Plan Review Details - Permit 04030977
Plan Review Stops For Permit 04030977
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-04 Cont ID  
Sent By rmcdouga Date 2004-05-04 Time 17:13 Rev Time 0.00
Received By rmcdouga Date 2004-05-04 Time 17:13 Sent To  
Notes
2004-05-04 00:00:00BUILDING PROVISO
  
 1) INSTALLED BUTT GLASS WINDOW IS TO BE
 INSPECTED BY THE ENGINEER. A SIGNED &
 SEALED LETTER APPROVING INSTALLATION IS
 TO BE SUBMITTED BEFORE C.O. IS ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-27 Cont ID  
Sent By csiegber Date 2004-05-03 Time 14:28 Rev Time 2.00
Received By rmcdouga Date 2004-04-22 Time 14:15 Sent To  
Notes
2004-04-22 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE TOTAL SQUARE FEET OF A/C AREA ON
 THE PLANS IS INCORRECT ON SHEET 3. IT
 SHOULD BE 3410 SQFT.
  
 3) SPECIFY THE ATTIC LIVE LOAD ON THE
 PLANS. SEE FBC TABLE 1604.1.
  
 4) FOR CLARITY, PLEASE INDICATE WHICH
 CONNECTORS ARE FOR THE FLOOR TRUSSES ON
 THE TRUSS TIE DOWN LAYOUT ON SHEET 9.
  
 5) SUBMIT STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR WITH APPROVED STATUS
  
 6) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR THE 8'X7' GARAGE DOOR.
  
 7) THE TRUSS ANCHOR SCHEDULE ON SHEET 9
 LISTS A NUE-VUE 48 CONNECTOR. THE STATE
 PRODUCT APPROVAL SUBMITTED IS FOR A
 NVRT 48 OR NVSTA 22. PLEASE CLARIFY.
  
 8) THE TRUSS CONNECTOR SCHEDULE LIST A
 SIMPSON HUC 412 WITH 1505# OF UPLIFT.
 THE CATALOG LISTS 905# FOR A HU412.
 SHOULD THIS BE A HUC 410,WHICH HAS A
 1505# UPLIFT.
  
 9) THE SUBMITTAL FOR THE BUTT GLASS
 WINDOW IS INCOMPLETE & CONTAINS ERRORS.
 THE QUAILITY ASSURANCE IS REQUIRED. THE
 LOT NUMBER IS INCORRECT. SPECIFY THE
 DESIGN PRESSURES AND LIMITATIONS. SUBMIT
 THE CALCULATIONS. SUBMIT THE SPECS. FOR
 THE GE SILICONE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By btrobaug Date 2004-04-01 Time 08:08 Rev Time 0.50
Received By btrobaug Date 2004-04-01 Time 07:54 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 14:28 Rev Time 0.00
Received By csiegber Date 2004-05-03 Time 14:28 Sent To B
Notes
2004-05-03 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-22 Cont ID  
Sent By mmclean Date 2004-03-18 Time 13:14 Rev Time 0.00
Received By rmcdouga Date 2004-03-17 Time 14:56 Sent To  
Notes
2004-03-19 00:00:00TO SFD RACK/E
2004-03-17 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-05 Cont ID  
Sent By btrobaug Date 2004-04-01 Time 08:09 Rev Time 0.30
Received By pkrauss Date 2004-04-05 Time 10:32 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-04-12 Cont ID  
Sent By pkrauss Date 2004-04-05 Time 10:53 Rev Time 0.33
Received By jleech Date 2004-04-12 Time 17:04 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By mmclean Date 2004-03-18 Time 13:14 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 13:14 Sent To I
Notes
***NONE***