| Plan Review Stops For Permit 04031091 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-10 |
Time |
08:04 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2004-06-10 |
Time |
07:34 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-01 |
Time |
11:19 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2004-05-13 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04031091 | | | ADD: 801 VILLAGE BLVD/ 307 | | | CONT: STORETECH INC | | | TEL: (561)901-1937 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | A) THEPLANS INDICATE A EXPOSURE "C", | | | THE BUILDING IS LOCATED IN A "B" WIND | | | EXPOSURE, YOU MAY DESIGN TO THE MORE | | | RESTRICTIVE "C" ZONE BUT THE MULTIPLIER | | | OF 1.21 WILL BE USED FOR WIND PRESSURES. | | | | | | NOTE NO PRODUCT APPROVALS HAVE BEEN SUB- | | | MITTED 1ST OR 2ND REVIEW!! | | | | | | B) THE INTERNAL PRESSURE COEFFICIENT | | | IS ALSO INCORRECT, IT SHOULD BE .18 FOR | | | ENCLOSED STRUCTURES. | | | | | | 2) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) FIXED STOREFRONT WINDOWS | | | B) STOREFRONT DOORS | | | C) STORM SHUTTERES REQUIRED IF GLAZING | | | HAS NOT MET LARGE MISSLE IMPACT | | | TESTING. | | | | | | 3) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 5) ******REMOVE ALL VOIDED SHEETS FROM | | | PLANS******* RETAIN (1) SET OF VOIDED | | | PAGES. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-09 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-04-09 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2004-04-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04031091 | | | ADD: 801 VILLAGE BLVD# 307 | | | CONT: RCC ASSOCIATES | | | TEL: (954)325-7273 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 2) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) FIXED STOREFRONT WINDOWS | | | B) STOREFRONT SWING DOORS | | | C) STORM SHUTTERS IF GLAZING NOT TESTED | | | FOR LARGE MISSLE IMPACT. | | | | | | 3)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | 5) CHANGES IN LEVEL 11-4.5.2 CHANGES IN | | | LEVEL UP TO 1/4 IN. MAY BE VERTICAL AND | | | WITHOUT EDGE TREATMENT. CHANGES IN LEVEL | | | BETWEEN 1/4IN AND 1/2IN SHALL BE BEVELED | | | WITH A SLOPE NO GREATER THAN 1:2. | | | CHANGES GREATER THAN 1/2IN SHALL BE | | | ACCOMPLISHED BY MEANS OF A RAMP THAT | | | COMPLIES WITH 11-4.7 OR 11-4.8. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
15:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-14 |
Time |
07:19 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-04-14 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2004-04-14 00:00:00 | *************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | | ALL INFORMATION REQ'D ON TITLE BLOCK FOR | | | ENGINEER AND ENGINEERING FIRM. | | | PLEASE INCLUDE NAME(S) AND ALL LICENSE | | | #'S AS REQ'D INCLUDING CA#. | | | PLEASE BE SURE RAISED SEALED IS CLEAR | | | AND VISABLE.PLEASE SEE PLUMB REVIEW FOR | | | THIS COMMENTALSO. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE "B" | | | INDICATES SHOW WINDOW AND SIGN CIRCUIT | | | AS SEPARATE YET, PLANS INDICATE BOTH ON | | | CIRCUIT B-9? PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS MAY BE REQ'D BY | | | OTHER TRADES TO VERIFY PREVIOUS. | | | PLEASE SEE OTHER REVIEWERS NOTES. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 5)NOTE: PLEAS VERIFY LOCATION OF NEW | | | MAIN DISC? PLEASE ALSO VERIFY WHERE | | | NEW MAIN IS BEING FED FROM? SAME FPL | | | TRANSFORMER? 230.72, 230.2 | | | | | | 6) NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42 ETC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-08-05 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-08-05 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2004-08-05 00:00:00 | REVISION TO FIRE SPRINKLER PLAN PERMIT # | | | 04060220 DATED 7-19-04 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-14 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-26 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-26 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2004-03-26 00:00:00 | 1) ALL DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEMOLITION DEBRIS IS TO BE | | | REMOVED FROM THE BUILDING DAILY. | | | | | | 3) FIRE SPRINKLER HEADS ARE REQUIRED | | | IN THE WALK-IN COOLERS AND FREEZERS. | | | | | | 4) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
14:17 |
Sent To |
FIRE |
|
| Notes |
| 2004-07-22 00:00:00 | REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-01 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-01 |
Time |
11:19 |
Sent To |
B |
|
| Notes |
| 2004-06-01 00:00:00 | TO JW DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-05 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | TO COMM BD#56 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-19 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-19 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2004-03-19 00:00:00 | COMM BD#33 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-26 |
Time |
10:17 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-11 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-10 |
Time |
12:39 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2004-04-10 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2004-04-10 00:00:00 | PROVISO: | | | ROOF CURB SHALL BE A MINIMUM OF 8" | | | ABOVE THE ROOF SURFACE PER 2001 FBC | | | 1511.7. | | | | | | PLEASE PROVIDE INFORMATION ON THE | | | CONDENSATE; LINE SIZE, PIPE MATIERIAL | | | AND TERMINATION.PER CITY CODE SECTION | | | 90-125 (5), CONDENSATE SHALL TERMINATE | | | TO STORM DRAIN NOT THE SANITARY. PLEASE | | | CLARIFY. | | | | | | SEPARATE PERMIT REQUIRED FOR WALK-IN | | | COOLER/FREEZERS AND COOLERS WITH REMOTE | | | CONDENSERS.PROVIDE MANUFACTURER | | | SUBMITTAL DATA WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-26 |
Time |
10:16 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-05-26 |
Time |
10:16 |
Sent To |
M |
|
| Notes |
| 2004-05-26 00:00:00 | SEPARATE GAS PLANS AND PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-05-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-22 |
Time |
07:56 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-05-22 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2004-05-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | A) COMMENTS FROM PREVIOUS REVIEW HAVE | | | NOT BEEN ADDRESS. COMMENT NUMBER SHALL | | | REMAIN THE SAME TO AVOID CONFUSION. | | | 3) SHT A-3 SPECIFICATION WORK SHEETS RE- | | | FERED TO BY DBPR STAMP (3) SHALL BE SUB- | | | MITTED. 1 COPY WITH EACH SET OF PLANS. | | | SECTION 104.2.1. | | | 5) SHT A-3 S-13 GREASE INTECEPTOR NOT | | | APPROVED UNDER SINK.(ALSO SEE SHEET P-3) | | | ALSO PER RODNEY COMPO A SAMPLE POINT IS | | | REQUIRED ON SANITARY BLDG DRAIN PRIOR TO | | | DRAINING INTO TOILET ROOMS. (SEE ATTACH- | | | ED SHEET). SHOW LOCATION OF SAMPLE POINT | | | ON RISER DIAGRAM AND ON FLOOR PLAN. | | | WASTE ORD. #2938-96. | | | 7) SHT P-3 PLUMBING SPECIFICATIONS #7, | | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | | FROM REFERENCE. PDI-WH 201/SECTION 604.9 | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | *******NOTE: NO NOT REMOVE SHT A3 OF 8 | | | AS THIS SHEET HAS THE DBPR STAMP******** | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-24 |
Time |
18:32 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-03-24 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2004-03-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) PER TABLE 403.1 A DRINKING FOUNTAIN | | | IS REQUIRED. | | | 2) SHT A-2 ALL CAPPED AND DEMO'ED PLUMB- | | | ING LINES SHALL BE INSPECTED PRIOR TO | | | COVERING. | | | 3) SHT A-3 SPECIFICATION WORK SHEETS RE- | | | FERED TO BY DBPR STAMP (3) SHALL BE SUB- | | | MITTED. 1 COPY WITH EACH SET OF PLANS. | | | SECTION 104.2.1 | | | 4) SHTS A-3 & P-1 FIXTURE SCHEDULE, X5A | | | SHOWS QUANTITY 2, NONE FOUND. PLEASE | | | CLAIRFY. SECTION 104.2.1 | | | 5) SHT A-3 S-13 GREASE INTECEPTOR NOT | | | APPROVED UNDER SINK. CONTACT RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE, WASTE | | | ORD. 2938-96 @ (561) 837-4074 FOR GREASE | | | INTECEPTOR REQUIREMENTS. | | | 6) SHT P-2 WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. SECT- | | | ION 604.9 | | | 7) SHT P-3 PLUMBING SPECIFICATIONS #7, | | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | | FROM REFERENCE. PDI-WH 201/SECTION 604.9 | | | 8) AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THIS SPACE. INSTALLED | | | A MAXIMUM OF 4' ABOVE THE FLOOR FOR | | | SERVICING AND CERTIFICATION. SECTION | | | 608.13.2 | | | 9) SHT P-3 WATER HEATER DETAIL, THERMAL | | | EXPANSION CONTROL REQUIRED PER SECTION | | | 607.3.2 | | | 10) PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 - INITIALS ARE NOT ACCEPTABLE | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | THE SEAL SHALL BE PRESSED SO THAT IT CAN | | | BE READ. UNABLE TO READ NAME OF ENGINEER | | | AND TYPE OF PROFESSIONAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|