLAN SHOWING ALL | | | BUILDINGS SO WE WILL BE ABLE TO ADDRESS | | | EACH BUILDING. NOTE THERE WILL BE ONE | | | SITE ADDRESS AND TENANT ADDRESSES FOR | | | EACH BUILDING. | | | | | | 3) PLANS AND THE SOILS REPORT INDICATE | | | THE PROJECT WILL HAVE A R3 OCCUPANCY, | | | TOWNHOUSE, SHEET A).1 UNDER LAND AREA | | | INDICATES TOWNHOMES, SHEET 2 OF SOILS | | | REPORTALSO REFLECTS THIS PROJECT AS | | | TOWNHOMES AND NOT CONDOMINIMUM AS STATED | | | ON PERMIT APPLICATION. (2) REPORTS ARE | | | SUBMITTED, 3 REQUIRED FOR RESIDENT | | | INSPECTOR. | | | | | | 4) SHEET S-1 COMPONENTS AND CLADDING, | | | EXPOSURE "C" STATED IN PLANS ACTUAL"B" | | | EXPOSUREC AND A BUILDING "MEAN ROOF | | | HEIGHT" OF 35'-40' SEE TABLE 1606.2D | | | MULTIPLIER SHOULD BE 1.49, ALL PRESSURE | | | ZONES ON PLAN ARE LOW, EVEN LOW WHEN | | | FIGURED AS "B" ZONE. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | AT THIS TIME A REVIEW FOR THE FOUNDATION | | | CAN NOT BE COMPLETED. ON ISSUANCE OF A | | | FOUNDATION PERMIT THIS CAN NOT BE | | | CONSTRUED THAT A BUILDING PERMIT WILL BE | | | ISSUED. THE CONTRACTOR IS WORKING AT HIS | | | OWN RISK. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
18:11 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | FOR SLAB/UNDERGROUND ELECTRICAL | | | CONDUITS ONLY. | | | FOOTER STEEL GE. 250.66 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-20 |
Time |
17:21 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-20 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2004-04-20 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 AND | | | FS 471.023 | | | PLEASE INCLUDE ALL INFORMATION ON TITLE | | | BLOCK AS REQ'D. THIS IS TO INCLUDE | | | CERTIFICATE OF AUTHORIZATION #. | | | PLEASE ALSO HAVE PLANS SIGNED BY | | | ENGINEER WITH COMPLETE SIGNATURE CONTAIN | | | -ING AMIN OF FIRST AND LAST NAME AS | | | SHOWN ON LICENSE. FS 471.025 | | | INITIALS ARE NOT ACCEPTABLE PER FBPE'S. | | | PLEASE SEE THAT THE ABOVE IS REQ'D | | | WEATHER OR NOT COMMENT IS MADE BY OTHER | | | REVIEWERS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-19 |
Time |
09:12 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-19 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-05 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | TO COMM BD#52 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
10:43 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-05 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-07 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | 4/7/04 TO Z | | | TO COMM BD#37 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-14 |
Time |
16:16 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-05-14 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | FOUNDATION PERMIT ONLY.UNDERGROUND | | | REFRIGERANT LINES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-19 |
Time |
09:07 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-19 |
Time |
09:07 |
Sent To |
ENG |
|
| Notes |
| 2004-04-19 00:00:00 | *************FOUNDATION ONLY************ | | | | | | PERMIT WILL BE FOR THE UNDERGROUND | | | REFRIGERANT & SUCTION LINES ONLY | | | (PER PLAN). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-15 |
Time |
10:20 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-15 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2004-05-15 00:00:00 | FOUNDATION WORK ONLY | | | | | | | | | 104.4.5. SPECIAL FOUNDATION PERMIT | | | WHEN APPLICATION FOR A PERMIT TO ERECT | | | OR ENLARGE A BUILDING HAS BEEN FILED, & | | | PENDING ISSURANCE OF SUCH PERMIT, THE | | | BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR | | | THE FOUNDATION ONLY, UPON WRITTEN RE- | | | QUEST OF THE OWNER AND CONTRACTOR. THE | | | HOLDER OF SUCH A SPECIAL PERMIT IS PRO- | | | CEEDING AT HIS OR HER OWN RISK AND WITH- | | | OUT ASSURANCE THAT A PERMIT FOR THE | | | REMAINDER OF THE WORK WILL BE GRANTED | | | AND THAT CORRECTIONS WILL NOT BE RE- | | | QUIRED IN ORDER TO MEET THE PROVISIONS | | | OF THE TECHNICAL CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-27 |
Time |
17:12 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-27 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2004-04-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FHA-98 DESIGN MANUAL | | | | | | 1) MORE INFORMATION REQUIRED TO DO A | | | REVIEW. | | | 2) A SANITARY RISER DIAGRAM AND A WATER | | | RISER DIAGRAM ARE REQUIRED PER SECTION | | | 104.3.1.1 | | | 3) REQUIREMENTS FOR FHA REQUIRED FOR | | | REQUIREMENTS 7 & 7B. | | | 4) INITIALS ARE NOT ACCEPTABLE FOR THE | | | SIGNATURE OF THE ENGINEER. FAC G1G15-23. | | | 002(1) - FS 471.025 - FBPE'S STATES | | | FIRST & LAST NAME REQD. | | | 5) CERTIFICATE OF AUTHORIZATION REQD PER | | | 61G15-23.002(2) - FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-05-04 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | | | | | | | | | | | | | APPROVED BY JOSH LONG | | | | | | | | | | | | | | | | | | | | | | | | A |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-16 |
Time |
10:34 |
Sent To |
I |
|
| Notes |
| 2004-04-16 00:00:00 | DENIED, BY JOSH LONG, PLANNER 659-8031 | | | NEED TO COMPLY WITH 1.8 OF AGREEMENT: | | | THE APPLICANT SHALL COMMENCE THE PARK | | | IMPROVEMENTS PRIOR TO THE ISSUANCE OF | | | THE FIRST BUILDING PERMIT.ALL | | | IMPROVEMENTS TO THE PARK SHALL BE | | | COMPLETED PRIOR TO THE ISSUANCE OF THE | | | FIRST CERTIFICATE OF OCCUPANCY FOR THE | | | PLANNED DEVELOPMENT.CALLED CONTR |
|
|