Plan Review Details - Permit 04030755
Plan Review Stops For Permit 04030755
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-08-27 Cont ID  
Sent By jgomez Date 2004-08-27 Time 16:56 Rev Time 0.25
Received By jgomez Date 2004-08-27 Time 16:56 Sent To PC
Notes
2004-08-27 00:00:00ENGINEER'S LETTER TO CLARIFY ITEMS ON
 PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-08-11 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:43 Rev Time 0.33
Received By jgomez Date 2004-08-11 Time 16:23 Sent To PC
Notes
2004-08-11 00:00:00CHECKLIST:
 1-PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 4-9-04:
 A)DETAIL E/4 AND RESIDENTIAL NOTES ON
 SHEET #2 TO MATCH.
 B)DETAIL A/4: SPECIFY WHERE ARE TABLES
 6 AND 8 TAKEN FROM?. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 2-FLOOD ZONE REVISION AND GARAGE DOOR
 PRODUCT APPROVAL ARE OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-09 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:32 Rev Time 1.00
Received By jgomez Date 2004-04-09 Time 12:07 Sent To PC
Notes
2004-04-09 00:00:00BUILDING REVIEW PROVISO:
 1-FLOOD ZONE AO: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DRAWING #2 DON'T MATCH. REVISE AS
 REQUIRED. CLARIFY FASTENER SPACING.
 3-TYPICAL WALL SECTION A/4: SPECIFY
 WHERE ARE TABLES 6 AND 8 FOR ROOF
 FASTENERS TAKEN FROM.SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-06 Cont ID  
Sent By jleech Date 2004-03-31 Time 19:36 Rev Time 2.00
Received By jgomez Date 2004-04-05 Time 17:44 Sent To  
Notes
2004-04-05 00:00:00BUILDING REVIEW CHECKLIST:
 1-REVISE ENERGY CALCULATIONS. NEED WORST
 CASE SCENARIO IF SAME CALCS WILL BE
 USED FOR ALL HOUSES. OR PROVIDE ENERGY
 CALCS THAT ARE CALCULATED FOR EACH
 HOUSE ACCORDING TO THE ORIENTATION.
 2-PROVIDE FLORIDA PRODUCT APPROVAL AND
 DRAWINGS FOR ENTRY DOOR THAT MATCH.
 "BENCHMARK" AND THERMA TRU DOORS ARE
 2 DIFFERENT MODELS.
 3-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE FOR SLIDING GLASS DOORS AND FIXED
 WINDOWS AND PROVIDE ONLY THE DRAWINGS
 FOR DOORS/WINDOWS THAT ARE GOING TO BE
 INSTALLED IN THIS HOUSE.
 4-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. CLARIFY SPACING
 OF FASTENER.
 5-TYPICAL WALL SECTION A/4. SPECIFY
 WHERE ARE TABLES 6 AND 8 FOR ROOF TILE
 FASTENING TAKEN FROM. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 6-NEED RECORDED NOTICE OF COMMENCEMENT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-29 Cont ID  
Sent By hmoser Date 2004-03-24 Time 17:10 Rev Time 0.45
Received By jleahy Date 2004-03-29 Time 14:58 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:43 Rev Time 0.00
Received By csiegber Date 2004-08-17 Time 12:43 Sent To B
Notes
2004-08-17 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:32 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 14:32 Sent To B
Notes
2004-07-29 00:00:00TO JG DESK/NEW PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-21 Cont ID  
Sent By csiegber Date 2004-05-21 Time 09:19 Rev Time 0.00
Received By csiegber Date 2004-05-21 Time 09:19 Sent To Z
Notes
2004-05-21 00:00:00REVISION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-06 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:21 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 14:15 Sent To  
Notes
2004-04-06 00:00:00PLANS ON JULIO'S DESK. WAITING FOR
 CLARIFICATION ON IMPACT FEES. STAMPED
 PAID AMOUNT AND PAID RECEIPT DON'T MATCH
 .
2004-03-19 00:00:00TO SFD RACK/E
2004-03-16 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-24 Cont ID  
Sent By jleahy Date 2004-03-29 Time 14:58 Rev Time 0.25
Received By hmoser Date 2004-03-24 Time 17:08 Sent To E
Notes
2004-03-24 00:00:00PASS/PRIVISO
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-31 Cont ID  
Sent By jgomez Date 2004-04-06 Time 16:51 Rev Time 0.25
Received By jleech Date 2004-03-31 Time 19:35 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By csiegber Date 2004-05-21 Time 09:19 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 12:21 Sent To I
Notes
***NONE***