Plan Review Details - Permit 04030575
Plan Review Stops For Permit 04030575
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-06 Cont ID  
Sent By rmcdouga Date 2004-05-06 Time 10:11 Rev Time 0.00
Received By rmcdouga Date 2004-05-06 Time 10:11 Sent To  
Notes
2004-05-06 00:00:00SUBMITTAL FOR COLLIER GARAGE DOOR IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-05 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2004-05-03 Time 11:49 Sent To  
Notes
2004-05-03 00:00:00BUILDING PROVISO
  
 1) SUBMIT A SIGNED AND SEALED REPORT
 FROM THE ENGINEER APPROVING THE BUTT
 GLASS INSTALLATION BEFORE THE C.O. IS
 ISSUED.
  
 2) SUBMIT STATE PRODUCT APPROVAL WITH
 APPROVED STATUS FOR THE COLLIER GARAGE
 DOOR AND FOR THE 8'X 7' GARAGE DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-14 Cont ID  
Sent By kstevens Date 2004-04-22 Time 16:47 Rev Time 0.00
Received By rmcdouga Date 2004-05-03 Time 11:48 Sent To  
Notes
2004-04-14 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE FL PRODUCT APPROVAL #S LISTED FOR
 TWO OF THE FIXED GLASS WINDOWS IN THE
 SCHEDULE ON SHEET 3 ARE INCORRECT.
  
 3) SPECIFY THE CONNECTORS AT THE BASE OF
 THE TWO 3-2X4 POSTS IN THE WALL BELOW
 THE GIRDER TRUSS AT MASTER SUITE.
  
 4) SPECIFY THE ATTIC LIVE LOAD ON THE
 PLANS. SEE FBC TABLE 1604.1.
  
 5) SUBMIT STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR WITH APPROVED STATUS
 AND FOR THE 8'X 7' GARAGE DOOR WHICH IS
 SMALLER THAN THE MINIMUM SIZE ALLOWED BY
 THE PROD.APP. DRAWING.
  
 6) THE TRUSS ANCHOR SCHEDULE ON SHEET 9
 LISTS A NUE-VUE NVSTA 48 CONNECTOR. THE
 STATE PRODUCT APPROVAL SUBMITTED LISTS A
 NVRT 48 OR NVSTA 22. PLEASE CLARIFY.
  
 7) THE TRUSS CONNECTOR SCHEDULE LISTS A
 SIMPSON HUC 412 CONNECTOR WITH 1505# OF
 UPLIFT. THE STATE PRODUCT APPROVAL IS
 FOR A HU 412 WITH 905# OF UPLIFT. PLEASE
 CLARIFY.
  
 8) THE STORM PANEL INSTALLATION SCHEDULE
 AND KEY PLAN IS MISSING THE WINDOW IN
 BATH #2. PLEASE CORRECT.
  
 9) THE SUBMITTAL FOR THE BUTT GLASS
 WINDOW IS INCOMPLETE AND HAS ERRORS. THE
 THIRD PARTY QUALITY ASSURANCE IS
 REQUIRED. SPECIFY THE DESIGN PRESSURES.
 LIST LIMITATIONS. SUBMIT CALCULATIONS.
 SUBMIT THE SPECIFICATIONS FOR THE GE
 1200 SILICONE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-23 Cont ID  
Sent By jleahy Date 2004-03-23 Time 14:19 Rev Time 0.45
Received By jleahy Date 2004-03-20 Time 14:19 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-05-05 Time 16:49 Rev Time 0.00
Received By csiegber Date 2004-05-05 Time 16:49 Sent To B
Notes
2004-05-05 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 12:19 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 12:19 Sent To P
Notes
2004-04-20 00:00:00TO KS BOX/JL REVIEWER/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-14 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:41 Rev Time 0.00
Received By rmcdouga Date 2004-03-11 Time 13:08 Sent To  
Notes
2004-03-16 00:00:00TO SFD RACK/E
2004-03-11 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-23 Cont ID  
Sent By jleahy Date 2004-03-23 Time 14:19 Rev Time 0.25
Received By hmoser Date 2004-03-23 Time 18:14 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-22 Cont ID  
Sent By kstevens Date 2004-04-22 Time 16:46 Rev Time 0.33
Received By kstevens Date 2004-04-22 Time 16:46 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By csiegber Date 2004-04-20 Time 12:19 Rev Time 0.33
Received By jleech Date 2004-03-31 Time 18:45 Sent To B
Notes
2004-03-31 00:00:00DENIED;
 RISER DIAGRAM DOESNOT MATCH FLOOR PLAN.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-12 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:41 Rev Time 0.00
Received By mmclean Date 2004-03-12 Time 15:41 Sent To I
Notes
***NONE***