Plan Review Details - Permit 04031325
| Plan Review Stops For Permit 04031325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-19 |
Time |
15:32 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2004-04-19 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04031325 | | | ADD: 2800 N FLAGLER/ 406 | | | CONT: NDS CONSTRUCTION | | | TEL: (561)236-5187 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: APPROVED/ PROVISO | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) TYPE I OR II BUILDING, 609.2.1 | | | PARTITIONS AND BACKING SHALL BE NON | | | COMBUSTIBLE OR FIRE RETARDANT TREATED | | | WOOD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-05-03 |
Time |
10:52 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
05:47 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | ********* NOTES REDLINED ******** | | | | | | | | | CABINETS ARE NOT PERMITTED TO GO BACK | | | INFRONT AND AROUND PANEL IN VIOLATION | | | OF 110.26 | | | SPOKE TO CHIEF ELECTRICAL INSPECTOR, | | | AND UNDERSTOOD ONLY COUNTERTOPS WERE | | | BEING REPLACED, WHEN EXPLAINED KITCHEN | | | HAD DEMO PERMIT AND ALL CABINETS ETC | | | ARE NEW, 110.26 STANDS. | | | PLANS SHOW CREATING YOUR OWN VIOLATION | | | AND PLANS ARE CLEARLY REDLINED THAT | | | PANEL MUST MEET 110.26!! | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-01 |
Time |
16:04 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-13 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2004-04-13 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: PLANS SHOW ELECTRICAL PANEL | | | AS EXISTING IN KITCHEN AND NEW CABINETS | | | ETC BEING INSTALLED INFRONT. THIS WILL | | | NOT BE PERMITTED UNDER 110.26 NEC. | | | MUST MEET CLEARENCE REQ'MENTS. | | | PLEASE VERIFY AND/OR MOVE LOCATION OF | | | PANEL. | | | | | | 2)NOTE: PLEASE PROVIDE SIZE AND LOAD | | | ON PANEL WITH NEW CIRCUITS BEING ADDED. | | | 215.5/220 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2004-04-22 00:00:00 | TO COMM BD. #8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-25 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-25 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | TO COMM BD#47 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-29 |
Time |
14:12 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-04-29 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-01 |
Time |
16:02 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
2004-04-01 |
Time |
16:02 |
Sent To |
E |
|
| Notes |
| 2004-04-01 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | ALL DRAWINGS SHALL BEAR THE NAME AND THE | | | SIGNATURE OF THE PERSON RESPONSIBILE FOR | | | THE DESIGN. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
|