Plan Review Details - Permit 04030983
Plan Review Stops For Permit 04030983
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-07-21 Cont ID  
Sent By rmcdouga Date 2004-07-21 Time 15:12 Rev Time 1.00
Received By rmcdouga Date 2004-07-21 Time 15:12 Sent To  
Notes
2004-07-21 00:00:00RESTAMP PLANS TO SHOW STRUCTURE AS SHOWN
 ON SURVEY SUBMITTED WITH ORIGIONAL
 PERMIT APPLICATION, WHICH HAD REVERSE
 PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-20 Cont ID  
Sent By csiegber Date 2004-07-19 Time 14:49 Rev Time 2.00
Received By rmcdouga Date 2004-05-20 Time 10:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-28 Cont ID  
Sent By kstevens Date 2004-05-18 Time 12:06 Rev Time 2.00
Received By rmcdouga Date 2004-04-28 Time 09:42 Sent To  
Notes
2004-04-28 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE PLAN REVIEW NUMBER ON THE IMPACT
 FEE RECEIPT DOES NOT MATCH THE ONE THAT
 IS STAMPED ON THE PLANS. SUBMIT THE
 CORRECT RECEIPT.
  
 3) SPECIFY THE DESIGN PRESSURES FOR THE
 FRONT DOOR ON THE PLANS.
  
 4) THERE ARE TWO DIFFERENT SETS OF
 DESIGN PRESSURES LISTED FOR EACH OF THE
 TWO WINDOW OPENINGS ON EACH SIDE OF THE
 FRONT DOOR. THESE SHOULD ONLY HAVE ONE
 SET OF PRESSURES FOR EACH OPENING.
 PLEASE CORRECT.
  
 5) THERE IS A SET OF PRESSURES LISTED
 BELOW THE FRONT ELEVATION ON SHEET 1.
 PLEASE CORRECT.
  
 6) SPECIFY ON THE PLANS THAT THE WELDED
 WIRE MESH IN THE SLAB IS TO BE SUPPORTED
 ON APPROVED SUPPORTS AT NO MORE THAN 3'
 O.C. PER FBC 1909.3.
  
 7) REVISE THE HIGH RIB LATH NOTE ON
 SHEET 3 TO REQUIRE FASTENING AT EVERY
 RIB (4"OC) AS REQUIRED BY ASTM C 1063.
  
 8) SPECIFY ON THE PLANS THAT THE DOOR
 FROM THE GARAGE TO THE CONDITIONED SPACE
 IS REQUIRED TO BE SOLID CORE OR
 INSULATED AS REQUIRED BY FBC 13-603.
  
 9) THERE IS A LINE THROUGH THE ROOF
 NOTES AND CONNECTOR SCHEDULE ON SHEET 5.
 ARE THESE TABLES STRICKEN FROM THE PLANS
 PLEASE CLARIFY AND CORRECT.
  
 10) SUBMIT STATE PRODUCT APPROVAL FOR
 THE SINGLE OUTSWING ENTRY DOOR WITH
 SIDELITES.
  
 11) SUBMIT STATE PRODUCT APPROVAL WITH
 APPROVED STATUS FOR THE COLLIER GARAGE
 DOOR.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By btrobaug Date 2004-04-01 Time 08:48 Rev Time 0.50
Received By btrobaug Date 2004-04-01 Time 08:09 Sent To M
Notes
2004-04-01 00:00:00 
 PROVISO
 ~~~~~~~
 SUBMIT A REVISION PRIOR TO ROUGH
 ELECTRICAL INSPECTION INDICATING
 COMPLIANCE WITH THE FOLLOWING:
  
 1} ADDED RECEPTACLE IN BEDROOM #3 & #2
 AT THE ENTRANCE ON THE CLOSET SIDE TO
 COMPLY WITH 210.52(A).
  
 2} PLEASE SEE NFPA-72 (1999 ED.)
 8-1.4.2, REGARDING DETECTOR PLACEMENT.
  
 3} SEE NOTE #1 WITH REFERENCE TO THE
 1999 NEC, THE CITY OF WEST PALM BEACH
 HAS ADOPTED THE 2002 NEC. PLEASE CHANGE
 NOTE TO INDICATE SAME
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-07-19 Time 14:49 Rev Time 0.00
Received By csiegber Date 2004-07-19 Time 14:49 Sent To B
Notes
2004-07-19 00:00:00TO RM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-07 Cont ID  
Sent By csiegber Date 2004-05-07 Time 12:08 Rev Time 0.00
Received By csiegber Date 2004-05-07 Time 12:08 Sent To P
Notes
2004-05-07 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-07 Cont ID  
Sent By csiegber Date 2004-05-07 Time 12:08 Rev Time 0.00
Received By csiegber Date 2004-05-07 Time 12:07 Sent To P
Notes
2004-05-07 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-28 Cont ID  
Sent By mmclean Date 2004-03-18 Time 13:10 Rev Time 0.00
Received By rmcdouga Date 2004-03-17 Time 14:55 Sent To  
Notes
2004-03-19 00:00:00TO SFD RACK/E
2004-03-17 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-05 Cont ID  
Sent By btrobaug Date 2004-04-01 Time 08:49 Rev Time 0.30
Received By pkrauss Date 2004-04-05 Time 11:13 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-18 Cont ID  
Sent By kstevens Date 2004-05-15 Time 19:09 Rev Time 1.50
Received By kstevens Date 2004-05-15 Time 19:09 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-04-12 Cont ID  
Sent By csiegber Date 2004-05-07 Time 12:08 Rev Time 0.33
Received By jleech Date 2004-04-12 Time 16:50 Sent To B
Notes
2004-04-12 00:00:00RISER DIAGRAM DOES NOT MATCH FLOOR PLAN.
 FLOOR PLAN IS GARAGE RIGHT RISER DIAGRAM
 IS GARAGE LEFT.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By mmclean Date 2004-03-18 Time 13:10 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 13:10 Sent To I
Notes
***NONE***