Plan Review Details - Permit 04031143
Plan Review Stops For Permit 04031143
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-06-21 Cont ID  
Sent By lsmith Date 2004-06-21 Time 08:09 Rev Time 0.50
Received By lsmith Date 2004-06-21 Time 08:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-06-03 Cont ID  
Sent By lsmith Date 2004-06-03 Time 10:33 Rev Time 0.50
Received By lsmith Date 2004-06-03 Time 10:33 Sent To  
Notes
2004-06-03 00:00:00SLAB HAS BEEN ADDED TO THE PLANS BUT NO
 ANCHOR DETAIL HAS BEEN ADDED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-05-10 Cont ID  
Sent By dpalmer Date 2004-06-03 Time 08:21 Rev Time 0.50
Received By lsmith Date 2004-05-10 Time 09:37 Sent To  
Notes
2004-05-10 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. SEE NOTES FROM FIRST REVIEW: STILL NO
 IN FORMATION ON THE METHOD OF
 PROTECTING THE POOL FROM THE OPENINGS OF
 THE HOUSE.
 2. SHOW TYPE OF ANCHORS USED TO SECURE
 POOL EQUIPMENT TO CONCRETE SLAB. SEE
 NOTE #5 ON PLUMBING REVIEW.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-01 Cont ID  
Sent By pschmitz Date 2004-05-08 Time 10:38 Rev Time 0.50
Received By lsmith Date 2004-04-01 Time 08:46 Sent To  
Notes
2004-04-01 00:00:00SHOW METHOD OF PROTECTING THE POOL FROM
 THE OPENINGS IN THE HOUSE PER FBC
 CHAPTER 24 & POOL SAFETY ACT.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-15 Cont ID  
Sent By dpalmer Date 2004-06-15 Time 08:04 Rev Time 0.33
Received By dpalmer Date 2004-06-15 Time 08:04 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-06-03 Cont ID  
Sent By csiegber Date 2004-06-09 Time 14:25 Rev Time 0.75
Received By dpalmer Date 2004-06-02 Time 16:59 Sent To B
Notes
2004-06-03 00:00:00******** UNSAT *********
  
 1)NOTE: PLEASE SEE PLANS ARE SUBMITTED
 WITH NO CHANGES TO WIRING DIAGRAM.
 HANDDRAWN PLANS ARE NOW SUBMITTED BY
 ELECTRICAL CONTRACTOR WHICH ARE PERMITT-
 -ED. TIME CLOCK IS MISSING AS REQ'D
 UNDER FBC.
  
 2)NOTE: PLANS/PAPERWORK THAT IS SIGNED
 AND SEALED BY THE ENGINEER MUST CONTAIN
 A TITLE BLOCK PER FAC61G15-23.002
 PLEASE ALSO SEE THERE ARE SHEETS IN
 SET THAT THE ENGINEER HAS AFFIXED HIS
 SIGNATURE AND SEAL WHICH HE CAN NOT DO
 PER FS471.025
  
  
 PER REQUEST FROM FBPE'S ONE SET HAS
 BEEN RETAINED. THESE PLANS WILL BE SENT
 TO TO FBPE'S PER THEIR REQUEST.
  
 PLEASE SUBMIT TWO NEW CLEAN SETS, SIGNED
 DATED AND SEALED.
 PLEASE SUBMIT TWO CLEAR SETS FOR REVIEW
 AND STAMPING
 SUBMIT TWO SETS FOR ELECTRICAL TO
 INCLUDE REQ'D TC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-04-23 Cont ID  
Sent By csiegber Date 2004-05-27 Time 11:02 Rev Time 0.33
Received By dpalmer Date 2004-04-23 Time 15:30 Sent To P
Notes
2004-04-23 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE SHOW NEW HEAT PUMP ON
 WIRING DIAGRAM. THIS IS NOT SHOWN.
  
 2)NOTE: PLEASE PROVIDE LOAD CALCULATION
 FOR EXISITNG SERVICE AND INCLUDE ALL
 NEW LOADS. PLEASE ALSO INDICATE SIZE
 OF EXSITING SERVICE..
  
 THESE ARE NEW COMMENTS AND SHOULD HAVE
 BEEN REQUESTED ON ORIG REVIEW. IF PLANS
 COME BACK WITH THESE AS THE ONLY COMMENT
 -S, A RESUB FEE WILL NOT BE DUE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-30 Cont ID  
Sent By alange Date 2004-04-22 Time 10:55 Rev Time 0.25
Received By btrobaug Date 2004-03-30 Time 06:50 Sent To P
Notes
2004-03-30 00:00:00 
 PLEASE NOTE THAT THE SIGNATURE OF THE EN
 GINEER IS REQUIRED ON HIS/HER SEAL PER
 61G15-23.002 FLORIDA ADMINISTRATIVE CODE
 INITIALS ARE NOT ACCEPTABLE PER F.B.P.E.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-09 Cont ID  
Sent By csiegber Date 2004-06-09 Time 14:25 Rev Time 0.00
Received By csiegber Date 2004-06-09 Time 14:25 Sent To E
Notes
2004-06-09 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-27 Cont ID  
Sent By csiegber Date 2004-05-27 Time 11:02 Rev Time 0.00
Received By csiegber Date 2004-05-27 Time 11:02 Sent To E
Notes
2004-05-27 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 10:55 Rev Time 0.00
Received By alange Date 2004-04-22 Time 10:55 Sent To E
Notes
2004-04-22 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-29 Cont ID  
Sent By lsmith Date 2004-03-29 Time 13:58 Rev Time 0.00
Received By lsmith Date 2004-03-29 Time 13:58 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-22 Cont ID  
Sent By mmclean Date 2004-03-26 Time 12:51 Rev Time 0.00
Received By csiegber Date 2004-03-22 Time 11:28 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-08 Cont ID  
Sent By dpalmer Date 2004-06-15 Time 08:04 Rev Time 1.00
Received By pschmitz Date   Time   Sent To B
Notes
2004-05-08 00:00:00PROVISO: BACK FLOW PREVENTER PIOR TO
 COMMENCING WORK.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By dpalmer Date 2004-04-23 Time 15:31 Rev Time 0.50
Received By kstevens Date 2004-03-31 Time 16:46 Sent To B
Notes
2004-03-31 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW.
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 4) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (DETAIL OR ADD TO NOTES)
 5) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 6) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 7) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 8) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 9) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 10) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 11) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 12) PIPING SCHEMATIC DOES NOT REFLECT
 THE POOL LAYOUT OR THE SPECIFICATIONS
 LIST. NO VACUUM LINE SHOWN ON THE PIPING
 SCHEMATIC.
 13) PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-26 Cont ID  
Sent By csiegber Date 2004-03-22 Time 11:28 Rev Time 0.00
Received By mmclean Date 2004-03-26 Time 12:51 Sent To I
Notes
***NONE***