| Plan Review Stops For Permit 04030554 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-20 |
Time |
09:01 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2005-03-20 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2005-03-20 00:00:00 | REVISIONS- |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-25 |
Time |
11:11 |
Rev Time |
2.25 |
| Received By |
jwitmer |
Date |
2004-06-25 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-26 |
Time |
15:11 |
Rev Time |
5.50 |
| Received By |
jwitmer |
Date |
2004-05-26 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2004-05-26 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04030554 | | | ADD: 2901 OKEECHOBEE BLVD | | | CONT: ROEPNACK | | | TEL: (561)444-2995 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) THIS BUILDING REQUIRES A SPECIAL | | | INSPECTOR, ALL SUBMITTALS,PLANS AND | | | "PRODUCT APPROVALS" REQUIRE (3) COPIES. | | | | | | 2) PROJECTS THAT HAVE A PERMIT APPLICA- | | | TION DATE AA OF OCT.1, 2003 REQUIRE | | | STATEWIDE APPROVAL, THE MIAMI DADE | | | REPORT SUBMITTED "RUSKIN MANUFACTURING" | | | FOR EXTERIOR LOUVERS HASN,T SUBMITTED | | | FOR THIS APPROVAL REQUIRING LOCAL PRO- | | | DUCT APPROVAL. THE LOCAL PRODUCT APPROV- | | | AL FORM IS ATTACHED TO THE NOA AND IS TO | | | BE FILLED OUT BY THE MANUFACTURER. | | | NOTE: | | | 3) THE VARIOUS MANUACTURED CANOPIES WILL | | | REQUIRE A SEPERATE PERMIT REVIEWS AND | | | ASSOCIATED FEES. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-15 |
Time |
07:40 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2004-04-15 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2004-04-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04030554 | | | ADD: 2901 OKEECHOBEE BLVD | | | CONT: ROEPNACK | | | TEL: (561)444-2995 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENTS FROM THE FOUNDATION PERMIT | | | (04030555) 1-8. | | | 2) PLANS INDICATE VARIOUS PRE-ENGINEERED | | | CANOPIES, PROVIDE INFORMATION ON THESE | | | CANOPIES TO BE CONSIDERED UNDER THIS | | | PERMIT. NOTE ON THE FOUNDATION PAGE , | | | FOUNDATION SUBJECT TO CHANGE PENDING THE | | | REVIEW. IF ENGINEER TO CHANGE CANOPY | | | FOUNDATION, WOULD IT NOT MAKE SENSE TO | | | HAVE THIS INFORMATION BEFORE HAND? | | | 3) PLANS INDICATE A CANOPY ENCLOSED BY | | | A FENCE. SHEET BA-1.2 INDICATES A | | | 300 GAL POLY TANK AND (6) 500 GAL TANKS. | | | WHAT TYPE OF LIQUIDS ARE TO BE HOUSED IN | | | THESE TANKS? IS THIS A HAZARDOUS OCCUPAN | | | CY? DOES THIS AREA REQUIRE A SECONDARY | | | CONTAINMENT? THIS AREA TO BE FIRE SPRINK | | | LERED? AGAIN NO PLANS SUBMITTED FOR | | | CANOPY OR AWNING? | | | 4) SHEET# S1.0 NOTE# 8, PRECAST COLUMNS | | | ARE TO BE FASTENED TO THE FOUNDATION? | | | HOW WILL THIS HAPPEN, THIS INFORMATION | | | WILL ALSO BE NEEDED FOR THE FOUNDATION | | | PERMIT. WILL THERE BE EMBEDS, ETC? | | | LOCATIONS? | | | 5) SHEET S1.1 DETAIL# 3, PLANS INDICATE | | | A BEAM AT THE C-1 COLUMN AND SPANING | | | INTO THE PRECAST COLUMNS, HOW WILL THIS | | | OCCUR? WILL THE CENTER OF THE PRECAST | | | COLUMN BE VOID FOR THIS BEAM? | | | 6) THIS SAME SHEET DOES NOT INFORMATION | | | AS TO WHAT TYPE OF BEAM TO BE USED AT | | | THE WINDOWS OF THE LOUNGE, SHOP FOREMANS | | | WINDOW, HALL OR OTHER OPENINGS IN THE | | | BLOCK WALLS?IN SOME CASES THESE OPENINGS | | | WILL ABUT AGAINST PRECAST COLUMNS? THE | | | EAST WALL WHERE THE LOUVER IS LOCATED | | | NO MENTION OF HOW TO HANDLE THIS, OR | | | HEIGHT OF OPENING? | | | 7) SHEET S.0 DETAIL# 7, HOW DOES THE | | | VERTICAL BARS ATTACH TO THE SPANDREL | | | BEAM? | | | 8) SHEET M-2 LOUVER EAST WALL WITHIN | | | 15'-0" OF THE PROPERTY LINE, REQUIRES | | | OPENING PROTECTIVES, 705.1.1.2. | | | 9) INDICATE HOW THE RTU ARE TO BE FASTEN | | | ED TO THE ROOF DECK? | | | 10)1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | | WITH AN IMPACT RESISTANT COVERING MEET- | | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST. | | | 11) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 12)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) SWING DOORS | | | C) OVERHEAD DOORS | | | D) EXTERIOR LOUVERS | | | E) ROOFING ASSEMBLIES | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-10 |
Time |
12:50 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-10 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | REVIEWED FOR ELECTRICAL, | | | FIRE TO REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-12 |
Time |
07:38 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-05-11 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2004-05-12 00:00:00 | STAMPED TWO ELEC SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-14 |
Time |
15:46 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2004-04-14 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2004-04-14 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SIGN PLANS WITH COMPLETE | | | SIGNATURE AS REQ'D UNDER FS 471.025, | | | FAC 61G15-23.002 | | | PLEASE ALSO INCLUDE ALL LICENSE #'S ON | | | TITLE BLOCK AS REQ'D UNDER FAC 61G15-23. | | | 002. FS 471.023 (CA#) DATE ALSO MUST BE | | | SIGNED AS ORIG. THESE ITEMS HAVE BEEN | | | SENT TO US FROM THE FBPE'S IN OTHER | | | CASES AND WILL EFFECT ALL PLANS. | | | | | | 2)NOTE: PLEASE INCLUDE EQUIPMENT GROUND- | | | ING CONDUCTORS FOR ALL PANELS.250.122, | | | 250.110,,, | | | | | | 3)NOTE: PLEASE SEE NOTE #1 E-6, MENTIONS | | | 4-3 1/2" CONDUITS, YET SB PANEL SHOWS | | | 4" CONDUITS, PLEASE CORRELATE. | | | | | | 4)NOTE: PLEASE LABEL AND IDENTIFY ALL | | | PANELS/EQUIPMENT ON PLANS. | | | PANELS SBF AND SBR. | | | PLEASE SEE NOTE:4 ON E-2, MENTION 80A | | | PANEL TO BE INSTALLED FOR TELE BOARD. | | | THIS COULD NOT BE LOCATED ON RISER DIA- | | | -GRAM OR ON A PANEL FEEDING THIS 80A | | | SUB-PANEL? | | | THERE IS A "PANEL TC" LOCATED ONPANEL- | | | -BOARD SB, BUT IS ONLY A 60A FEED. | | | IS THIS PANEL ANOTHER PANEL OR SAME? | | | PLEASE CORRELATE RISER, PANEL SCHEDULES, | | | SIZE ETC. | | | | | | 5)NOTE: PLEASE SEE ELECTRIC RISER KEY- | | | -NOTES, #3, MENTIONS BOTH SB, SBM TO BE | | | "MAIN LUGS ONLY". PLEASE ADJUST NOTE. | | | PLEASE ALSO CORRELATE AIC RATINGS INDI- | | | -CATED. SBM IS SHOWN AS 10,000. SB AND | | | NOTES MENTIONS, 22K. | | | | | | 6)NOTE: PLEASE SEE 700.12E FOR CIRCUIT-- | | | -ING OF EM/EXT LTS. TO BE ON WITH LOCAL | | | BRANCH CIRCUITS. | | | | | | 7)NOTE: PLEASE SEE THAT ALL CIRCUITING | | | WILL BE REQ'D TO BE ON PLANS AND CORRE- | | | -LATE WITH SUBMITTED PANEL SCHEDULE(S). | | | IF PERTAING TO ONLY GFI'S IN BAYS, | | | PLEASE CALL TO DICUSS A POSSIBLE NOTE/ | | | PROVISO. THIS MAY RESULT IN A FUTURE | | | REVISION AND FEES DUE AT THAT TIME. | | | IF THIS NOT AN OPTION, PLEASE ADDRESS | | | AS NOTED. | | | | | | 8)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | | ON ELECTRICAL PLANS. | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | AS THEY MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-03-08 |
Time |
14:47 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-03-08 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | PASSED: | | | | | | 1. REVISION AS SUBMITTED REVIEWED. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-08-12 |
Time |
10:31 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-08-12 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | PASSED: | | | 1. SEE PERMIT # 04060907 FOR UNDERGROUND | | | UTILITIES AND SITE WORK FOR THIS | | | ADDITION. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-15 |
Time |
09:49 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-15 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2004-04-15 00:00:00 | PASSED WITH PROVISOS: | | | 1. PLEASE CONTACT MR. RODNEY COMPO AT | | | 837-4051 EXT. 4074 FOR OIL / WATER | | | SEPARATOR REQUIREMENTS IN SEWER LINE | | | PRIOR TO CONNECTING TO CITY LINE. | | | 2. PLEASE INFORM FDOT AT 432-4966 AND | | | CITY ENGINEER' OFFICE AT 659-8040 PRIOR | | | TO ANY WORK WITHIN PUBLIC R.O.W. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-31 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-31 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | 1) ALL COMMENTS FROM THE ORIGINAL REVIEW | | | WERE INCLUDED WITH THE FIRE ALARM | | | DRAWINGS, 04090486 WHICH WERE PASSED BY | | | N MCCRAY ON 1/26/05. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-12-08 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-12-08 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2004-12-08 00:00:00 | 1) WHEN THE FIRE ALARM CONTROL UNIT, | | | INCLUDING THE DAILER-COMMUNICATOR, IS | | | REPLACED IN AN EXISTING SYSTEM, IT WILL | | | BE TREATED AS A NEW SYSTEM. | | | | | | 2) NEW FIRE ALARM SYSTEMS SHALL BE UL | | | LISTED FOR CENTRAL STATION SERVICE. | | | | | | 3) ALL NEW FIRE ALARM SYSTEMS THAT | | | SUPERVISE FIRE SPRINKLER SYSTEMS SHALL | | | BE UL CERTIFICATED AND HAVE DOCUMENTS | | | ATTESTING TO THIS CERTIFICATION PRIOR | | | TO | | | FINAL APPROVAL OF THE FIRE ALARM | | | SYSTEM. | | | | | | 4) THE FIRE ALARM SYSTEM SHALL BE CLASS | | | "A" OR FULLY ADDRESSSABLE. | | | | | | 5) THE WEST PALM BEACH FIRE MARSHAL | | | OFFICE REQUIRES SMOKE DUCT DETECTORS TO | | | SEND A GENERAL FIRE ALARM NOT A | | | SUPERVISORY. | | | | | | 6) PLEASE PROVIDE CUT SHEETS FOR ALL NEW | | | DEVICES AND EQUIPMENTS. | | | | | | 7) ALL THESE CHANGES SHOULD BE | | | SUBMITTED | | | UNDER PERMIT 04090486 (FIRE ALARM | | | PERMIT). | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-06-30 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-06-30 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-19 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-05-19 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | 1) ELECTRONIC SWITCHES, CHAINS AND LOCKS | | | WILL BE REQUIRED ON FIRE LINE BACKFLOW | | | DEVICE. | | | | | | 2) PLEASE DISPLAY EXIT ROUTE(S) FOR | | | VEHICLE LIFTS 1-6. | | | | | | 3) PLEASE INDICATE TESTING CRITERION | | | FOR CO VENTILATION SYSTEM. | | | | | | 4) THE NOTE ON PAGE M-4 INDICATES | | | SMOKE BOMBS WILL BE USED TO TEST | | | CARBON MONOXIDE SYSTEM. THESE NOTES | | | DO NOTINDICATE HOW THE MONITORS | | | THEMSELVES WILL BE TESTED. IT WOULD | | | APPEAR THAT CALIBRATION GAS SHOULD BE | | | USED TO ENSURE SET POINTS ON THE | | | DETECTORS ARE PROPER. PLEASE ADVISE. | | | | | | 5) WHY IS THE STORAGE YARD NOT FIRE | | | SPRINKLER PROTECTED. IS THERE NOT | | | MATERIALS STORED THERE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-12 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-12 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2004-03-12 00:00:00 | 1) PLEASE EXPLAIN ACCESS FOR NEW | | | SERVICE SHOP. VARIOUS GATES AND FENCES | | | ARE PRESENT ON THE SITE. | | | | | | 2) ELECTRONIC SWITCHES, CHAIN AND LOCK | | | REQUIRED ON FIRE LINE BACKFLOW DEVICE. | | | | | | 3) FIRE AND PARAMEDICAL ACCESS TO THE | | | SITE SHALL BE PROVIDED DURING | | | DEMOLITION AND CONSTRUCTION ACTIVITIES. | | | | | | 4) PLEASE PROVIDE MORE DETAILS ON | | | PROPOSED STORAGE. | | | | | | 5) PLEASE PROVIDE FURTHER DETAILS ON | | | 300 GAL POLY TANK. | | | | | | 6) WHAT OPENING PROTECTIVE DEVICE IS | | | PLANNED BETWEEN HALL 103 AND SERVICE | | | SHOP 112. | | | | | | 7) THERE APPEARS TO BE TOO MANY | | | TABLES AND CHAIRS SHOWN IN LOUNGE 111. | | | | | | 8) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 9) PLEASE EXPLAIN EXITING RATIONALE | | | FROM OTHER AREAS BESIDES SERVICE SHOP. | | | IT APPEARS THAT EXITING HAS TO ENTER | | | VIA THE SERVICE SHOP. | | | | | | 10) ADDITONAL EXIT SIGNS APPEAR TO BE | | | NEEDED. | | | | | | 11) ARE THERE ANY EMERGENCY LIGHTS | | | PRESENT. | | | | | | 12) ARE FIRE RESCUE VEHICLES EXPECTED | | | TO PASS UNDERNEATH THE NEW METAL | | | CANOPY. | | | | | | 13) BUILDING ADDRESS REQUIRED. A | | | MINIMUM OF 6" HIGH NUMBERS. | | | | | | 14) DOOR SCHEDULE INDICATES NO LABEL | | | DOORS. | | | | | | 15) MORE DETAILS REQUIRED ON CARBON | | | MONOXIDE EVACUATION SYSTEM THAT IS | | | PLANNED FOR USE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-08 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-08 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | TO "COMM" BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
P |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
14:00 |
Sent To |
ENG |
|
| Notes |
| 2005-01-14 00:00:00 | TO "ENG" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-22 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-22 |
Time |
11:46 |
Sent To |
FIRE |
|
| Notes |
| 2004-11-22 00:00:00 | SENT TO "FIRRE" BOX/RREVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
10:52 |
Sent To |
M |
|
| Notes |
| 2004-10-25 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
12:53 |
Sent To |
M |
|
| Notes |
| 2004-09-22 00:00:00 | TO PK DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-06 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-06 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | TO COMM BD#43/P&M |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-10 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-10 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | TO COMM BD#38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-10 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-10 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2004-05-10 00:00:00 | TO COMM BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2004-03-11 00:00:00 | TO COMM BD#2/TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-05 |
Time |
15:21 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-11-05 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
10:52 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-10-05 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2004-10-06 00:00:00 | PROVISO: | | | CO SENSORS SHALL ACTIVATE FANS UPON | | | DETECTION OF A CONSENTRATION RATE OF NOT | | | GREATER THAN 25 PPM PER 2001 FBC(M) | | | 403.3. | | | | | | CO SENSORS TO BE TESTED FOR FINAL | | | INSPECTION. | | | | | | PVC CONDENSTATE PIPE LOCATED ON THE | | | ROOF SHALL HAVE PROTECTION FROM UV RAYS | | | PER MANUFACTURER'S SPECIFICATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
12:53 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-07-16 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | PROVISO: | | | CO SENSORS SHALL ACTIVATE FANS UPON | | | DETECTION OF A CONSENTRATION RATE OF NOT | | | GREATER THAN 25 PPM PER 2001 FBC(M) | | | 403.3. | | | | | | CO SENORS TO BE TESTED FOR FINAL | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-28 |
Time |
09:00 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-05-28 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2004-05-28 00:00:00 | PROVISO: | | | 1. PROVIDE SUBMITTAL FOR TESTING OF THE | | | CO SENSORS.PLEASE REVISE PLANS AND | | | REMOVE COMMENT "CO SENSORS TO BE TESTED | | | BY SMOKE BOMBS".REFERENCE MANUFACTURER | | | INSTRUCTIONS FOR TESTING.CO SENSORS | | | SHALL ACTIVATE FANS UPON DETECTION OF | | | A CONSENTRATION RATE OF 25 PPM (MAXIMUM) | | | PER 2001 FBC(M) 403.4. | | | | | | 2. PROVIDE MANFACTURERS INSTALLATION | | | INSTRUCTIONS FOR THE CONNECTION OF THE | | | UNDERFLOOR EXHAUST SYSTEM TO THE 3" | | | MUFFLER HOSE. PROVIDE DETAIL ON JOBSITE | | | AT THE TIME OF INSPECTION. | | | | | | 3.PLEASE NOTE PLANS FOR THE UNDERFLOOR | | | EXHAUST ARE NOT SIGNED, SEALED & DATED | | | BY THE ENGINEER AS REQUIRED PER FS | | | 471.05.PLEASE HAVE THE ENGINEER COMPLY | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-07 |
Time |
09:34 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2004-05-07 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2004-05-07 00:00:00 | PLANS SUBMITTED WITH PERMIT 04030555 | | | DENIED: | | | RESPONSE LETTER DATED 4-16-04 TO | | | COMMENTS FROM REVIEW DATED 4-7-04: | | | | | | RESPONSE #2 | | | CO-SENSORS SETTING DETERMINED BY OWNER. | | | PER 2001 FBC(M) 403.4, FANS SHALL | | | OPERATE AUTOMATICALLY UPON DETECTION OF | | | A CONCENTRATION OF CO OF 25 PPM BY | | | APPROVED DETECTION DEVICE.PLEASE | | | PROVIDE SUBMITTAL OF THE CO SENSOR. | | | | | | RESPONSE #4 | | | WAITING RETURN CALL FROM INSPECTOR | | | CLARIFICATION.PLEASE CONTACT CHIEF | | | MECHANCIAL INSPECTOR HAROLD MOSER, AT | | | (561) 805-6732.THE BEST TIME TO | | | CONTACT MR. MOSER IS BETWEEN 7:00 AM - | | | 8:00 AM OR 3:00 PM - 4:00 PM MONDAY | | | THROUGH FRIDAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-10 |
Time |
07:17 |
Rev Time |
3.00 |
| Received By |
pkrauss |
Date |
2004-04-10 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2004-04-10 00:00:00 | DENIED: | | | 1.PLAN SHEET M-1 INDICATES CO SENSORS | | | CONTROLLING THE EXHAUST FANS.IS IT THE | | | DESIGN INTENT EXHAUST FANS WILL NOT RUN | | | CONTINUOUSLY? | | | | | | 2.INDICATE AT WHAT LEVEL(PPM) THE CO | | | SENSORS ARE SET TO ACTIVATE THE EXHAUST | | | FANS. | | | | | | 3.PLEASE CLARIFY RETURN AI TO THE | | | RTU.WILL THESE UNITS BE CONTROLLED BY | | | A THREMOSTAT OR A HUMIDISTAT? | | | | | | 4.PLEASE NOTE PER 2002 NFPA 90A | | | 4.3.7.1, AIR SHALL NOT BE RECIRCULATED | | | FROM ANY SPACE IN WHICH FLAMMABLE VAPORS | | | OR DUST ARE PRESENT IN QUANTITIES OR | | | CONCENTRATIONS THAT WOULD INTRODUCE A | | | HAZARDOUS CONDITION INTO THE RETURN AIR | | | SYSTEM.SEE ALSO 2001 FBC(M) 502.1. | | | | | | 5.SEE COMMENT #3 FROM K. STEVENS | | | (PLUMBING). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-07-22 |
Time |
15:14 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | | | | CONTR. SUBMITTED PROPER ENGINEERING FOR | | | CONDEN. PIPE | | | | | | L. MARTINEZ |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-06 |
Time |
12:15 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-06-22 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: NO RESPONSE TO | | | COMMENT TO INDICATE HOW PIPE SUPPORTS | | | WILL BE ATTACHED TO THE ROOF. SECTION | | | 104.2.1 | | | 2) FROM PREVIOUS REVIEW: NO RESPONSE TO | | | COMMENTS CONCERNING SEAL, SIGNITURE, AND | | | DATE REQUIRED ON THE LANDSCAPE, SURVEY, | | | CIVIL AND MECHANICAL SHEETS FOR THE | | | LIFTS. ALL LANDSCAPE SHEETS ARE NOT SIG- | | | NED AND SEALED AND NONE SHOW LICENSE | | | NUMBER, CERTIFICATE OF AUTHORIZATION | | | NUMBER OR PRINTED NAME OF ARCHITECT. | | | - THE SURVEY SHEET IS NOT SIGNED, SEALED | | | AND DATED AS REQUIRED IN FS 472.025. | | | - THE SEAL FOR THE CIVIL SHEET SHOW NO | | | INFORMATION. SEAL SHALL BE IMPRESSION | | | TYPE WITH ALL INFORMATION REQUIRED BY | | | FLORIDA STATUTES. | | | - MECHANICAL SHEETS FOR LIFTS HAVE BEEN | | | SIGNED, SEALED, AND DATED AND ARE OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-22 |
Time |
11:24 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-05-22 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2004-05-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE | | | FLORIDA STATUTES | | | | | | 1) SHT R-01 CONDENSATE LINES. INDICATE | | | MATERIAL BEING USED FOR CONDENSATE LINES | | | RESPONSE NOTED, BUT NO MATERIAL SHOWN. | | | INDICATE HOW PIPE SUPPORTS WILL BE ATT- | | | ACHED TO ROOF. SUPPORTS TO BE SPACED PER | | | TABLE 308.5. SECTION 104.2.1 | | | 2) SHT R-01 IS NOT SIGNED, DATED OR | | | SEALED AS REQUIRED IN FAC 61G15-002(1) & | | | (2) NOR IS THERE A CERTIFICATE OF AUTHOR | | | IZATION AS REQUIRED IN FAC 61G15-002(2) | | | & FS 471.025. ENGINEER | | | 3) IF THE ARCHITECT IS RESPONSIBLE FOR | | | SHEET R-01 THEN HE/SHE SHALL SIGN, DATE | | | AND SEAL THE PLANS PER FAC61G1-16.003 | | | AND FS 481.2055 | | | 4) ALL PLANS SUBMITTED FOR PLUBLIC | | | RECORED SHALL BE SIGNED, SEALED, AND | | | DATED. ALL TITLE BLOCK INFORMATION WITH | | | APPROIATE LICENSES, ADDRESS ECT SHALL BE | | | ON EACH SHEET. (SEE SHEETS FOR LANDSCAPE | | | SURVEY, CIVIL, AND MECHANICAL SHEETS FOR | | | THE LIFTS). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-16 |
Time |
17:22 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2004-03-16 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2004-03-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) CONTACT RODNEY COMPO ENVIRONMENTAL | | | COMPLIANCE TO DETERMINE IF A SAND-WATER/ | | | OIL SEPARATOR WILL BE REQUIRED. WASTE | | | ORD 2938-96. (561) 837-4074. | | | 2) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE. SECTION 608.13.2 | | | 3) SHT B.A-9.1 SHOWER STALL SHALL BE | | | ACCESSIBLE PER SECTION 11-4.21 AND ALL | | | SUBSECTIONS. PROVIDE A DETAIL. | | | 4) SHT R-01 CONDENSATE LINES. INDICATE | | | MATERIAL BEING USED FOR CONDENSATE LINES | | | IF PVC, SUPPORTS SHALL BE 4' O/C PER | | | TABLE 308.5. ALSO PIPE SHALL BE PROTECT- | | | ED FROM U.V. RAYS PER MANUF. INSTALLAT- | | | ION INSTRUCTIONS. | | | 5) SHTS P-1 & P-3 INDICATE SLOPE OF PIPE | | | FOR STORM SEWERS. MINIMUM 1/4" PER FOOT | | | PER TABLE 1106.3. IS STORM LINES ARE | | | TIED TOGETHER, SUBMIT A STORM SEWER DIA- | | | GRAM INDICATING SEWER PIPE SIZES AND | | | SLOPE OF PIPE AND INDICATE TERMINATION | | | OF STORM SEWER. | | | 6) SHT P-6 WATER RISER DIAGRAM. WATER | | | HAMMER ARRESTORS SHALL BE LOCATED AT ALL | | | QUICK CLOSING VALVES PER SECTION 604.9. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE RANGE | | | NOT AT THE TOP OF DROPS. PDI-WH 201 AND | | | MANUF. INSTALL. INSTRUCTIONS. | | | 7) SHT P-6 EWH DETAIL. P/T RELIEF VALVE | | | SHALL TIE INTO THE TOP 6" OF THE WATER | | | HEATER PER SECTION 504.5.1. | | | 8) CERTIFICATE OF AUTHORIZATION SHALL BE | | | INDICATED ON EACH PLUMBING AND ELECTRIC- | | | AL SHEET. MECHANICAL SHEETS ARE NOT | | | SIGNED AND SEALED. | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-10 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-10 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | APPROVED BY JOSH LONG, SENIOR PLANNER | | | 822-1449 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-29 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-11 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | APPROVED BY JOSH LONG, PLANNER 659-8031 | | | LETTER ATTACHED MM |
|
|