| Plan Review Stops For Permit 04031030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
10:33 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-05-06 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
05:40 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-04-28 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AND A COPY SUBMITTEDBEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2. SHOW DESIGN PRESSURES ON PAGE 1 OF | | | PLANS FOR THE WINDOWS/DOORS. | | | | | | 3. SHOW DOOR FROM GARAGE TO LAUNDRY IS | | | SOLID CORE OR INSULATED PER FBC. | | | | | | 4. SHOW ATTIC ACCESS ON PLANS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
10:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-13 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2004-05-13 00:00:00 | *** NOTES REDLINED *** | | | | | | 1)NOTE: PLEASE SEE MISSING SD LEADING | | | TO FLR ABOVE. NFPA-72 | | | | | | 2)NOTE: PLEASE SEE 210.52 FOR A COUPLE | | | OF RECEPTS MISSING. | | | | | | 3)NOTE: NO LOW VOLTAGE SHOWN ON PLANS, | | | WILL REQUIRE SEPARATE PLANS AND PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
10:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-06 |
Time |
05:36 |
Sent To |
B |
|
| Notes |
| 2004-05-06 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | | REVIEW. PLEASE SEE THAT THE SECOND FLR | | | ELECTRICAL PLAN WAS NOT SUBMITTED FOR | | | REVIEW. | | | PLEASE ALSO NOTE THERE IS NO ELECTRICAL | | | RISER DIAGRAM, PANEL SCHEDULE(S) ETC. | | | 215.5 | | | A COMPLETE REVIEW CAN NOT BE DONE AT | | | THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:12 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-04-01 |
Time |
10:23 |
Sent To |
M |
|
| Notes |
| 2004-04-01 00:00:00 | | | | DENIED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE SUBMIT A FULL SET OF PLANS FOR | | | REVIEW. THE SECOND FLOOR ELECTRICAL | | | PLAN, LOAD CALC'S, PANEL | | | SCHEDULE AND ELECTRICAL NOTES ARE | | | MISSING. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-12 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2004-05-12 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:12 |
Sent To |
E |
|
| Notes |
| 2004-05-04 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-25 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-19 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | TO SFD RACK/E | | 2004-03-19 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-01 |
Time |
10:35 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-05 |
Time |
11:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-05 |
Time |
11:47 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-04-12 |
Time |
17:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-25 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-25 |
Time |
11:03 |
Sent To |
I |
|
| Notes |
|
|