| Plan Review Stops For Permit 04031052 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-25 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-27 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-10 |
Time |
11:06 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2004-05-10 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2004-05-10 00:00:00 | NO BUILING REVIEW REQUIRED PER INFO | | | SUBMITTED AND PHONE CONVERSATION WITH | | | OWNER STEPHANIE AYLOR | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-05-08 |
Time |
12:43 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | DENIED BY STEFANO-WORK DONE EXCEEDS | | | DESCRIPTION OF WORK ON APPLICATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
kmcvey |
Date |
2004-03-18 |
Time |
15:13 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | PRE-INSPECT PER DEAN |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-21 |
Time |
11:28 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-25 |
Time |
15:35 |
Sent To |
B |
|
| Notes |
| 2004-05-25 00:00:00 | **** NOTES REDLINED **** | | | | | | 210.52E MISSING REAR RECEPT | | | 210.11C3 20A/#12 CIRCUIT FOR BATH. | | | | | | PLANS TO BLDG. FAILED PRE-INSPECT DUE | | | TO WORK AT HOUSE EXCEEDING WORK ON | | | APPLICATION. | | | SEE BLDG. PLAN REVIEW COMMENTS DUE | | | TO WALLS BEING OPENED UP COMPLETELY. | | | | | | NEW DRYWALL INSTALLED W/OUT INSPECTIONS | | | CALLED IN FOR ELECTRICAL AND PLUMB. | | | DRYWALL TO BE REMOVED AT ELECTRICAL | | | INSPECTORS DISCRETION. | | | | | | VALUE ON PERMIT TO BE INCREASED DUE TO | | | SCOPE OF WORK. | | | COMPLETE REWIRE, NEW PLUMB, AND BLDG | | | WORK. PER 104.6.5 FBC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
14:04 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-06 |
Time |
14:04 |
Sent To |
P |
|
| Notes |
| 2004-05-06 00:00:00 | ********* UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM THE FIRST | | | REVIEW. | | | PLEASE SUBMIT CLEAR AND COMPLETE PLANS/ | | | DRAWINGS FOR MIN REQUIRMENTS UNDER THE | | | 2002 NEC. | | | RISER/ PANEL SCHEDULE/ MIN CIRCUITS/ | | | AIC RATINGS ETC ETC. | | | | | | 2)NOTE: PLANS MUST HAVE A PRINTED NAME | | | AND A SIGNATURE OF THE PERSON RESPON- | | | -SIBLE FOR PLANS. 104.2.1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
09:00 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-15 |
Time |
18:45 |
Sent To |
P |
|
| Notes |
| 2004-04-15 00:00:00 | ********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT RISER DIAGRAM FOR | | | NEW SERVICE PER APPLICATION. | | | PLEASE PROVIDE ALL INFORMATION AS REQ'D | | | UNDER 215.5 NEC. | | | | | | 2)NOTE: PLEASE PROVIDE MIN INFORMATION | | | FOR ELECTRICAL PLAN SUBMITTED FOR NEC | | | CODE COMPLIANCE. | | | SD"S, RECEPTS,EGRESS LTS, PANEL SCHEDULE | | | ETC. | | | | | | 3)NOTE: PLANS MUST BE SIGNED BY PERSON | | | RESPONSIBLE FOR WORK. | | | 104.2.1 | | | SUBMIT TWO COPIES OF ALL PLANS. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-07 |
Time |
11:02 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | PRE-INSPECT PER DEAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-21 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-21 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
08:59 |
Sent To |
E |
|
| Notes |
| 2004-05-04 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-07 |
Time |
11:02 |
Sent To |
E |
|
| Notes |
| 2004-04-07 00:00:00 | TO BT DESK/PER LM | | 2004-04-06 00:00:00 | TO LM DESK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-22 |
Time |
16:20 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-04-22 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2004-04-22 00:00:00 | NO MECHANICAL WORK INDICATED ON PLAN OR | | | PERMIT APPLICATION.CONTRACTOR NOT | | | SIGNED ON BUILDING PERMIT APPLICATION. | | | ELECTRICAL & PLUMBING ONLY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-20 |
Time |
12:21 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | PER DEAN - PRE-INSPECT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-05-08 |
Time |
12:43 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-05-08 |
Time |
12:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
14:08 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-04-20 |
Time |
12:21 |
Sent To |
M |
|
| Notes |
| 2004-04-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) ALL INFORMATION, DRAWINGS ECT SHALL | | | BEAR THE NAME AND SIGNATURE OF THE PER- | | | SON RESPONSIBLE FOR THE DESIGN. SECTION | | | 104.2.1 | | | 2) KITCHEN SINK SHALL NOT DRAIN THROUGH | | | THE WET VENT FOR THE BATHROOM FIXTURES. | | | SECTION 909.1 - KITCHEN SINK SHALL DIS- | | | CHARGE DOWNSTREAM OF THE BATHROOM FIX- | | | TURES. | | | 3) TWO COPIES OF DRAWINGS REQUIRED PER | | | SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-15 |
Time |
19:06 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | PER DEAN - PRE-INSPECT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
kmcvey |
Date |
2004-03-18 |
Time |
15:14 |
Rev Time |
0.10 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | PER DEAN - PRE-INSPECT |
|
|