| Plan Review Stops For Permit 04030910 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-11 |
Time |
15:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-11 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-04-06 |
Time |
15:40 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-04-06 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2005-04-06 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST, ITEM #1. | | | PROVIDE THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT, FS481, FAC61G1-16. | | | | | | 2.)THE OWNER ON THE APPLICATION | | | DOESN'T MATCH OUR RECORDS.PLEASE | | | PROVIDE A COPY OF THE DEED.THE NOC IS | | | LACKING COMPLETE INFORMATION (LEGAL, | | | OWNER ADDRESS) AND NEEDS TO BE RECORDED. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #4. | | | PROVIDE A DETAIL FOR THE SPIRAL STAIR. | | | FBC104.2.1, "SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL | | | NOT BE CITED AS A WHOLE OR IN PART . . . | | | AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION."THE DETAIL SHOULD INCLUDE | | | DIRECTION, ALL DIMENSIONS, HANDRAIL | | | INFORMATION TO SHOW COMPLIANCE WITH FBC | | | 1007.8.2.1. | | | | | | 4.)SOME COMMENTS WERE ADDRESSED IN THE | | | FORM OF A LETTER.THE PLANS SHOULD SHOW | | | CODE COMPLIANCE.PLEASE INCORPORATE | | | THESE COMMENTS AS A PART OF THE PLAN. | | | | | | 5.)DECLARE THE BUILDING TYPE ON THE | | | PLAN.THE TRANSMITTAL LETTER STATED | | | THAT IT IS TYPE IV UNPROTECTED.TYPE IV | | | CONSTRUCTION DOES NOT ALLOW COMBUSTIBLES | | | FOR FLOOR OR BEARING WALLS, FBC606 AND | | | FBC TABLE 600.THE 1 HOUR REQUIREMENT | | | YOU REFER TO IS IN YOUR MEMO IS FOR TYPE | | | IV 1 HR PROTECTED.COMBUSTIBLES ARE | | | STILL NOT ALLOWED IN TYPE IV 1 HR | | | PROTECTED. | | | | | | 6.)THE TRANSMITTAL LETTER INDICATED | | | THAT THE OCCUPANT LOAD WILL BE LESS THAN | | | 5 AND NOT OPEN TO THE PUBLIC, EXEMPTING | | | THIS JOB FROM VERTICAL ACCESSIBILITY. | | | PLEASE INDICATE THIS ON THE PLAN. | | | | | | 7.)PLEASE SEE PRIOR REQUEST FOR | | | EXITING INFORMATION.IT IS NOT CLEAR | | | WHERE THE DOORS LABELLED "1" (A DOUBLE | | | DOOR AT THE BASE OF THE STAIRS, A SINGLE | | | DOOR NEXT TO THE SPIRAL STAIR) LEAD.DO | | | THEY LEAD TO THE OUTSIDE OR TO OTHER | | | INTERIOR SPACE?PLEASE EITHER PROVIDE A | | | SITE PLAN OR MAKE A NOTE ON THE PLAN. | | | | | | 8.)SEE PREVIOUS LIST, SECOND FLOOR | | | BATHROOM TO BE ADAPTABLE, | | | FBC11-4.1.3(11).THE EXCEPTION FOR | | | VERTICAL ACCESSIBILITY DOES NOT WAIVE | | | THE REQUIREMENT FOR ADAPTABILITY | | | (ABILITY FOR FUTURE GRAB BARS IF | | | NECESSARY) IN THE BATHROOM. | | | | | | 9.)PLEASE PROVIDE DETAILS FOR THE | | | EXISTING ACCESSIBLE BATHROOM FBC11-4.22 | | | SO THAT EXISTING CONDITIONS CAN BE | | | REVIEWED FOR CODE COMPLIANCE. | | | | | | 10.) THE DESIGN CRITERIA PROVIDED SHEET | | | A1 GENERAL NOTES #21 IS FOR HANDRAILS. | | | PLEASE SEE FBC1608.2.2(1)THROUGH(4). | | | | | | 11.) HANDRAILS ARE TO EXTEND AT THE TOP | | | AND BOTTOM FBC1007.5.5. | | | | | | 12.) SHOW COMPLIANCE WITH FBC1015.3 FOR | | | THE OPENINGS ON THE STAIRRAIL. | | | | | | 13.)SHEET S1 DOES NOT HAVE ALL OF THE | | | INFORMATION REQUIRED FOR THE TITLE | | | BLOCK, FAC61G1-15. | | | | | | 14.)SHEET FP1 IS NOW MISSING FROM THE | | | PLAN.SEE MINIMUM PLAN REVIEW CRITERIA | | | FBC104.3.1.1(5). | | | | | | 15.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-31 |
Time |
08:12 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-01-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE PROVIDE A LEGIBLE SEAL AND | | | THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT, FS481, FAC61G1-16. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 3.)PROVIDE AREA CALCULATIONS | | | (PROPOSED | | | NEW 2ND FLOOR). | | | | | | 3.)THE OWNER ON THE APPLICATION | | | DOESN'T MATCH OUR RECORDS. | | | | | | 4.)PROVIDE A DETAIL FOR THE SPIRAL | | | STAIRS TO COMPLY WITH FBC1007.8.2.1. | | | | | | 5.)DECLARE A BUILDING TYPE FOR THE | | | EXISTING BUILDING, FBC CHAPTER 6; SHOW | | | COMPLIANCE WITH FBC TABLE 500.NOTE | | | THAT YOU ARE ADDING A STORY AS THE | | | MEZZANINE DOES NOT COMPLY WITH | | | FBC503.2.3.2 & 3. | | | | | | 7.)PROVIDE EXITING (EGRESS) | | | INFORMATION, FBC CHAPTER 10. NONE | | | SHOWN, | | | AND IT IS NOT CLEAR WHERE THE EXISTING | | | DOORS LEAD TO. | | | | | | 8.)FP1 DOES NOT SHOW SPRINKLERS ON | | | THE | | | SECOND FLOOR PLAN AND THE GROUND FLOOR | | | PLAN (FP1). | | | | | | 9.)ENERGY CALCS REQUIRED, | | | FBC13-103.1.2. | | | | | | 10.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 11.) DECLARE AN OCCUPANT LOAD FOR THE | | | MEZZANINE. | | | | | | 12.) HOW IS VERTICAL ACCESSIBILITY | | | ADDRESSED?FBC11-4.1.3(5) | | | | | | 13.) SECOND FLOOR BATHROOM TO BE | | | ADAPTABLE, FBC11-4.1.3(11). | | | | | | 14.) FIRST FLOOR BATHROOM TO BE | | | COMPLIANT WITH FBC11-4.22, PROVIDE | | | DETAILS. | | | | | | 15.) THE STAIRRAIL (A2) SERVES AS A | | | GUARDRAIL.GUARDRAILS ARE TO COMPLY | | | WITH FBC1608.2.2(1) THROUGH (4). | | | | | | 16.) THE HALL SINK/CABINET IS TO COMPLY | | | WITH FBC11-4.24.PROVIDE A DETAIL. | | | | | | 17.) THE TWO DOORS, 5 AND 1 ARE TO | | | COMPLY WITH CHAPTER 11, FIGURE 26, TWO | | | HINGED DOORS IN A SERIES. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-21 |
Time |
08:40 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-11-21 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-12 |
Time |
12:39 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-07-12 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-31 |
Time |
13:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-31 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | ******** UNSAT 2ND REVIEW ******** | | | | | | | | | 1)NOTE: PLEASE SEE NOTES #1&3 FROM | | | PREVIOUS REVIEW. | | | NO CHANGES WERE MADE FOR THESE COMMENTS. | | | | | | FS 471.023,481.219, FAC 61G15-23.002, | | | FAC 61G1-16. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-24 |
Time |
20:31 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-24 |
Time |
20:24 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED ON TITLE BLOCKS | | | FOR ARCH FIRM AND ENGINEERING FIRM. | | | PLEASE SEE FAC 61G1-16.004 (ARCH FIRM) | | | AND 61G15-23.002 FOR ENG'S. PLEASE ALSO | | | SEE FS 481.219 (ARCH'S) FS 471.023 FOR | | | ENG'S. | | | PLEASE SEE MISSING CERTICATE OF | | | AUTHORIZATION #. | | | PLEASE SEE THIS INFORMATION IS REQUIRED | | | ON ALL SHEETS AND FOR ALL TITLE BLOCKS | | | WEATHER OR NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | 2)NOTE: PLEASE SEE FP SHEET IS NOT | | | SIGNED, DATED AND SEALED. FS 481.221 | | | | | | 3)NOTE: PLEASE SEE NOTE ON ELECTRICAL | | | PLANS MENTIONS TO CONN ALL EM/EXT LTS | | | TO LIGHTING CIRCUIT, YET NONE OF THESE | | | FIXTURES COULD BE LOCATED ON PLANS? | | | PLEASE SEE POSSIBLE FIRE REVIEW | | | COMMENTS | | | FOR THIS. | | | | | | PLEASE SEE POSSIBLE NOTES FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE ONLY. | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-13 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-13 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | ******APPROVED****** | | | | | | PLEASE ENSURE THAT EMERGENCY LIGHTING | | | EQUIPMENT IS ADEQUATE TO ENSURE PROPER | | | LIGHTING REQUIREMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-07 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-07 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2005-04-07 00:00:00 | 1) HARD WIRED EMERGENCY LIGHTS WITH | | | BATTERY BACK UP ARE REQUIRED ON SECOND | | | FLOOR WHERE ARTIFICIAL LIGHTING IS NOT | | | ADEQUATE. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-27 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2005-01-27 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3. PLEASE PROVIDE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAILS | | | AND GUARDRAILS. | | | | | | 4. SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER | | | REMODEL. | | | | | | 5. ANY FIRE ALARM EQUIPMENT PLANNED | | | FOR THE PROPOSED SECOND FLOOR. | | | | | | 6. NO EMERGENCY LIGHTING ILLUSTRATED | | | ON SECOND FLOOR. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | TO "BOB"#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | TO "COMM" BD#13 | | 2005-07-06 00:00:00 | WAITING FOR SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-29 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-29 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2005-03-29 00:00:00 | TO "COMM" BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-21 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-17 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | TO COMM BD#17/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-16 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-16 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-12-07 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-11-21 |
Time |
18:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-15 |
Time |
07:38 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-07-15 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-04-26 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2005-04-26 00:00:00 | PLAN DENIED | | | 1) REFER TO SECTION 601.4 BALANCED | | | RETURN AIR FBC(M). | | | 2) PLEASE SHOW TYPE OF FIRE PROTUCTION | | | THROUGH THE FLOOR WITH THE 12X8 DUCT | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-07 |
Time |
14:18 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-02-07 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | DENIED: | | | 1.PLAN SHEET A-1 INDICATES THE | | | FOLLOWING PARTITIONS ARE FIRE RATED; #3 | | | (1ST FLOOR CONFERENCE ROOM) & #5 OFFICE, | | | #4.FIRE DAMPERS ARE NOT INDICATED ON | | | THE MECHANICAL PLANS.PER 2001 FBC(M) | | | 607.6, LOCATION AND INSTALLATION DETAILS | | | FOR EACH FIRE DAMPER AND ACCESS DOOR | | | SHALL BE PROPERLY IDENTIFIED ON PLAN. | | | | | | 2.PLAN SHEET A3 INDICATES UL L501 | | | FLOOR/CEILING ASSEMBLY WITH A 1 HOUR | | | RATING.PLEASE CLARIFY PROTECTION OF | | | OPENINGS. | | | | | | 3.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS IN ACCORDANCW WITH 2001 | | | FBC(M) TABLE 403.3. | | | | | | 4.PROVIDE ENERGY CALCULATIONS PER | | | CHAPTER 13 FBC SUB-CHAPTER 4. | | | | | | 5.SEE COMMONTS BY ELECTRICAL & BUILING | | | FOR REQUIRE REQUIREMENTS FOR LICENSE | | | NUMBERS AND CERTIFICATE OF AUTNORIZATION | | | PER FS 481.219 & 471.023. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-15 |
Time |
15:35 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-07-15 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | PASSED/PROVISO | | | | | | | | | A DRINKING FOUNTAIN IS REQUIRED. TABLE | | | 403.1 - ALSO SEE SECTION 410.1 - | | | REVISION REQUIREDKSTEVENS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-23 |
Time |
15:47 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-04-23 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2005-04-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | 2) ALL ARCHITECTURAL SHEETS, THE TITLE | | | BLOCK MUST, AT A MINIMUM, CONTAIN THE | | | FOLLOWING INFORMATION: | | | PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT. 61G1-16.004(6) | | | 5) THS A1 DETAIL #2 SINK SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. RESPONSE NOTED BUT THE | | | FOLLOWING INFORMATION IS STILL REQUIRED: | | | A. KNEE CLEARANCE 11-4.24.3 | | | B. SINK DEPTH 11-4.24.4 | | | C. CLEAR FLOOR SPACE 11-4.24.5 FORWARD | | | APPROACH REQUIRED. | | | D. EXPOSED PIPES & SURFACES 11-4.24.6 | | | E. FAUCETS 11-4.24.7 | | | 6) SHT A1 DETAIL #3 TOILET ROOM SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.16, | | | 11-4.19, & 11-4.22 AND ALL SUBSECTIONS. | | | RESPONSE NOTED, BUT SECTION 11-4.1.3(5) | | | ITEM 3 REFERS TO VERTICAL ACCESSIBILITY | | | AND THESE ARE EXCEPTIONS FOR VERTICAL | | | ACCESSIBLITY ONLY. | | | 7) SHT A2 WHITE OUT AND HAND DRAWN | | | CHANGES TO SIGNED/SEALED PLANS ARE NOT | | | APPROVED. NEW SHEETS WITH CHANGES ARE | | | REQUIRED. SECTION 104.2.1.3. | | | ****************NEW COMMENT************* | | | 1B) INDEX OF DRAWINGS INDICATES SHEET | | | FP-1 FIRE PROTECTION PLANS, BUT THIS | | | SHEET IS NOT IN THE SETS OF PLANS. | | | PLEASE CLARIFY. SECTION 104.2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-14 |
Time |
15:08 |
Rev Time |
1.30 |
| Received By |
kstevens |
Date |
2005-02-14 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHTS A0, A1, A2, S1 UNABLE TO READ | | | THE INFORMATION FROM THE SEAL. RESEAL | | | THE SHEETS TO IMPRESS THE INFORMATION ON | | | THE SEALED SHEETS. FAC 61G1-16.001/.002 | | | AND FS 481.2055. | | | 2) ALL ARCHITECTURAL SHEETS, THE TITLE | | | BLOCK MUST, AT A MINIMUM, CONTAIN THE | | | FOLLOWING INFORMATION: | | | 61G1-16.004(2) FIRM LICENSE NUMBER | | | 61G1-16.004(6) PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT. | | | FS 481.219 & 481.2055. | | | 3) SHT FP-1 SHEET NOT SIGNED, SEALED, | | | AND DATED. 61G1-16.003 & FS 481.2055. | | | 4) SHT A1 DETAIL #1NO DEAD ENDS, | | | SECTION 704.5. ALL DEMO'D PIPING SHALL | | | NOT BE COVERED PRIOR TO INSPECTION. | | | 5) SHT A1 DETAIL #2 SINK SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. (FORWARD APPROACH REQUIRED) | | | 6) SHT A1 DETAIL #3 TOILET ROOM SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.16, | | | 11-4.19, & 11-4.22 AND ALL SUBSECTIONS. | | | 7) SHT A2 ROOM FINISH. INDICATE WHAT | | | "WD" IS FOR THE BASE AND SHOW COMPLIANCE | | | WITH SECTION 1204.2 SURRONDING MATERIALS | | | FOR THE BASE AND THE PAINTED WALLS. | | | 8) SHT P-1 CLEANOUT IS REQUIRED AT THE | | | JUNCTION OF THE BUILDING DRAIN AND THE | | | BUILDING SEWER FOR THE NEW BUILDING | | | DRAIN LINE FOR THE SINK AND THE 2ND | | | FLOOR TOILET ROOM. SECTION 708.3.5. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-18 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-18 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2005-02-18 00:00:00 | APPROVED BY GRACE JOYCE, PLANNER | | | 822-1447, MINOR AMENDMENT.CALLED & | | | LEFT MSG ON ED Z VOICE MAIL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-25 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-25 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | DENIED, NEED TO APPLY FOR A MINOR | | | AMENDMENT ON THE 5TH FLOOR.PER DAVID | | | KANNING, PLANNER 659-8031.CALLED | | | CONTR FOR PICK UP FILE H MM |
|
|