| Plan Review Stops For Permit 04031573 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-05-13 |
Time |
09:42 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-05-13 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-04-15 |
Time |
17:23 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-05-03 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2004-05-03 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | WWW.FLORIDABUILDING.ORG | | | | | | 2. BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PERMIT SET OF PLANS | | | MUST BE STAMPED BY THAT OFFICE AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO | | | THE PERMIT APPLICATION. IF ANY | | | QUESTIONSABOUT THE | | | IMPACT FEES PLEASE CALL 233-5025. | | | | | | 3. A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BEISSUED. | | | | | | THE VALUE OF THE HOUSE HAS BEEN UPGRADED | | | AND ADDITIONAL FEES ARE DUE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
13:43 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
13:43 |
Sent To |
P |
|
| Notes |
| 2004-05-08 00:00:00 | ******* REVISION/ PROVISO ********* | | | | | | 1)NOTE: PLANS NOW HAVE BEEN RESUBMITTED | | | SHOWINGPANELS AS MCB, HOWEVER PANEL | | | SCHEDULES SHOW PANELS MLO? | | | PLANS ALSO NOW INDICATE A POOL PANEL, | | | WHICH WAS NOT ON ORIG PLANS AND IS NOT | | | ON RISER DIAGRAM. | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | PLANS TO BE REVISED AND SUBMITTED FOR | | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | | -ION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
10:50 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-09 |
Time |
16:16 |
Sent To |
M |
|
| Notes |
| 2004-04-13 00:00:00 | ********** UNSAT *************** | | | | | | 1)NOTE: PLEASE PROVIDE ALL LICENSE #`S | | | ON TITLE BLOCKS AS REQ'D UNDER FS/ FAC | | | 481.219/ 61G1-16.004 | | | | | | 2)NOTE: PLEASE SEE 250.66 FOR SIZING | | | OF MAIN GROUNDING ELECTRODE CONDUCTOR. | | | | | | 3)NOTE: PLEASE SEE 210.63 FOR MISSING | | | RECEPT FOR A/C UNITS. | | | | | | 4)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS, MASTER BEDROOM, BR# 4 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-07 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
| 2004-05-07 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-07 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-30 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | 03/30/2004TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-13 |
Time |
11:42 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-13 |
Time |
14:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-10 |
Time |
08:14 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | REVIEW APPROVED BY JOHN LEECH, SEE | | | REVISED SHEET A-6 LM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-13 |
Time |
15:13 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-04-15 |
Time |
17:22 |
Sent To |
B |
|
| Notes |
| 2004-04-15 00:00:00 | DENIED; | | | BIDET NOT VENTED. BATH #2 SHR. UNVENTED | | | W/M MUST TIE INTO VENT STACK BELOW L.T. | | | SEE SHT 6 SANITARY RISER DIAGRAM MARKED | | | IN RED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-01 |
Time |
10:46 |
Sent To |
I |
|
| Notes |
|
|