Plan Review Details - Permit 04031557
Plan Review Stops For Permit 04031557
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-12 Cont ID  
Sent By alange Date 2004-05-12 Time 11:11 Rev Time 1.00
Received By alange Date 2004-05-12 Time 11:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-29 Cont ID  
Sent By csiegber Date 2004-05-10 Time 07:39 Rev Time 2.25
Received By alange Date 2004-04-29 Time 12:25 Sent To  
Notes
2004-04-29 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BUILDING VALUATION TOO LOW BASED ON
 SBCCI BUILDING VALUATION DATA.
 1224 SF X $76.96 = $94,199
 471 SF X $41.60 = $19,593
 REVISED VALUE IS $113,792.ADDITIONAL
 PERMIT FEE OF $510.58 IS DUE.
  
 4.SAFTEY GLAZING REQUIRED IN HALL
 BATHROOM PER FBC 2405.2.
  
 5. SPECIFY SIZES OF BEDROOM EGRESS
 WINDOWS AND LAWSON WINDOW NUMBER.
  
 6. PRODUCT APPROVAL FOR LAWSON 9000
 SERIES SLIDING DOOR NOT LISTED ON THE
 DCA PRODUCT APPROVAL SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-08 Cont ID  
Sent By btrobaug Date 2004-04-08 Time 07:57 Rev Time 0.50
Received By btrobaug Date 2004-04-07 Time 18:21 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-05-10 Time 07:39 Rev Time 0.00
Received By csiegber Date 2004-05-10 Time 07:39 Sent To B
Notes
2004-05-10 00:00:00TO AL DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-06 Cont ID  
Sent By mmclean Date 2004-05-07 Time 11:23 Rev Time 0.00
Received By csiegber Date 2004-05-06 Time 16:19 Sent To Z
Notes
2004-05-06 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-29 Cont ID  
Sent By mmclean Date 2004-04-29 Time 12:36 Rev Time 0.00
Received By alange Date 2004-03-30 Time 14:06 Sent To  
Notes
2004-04-01 00:00:003/30/2004 TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-12 Cont ID  
Sent By btrobaug Date 2004-04-08 Time 07:57 Rev Time 0.40
Received By pkrauss Date 2004-04-12 Time 08:42 Sent To P
Notes
2004-04-12 00:00:00PROVISO:
 RETURN AIR DUCT FROM THE MASTER BEDROOM
 SHALL BE A MINIMUM OF 12" PER THE
 REVISED 2001 FBC(M) 601.4 EXCEPTION #1
 & 3.ALL SUPPLY AIR INTO THE MASTER
 SUITE TO BE INCLUDED FOR A "TOTAL" OF
 SUPPLY AIR INTO THE SUITE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-04-12 Cont ID  
Sent By pkrauss Date 2004-04-12 Time 09:10 Rev Time 0.33
Received By jleech Date 2004-04-12 Time 18:44 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-05-07 Cont ID  
Sent By mmclean Date 2004-05-07 Time 11:23 Rev Time 0.00
Received By mmclean Date 2004-05-07 Time 11:23 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-04-01 Cont ID  
Sent By csiegber Date 2004-05-06 Time 16:19 Rev Time 0.00
Received By mmclean Date 2004-04-01 Time 11:19 Sent To I
Notes
2004-04-01 00:00:00DENIED, NEED TO PROVIDE ALL 5 RELEASES
 FOR FENCE AND TOO MUCH CONCRETE IN FRONT
 SETBACK CALLED OWNER FILE M MM
 CONTRACTOR WILL INDICATE THAT THE WALL
 & FENCE ARE EXISTING. MM