| Plan Review Stops For Permit 04030532 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
P |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-13 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-13 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2008-11-13 10:09:11 | NOA FOR ROOF DECK WATERPROOFING, APPROVED BY ARCHITECT | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-10-30 |
Time |
15:34 |
Rev Time |
1.00 |
| Received By |
amorse |
Date |
2008-10-30 |
Time |
15:34 |
Sent To |
PC |
|
| Notes |
| 2008-10-30 15:36:26 | | | | | | | PASSED | | | | | | REVISION #15 FOR SITE SPECIFIC CUSTOM OUTSWING CYPRESS | | | DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
F |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-30 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2008-10-30 14:20:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. THE PRODUCT SUBMITTED, SONOGUARD, IS NOT RECOMMENDED | | | FOR USE ON A POOL DECK. PLEASE CONTACT THE | | | MANUFACTURER, 800-243-6739. THEIR TECHNICAL DEPARTMENT | | | INFORMED ME THAT THE CHLORINE AND OTHER POOL CHEMICALS | | | MAY INTERACT WITH THE WATERPROOFING PRODUCT YOU PROPOSE | | | TO USE. | | | | | | 2. PLEASE PROVIDE INFORMATION REGARDING HOW THIS | | | PRODUCT WILL RESIST WIND LOADS, FBC1503.1. | | | | | | **REVIEW DONE PER KS REQUEST** | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
F |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-10-17 |
Time |
16:16 |
Rev Time |
1.00 |
| Received By |
amorse |
Date |
2008-10-17 |
Time |
16:16 |
Sent To |
PC |
|
| Notes |
| 2008-10-17 16:27:20 | | | | | | | DENIED | | | | | | 1) AN APPLICATION FOR SITE SPECIFIC PRODUCT APPROVAL | | | MUST BE FILLED OUT AND SUBMITTED WITH ALL REQUIRED | | | DOCUMENTATION (SEE REVERSE OF APPLICATION) AND IN LUE | | | OF THIRD PARTY QUALITY ASSURANCE (SEE #7) THE ENGINEER | | | OF RECORD SHALL PROVIDE 1) A LETTER OF COMMITMENT TO | | | PROVIDE ON SITE INSPECTION OF PRODUCT AND ITS | | | ATTACHMENT. 2) UPON COMPLETION OF JOB AND BEFORE CO A | | | LETTER OF COMPLIANCE STATING THAT PRODUCT WAS INSTALLED | | | PER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2004 | | | AND THE ENGINEERED DESIGN CRITERIA SPECIFIED IN | | | DRAWINGS. | | | | | | 2) THE PRODUCT REVISION FOR THE SECTIONAL GARAGE DOOR | | | HAS BEEN APPROVED AND CAN BE REMOVED FROM THE PACKAGE, | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2008-10-11 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-10-11 |
Time |
09:36 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2008-10-11 |
Time |
09:36 |
Sent To |
PC |
|
| Notes |
| 2008-10-11 09:37:04 | | | | | | | RESTAMP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-07-17 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-07-17 |
Time |
15:24 |
Sent To |
PC |
|
| Notes |
| 2008-07-17 15:25:20 | | | | | | | PASSED | | | | | | REVISION TO CHANGE FRECH DOOR PRODUCT AND PRODUCT | | | APPROVALS FOR EXTERIOR DOORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2008-06-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-06-28 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-06-28 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
| 2008-06-28 07:46:15 | | | | | | | REVISION | | | | | | DENIED | | | | | | 1)PRODUCT APPROVAL FOR THERMA-TRU DOOR IS INCOMPLETE, | | | ONLY AN EVALUATION REPORT WAS SUBMITTED, IS THIS PART | | | OF A STATEWIDE FLORIDA PRODUCT APPROVAL IF SO PROVIDE | | | THE COVER SHEETS , ALSO SHOULD BE A DRAWING WITH THE | | | ATTACHMENT AND DESIGN PRESSURES AS PART OF APPROVAL | | | (SEE BOTTOM OF EVALUATION REPORT) | | | | | | 2)THE THERMA-TRU IS FOR A SINGLE GLAZED DOOR, NO | | | SINGLE GLAZED DOORS ARE LISTED IN THE DOOR AND WINDOW | | | SCHEDULES ON SHEETS 6,7 AND8 OF DRAWINGS, PLEASE | | | SUBMIT REVISED SHEETS WITH UPDATED SCHEDULES WHERE | | | REQUIRED. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2008-06-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-06-28 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-06-28 |
Time |
06:38 |
Sent To |
PC |
|
| Notes |
| 2008-06-28 06:39:09 | | | | | | | RESTAMP OF 4 PRODUCT APPROVALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-11-06 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-11-06 |
Time |
18:48 |
Sent To |
M |
|
| Notes |
| 2007-11-06 18:51:42 | | | | | | | BLDG REVISIONS OK, MOVING OF AIR HANDLERS WILL REQUIRE | | | REVISED MECHANICAL DRAWINGS TO BE SUBMITTED. SENT TO | | | MECHANICAL REVIEWER TOM GORDON. | | | | | | ADRIAN MORSE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-09-25 |
Time |
19:08 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-09-25 |
Time |
19:08 |
Sent To |
PC |
|
| Notes |
| 2007-09-25 19:10:20 | | | | | | | PRODUCT APPROVAL SUBMITTED ONLY ONE COPY AND NOT THE | | | SAME AS ORIGINAL PERMIT $60.00 REVISION FEE CHARGED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-09-11 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-09-11 |
Time |
19:17 |
Sent To |
PC |
|
| Notes |
| 2007-09-11 19:23:33 | | | | | | | "RESTAMP ONLY"OF BUILDING DRAWINGS | | | | | | PLEASE NOTE THAT A/C DRAWINGS DO NOT MATCH PERMIT SET | | | ON FILE AND CONTRACTOR HAS CHANGED. A NOTARIZED CHANGE | | | OF CONTRACTOR FORM IS REQUIRED AND THE 2 SETS OF | | | MECHANICAL DRAWINGS MUST BE SUBMITTED AS A REVISION TO | | | THE PERMIT SET | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-08-18 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-08-18 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-08-18 |
Time |
15:37 |
Sent To |
PC |
|
| Notes |
| 2007-08-18 15:43:06 | | | | | | | DENIED | | | | | | 1)PROVIDE ORIGINAL SIGNED AND SEALED COPIES FOR | | | RESTAMP. A DESIGN PROFESSIONAL THAT IS REGISTERED TO | | | PRACTICE UNDER CHAPTER 481 OR 471 OF | | | THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, | | | SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS | | | PER 106.1 FBC 2004 | | | | | | 2)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED | | | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND | | | LICENSE #, AS WELL AS THE NAME,ADDRESS AND CERTIFICATE | | | OF AUTHORIZATION #ON EACH SHEET PER | | | 61G15-23.002 (2) FAC *** NO CA # IS PRESENT ON THE | | | ENGINEERS TITLE BLOCK**** | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-08-18 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-08-18 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-08-18 |
Time |
13:38 |
Sent To |
PC |
|
| Notes |
| 2007-08-18 13:57:43 | | | | | | | DENIED | | | | | | 1)ELEVATION CERTIFICATE HAS NOT BEEN SIGNED IN | | | SECTION D BY SURVEYOR | | | | | | 2)SURVEY DOES NOT SHOW A/C PADS, ON FINAL ELEVATION | | | CERTIFICATE AND SURVEY ANY A/COR GENERATOR EQUIPMENT | | | PADS SHALL BE 6" ABOVE FLOOD ELEVATION PER FEMA | | | REQUIREMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-04-06 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-04-06 |
Time |
09:59 |
Sent To |
PC |
|
| Notes |
| 2007-04-06 10:15:08 | | | | DENIED | | | | | | 1) CASEMENT SIZES ON DRAWINGS FOR OPENING 16,17AND 38 | | | EXCEED THE MAX. WIDTH FOR A SINGLE CASEMENT IN THE | | | NOA, ALSO SPECIFY THE GLASS TYPE THAT WILL BE USED AS | | | SOME DO NOT MEET YOUR DESIGN PRESSURES ON THE | | | DRAWINGS. | | | | | | 2) FIXED UNITS WILL ONLY MEET DESIGN PRESSURES IF GLASS | | | TYPE B & D ARE USED PLEASE SPECFIY GLASS TYPE ON | | | SUBMITTAL. | | | | | | 3) VERIFY MULLION SIZE AND THICKNESS AS NOT ALL WILL | | | WORK WITH THE DESIGN PRESSURES ON DRAWINGS. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-12 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-12 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2006-10-12 10:27:06 | DENIED | | | | | | 1.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY | | | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL | | | ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 2.ARE THE PRODUCT APPROVALS SUBMITTED FOR A CHANGE | | | OF PRODUCT OR ARE YOU ADDING TO THJE SCOPE OF WORK OF | | | THE PROJECT.REVISION FORM WAS NOT COMPLETED. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-12 |
Time |
09:31 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-04-12 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | TRUSS DRAWING REVIEW OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-29 |
Time |
15:28 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-03-29 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-03-29 00:00:00 | TRUSS SUBMITTAL DENIED | | | | | | ENGINNEERS SEALS AFTER JANUARY 1, 2006 | | | SHALL BE SHOWN AS "LICENSED" NOT | | | "CERTIFICATE" | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-09 |
Time |
15:32 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2004-06-09 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-09 |
Time |
08:55 |
Rev Time |
4.00 |
| Received By |
alange |
Date |
2004-04-19 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | DENIED | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2. BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.ENERGY CALCS NOT SIGNED. | | | | | | 4.BUILDING VALUATION TOO LOW BASED | | | UPON SBCCI BUILDING VALUATION TABLES. | | | THE REVISED VALUATION IS $398,463. | | | ADDITIONAL PERMIT FEES ARE DUE. | | | | | | 5.SPIRAL STAIRWAYS. FBC 1007.8.2.1 6. | | | THE TURN OF THE STAIRWAY SHALL BE SUCH | | | THAT DESCENDING USERS HAVE THE OUTER | | | HANDRAIL AT THEIR RIGHT SIDE.REVISE | | | PLAN TO SHOW THIS. | | | | | | 6.EXIT REQIREMENTS.FBC 1005 | | | BEDROOM EGRESS WINDOWS SHALL COMPLY | | | WITH THIS SECTION. WINDOWS LISTED DO | | | NOTMEET EMERGENCY ESCAPE AND RESCUE | | | OPENINGREQUIREMENTS. | | | 23,25,34,35,36,37,38,9,10,14,15,19.I | | | CHECKED THESES AGAINST PGT EGRESS SIZE | | | SUMMARY CHARTS. | | | | | | 1015.2 HEIGHT. GUARDRAILS SHALL | | | FORM A VERTICAL PROTECTIVE BARRIER NOT | | | LESS THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT | | | WILLREJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE. | | | SHOW DETAIL ON PLAN. | | | | | | 8.SPECIFY CONSTRUCTION TYPE IS IT | | | TYPE 5 OR TYPE 6 1 HR. PROTECTED. | | | | | | 9.SPRINKLERS REQUIRED PER TABLE 600 | | | FBC.SUBMIT SHOP DRAWINGS. | | | | | | 10.SHOW ELEVATOR SHAFT PROTECTION | | | DETAIL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-23 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-23 |
Time |
07:47 |
Sent To |
P |
|
| Notes |
| 2007-10-23 08:32:10 | | | | | | | TO JOHN'S DESK./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-08 |
Time |
13:29 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-06-08 |
Time |
10:56 |
Sent To |
M |
|
| Notes |
| 2004-06-08 00:00:00 | PROVISO | | | ~~~~~~~ | | | 1} PLEASE SEE MISSING RECEPTACLES | | | FRONT AND/OR REAR OF DWELLING PER | | | 210.52(E).THE ONES THAT WERE ADDED TO | | | THE RESUB SET ARE HAND DRAWN. CHANGES | | | MUST BE MADE MY THE ARCHITECT OF RECORD | | | PER 61G1-16.003 FAC.* | | | | | | 2} PLEASE SEE MISSING RECEPT REQUIRED | | | FOR A/C EQUIPMENT. 210.63. AGAIN RESUB | | | CORRECTION WAS HAND DRAWN, SEE PREVIOUS | | | NOTE.* | | | | | | 3} INDICATE COMPLIANCE WITH 225.31 & | | | 250.32 AT THE STORAGE BUILDING.* | | | | | | 4} THE RESUBMITTED PLANS ARE STILL NOT | | | IN COMPLIANCE WITH 8-1.4.1.6.2 NFPA-72. | | | THE DETECTORS MUST BE LOCATED "IN" ALL | | | SLEEPING ROOMS. ALSO ON EACH ADDITIONAL | | | STORY,THAT WOULD INCLUDE THE 3RD FLOOR.* | | | | | | 5} MANY OF THE APPLIANCES THAT WERE | | | LISTED IN THE ORIGINAL CALC'S HAVE BEEN | | | DELETED FROM THE RESUB SET. PLEASE NOTE | | | THAT IF THESE ARE ADDED BACK LATER A | | | REVISED LOAD CALCULATION MUST BE | | | RESUBMITTED AS A REVISION. PLEASE CHECK | | | THE NUMBERS TO INSURE THE SERVICE WILL | | | BE SUFFICIENT. THE ITEMS LEFT OFF TOTAL | | | 19480 WATTS. ALSO THE WATER HEATER | | | APPEARS TO BE UNDERSIZED FOR THE SIZE | | | OF THE RESIDENCE. | | | | | | 6} THE RATINGS OF THE A/C EQUIPMENT ON | | | THE ELECTRICAL CALC AND THE MECHANICAL | | | SHEETS DO NOT CORRESPOND. IF THE | | | MECHANICAL SHEETS ARE CORRECT THERE IS | | | A 10 KW ERROR IN THE LOAD CALC'S.PLEASE | | | CORRELATE THE INFORMATION. CHECK THE | | | CALC'S! | | | | | | 7} PLEASE REMOVE THE #2 GND CONUCTOR | | | FROM THE METER TO THE MAIN DISCONNECTS | | | PER 250.4(B). IT CREATES A PARALLEL | | | GROUND PATH. | | | | | | 8} RECEPTACLES NEED TO BE ADDED IN BED | | | ROOMS #2 & 3 TO COMPLY WITH 210.52. | | | | | | 9} THE DISCONNECTS AT THE CONDENSING | | | UNITS DO NOT APPEAR TO COMPLY WITH | | | 110.26. | | | | | | 10} THE DATE THE PLANS WERE SEALED MUST | | | BE ON THE TITLE BLOCK.61G-16.004(4).* | | | | | | NOTE: THE COMMENTS FOLLOWED BY AN | | | ASTERISK WERE ON THE PREVIOUS REVIEW. | | | SEE FS. 553.80(2)(B), ATTACHED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
15:26 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-03-24 |
Time |
07:21 |
Sent To |
M |
|
| Notes |
| 2004-03-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALL-ED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BERATED FOR THE AVAILABLE FAULT | | | CURRENT. | | | PER 110.9/215.5 | | | | | | 2} LOAD CALCS ARE INCOMPLETE, THERE ARE | | | NO TOTALS, AIR CONDITIONING TABLES ARE | | | EMPTY. | | | | | | 3} PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 4} PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 5} PLEASE SEE MISSING RECEPTS FOR | | | FRONT AND/OR REAR OF DWELLING. | | | 210.52(E). | | | | | | 6} PLEASE SHOW COMPLIANCE FOR | | | DISCONNECTING MEANS PER 225.31, FOR | | | "STORAGE" BLDG. | | | | | | 7} THERE IS NO CIRCUIT LISTED ON PANEL | | | SCHEDULE OR CALCULATION FOR THE | | | ELEVATOR EQUIPMENT. | | | | | | 8} PLEASE SEE MISSING RECEPT REQUIRED | | | FOR A/C EQUIPMENT. 210.63 | | | | | | 9} PLEASE INDICATE COMPLIANCE WITH | | | NFPA-72 & THE FLORIDA BUILDING CODE AND | | | PLACE SMOKE DETECTORS IN ALL REQUIRED | | | LOCATIONS. | | | | | | 10} PLEASE NOTE THAT TWO OF THE | | | RECEPTACLES AROUND THE POOL DO NOT | | | COMPLY WITH THE 10' MINIMUM, ARTICLE | | | 680.22(A)(2). | | | | | | 11} PLEASE SEE RECEPTACLES SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5 | | | | | | 12} PLEASE NOTE PER 61G1-16.004(4), THE | | | DATE SEALED MUST BE ON THE TITLE BLOCK. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-07 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-07 |
Time |
17:03 |
Sent To |
B |
|
| Notes |
| 2008-11-07 17:04:12 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-27 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-27 |
Time |
08:56 |
Sent To |
B |
|
| Notes |
| 2008-10-27 08:57:14 | TO "AMORSE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2008-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-14 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-14 |
Time |
09:32 |
Sent To |
I |
|
| Notes |
| 2008-10-14 09:33:04 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-06 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-06 |
Time |
16:57 |
Sent To |
B |
|
| Notes |
| 2008-10-06 16:57:17 | TO "AMORSE" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-08 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-08 |
Time |
10:17 |
Sent To |
P |
|
| Notes |
| 2008-08-08 10:17:55 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-30 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-30 |
Time |
14:00 |
Sent To |
Z |
|
| Notes |
| 2008-07-30 14:01:12 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-15 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-15 |
Time |
16:28 |
Sent To |
Z |
|
| Notes |
| 2008-07-15 16:29:05 | TO "AMORSE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-15 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-15 |
Time |
16:24 |
Sent To |
Z |
|
| Notes |
| 2008-07-15 16:25:33 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-23 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-23 |
Time |
09:15 |
Sent To |
Z |
|
| Notes |
| 2008-06-23 09:15:34 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2008-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-23 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-23 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2008-06-23 08:56:09 | TO "AMORSE" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-23 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-23 |
Time |
08:52 |
Sent To |
B |
|
| Notes |
| 2008-06-23 08:52:35 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
08:16 |
Sent To |
Z |
|
| Notes |
| 2008-06-06 08:16:52 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-14 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-14 |
Time |
14:10 |
Sent To |
M |
|
| Notes |
| 2008-02-14 14:10:39 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-05 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-05 |
Time |
13:16 |
Sent To |
M |
|
| Notes |
| 2008-02-05 13:17:06 | TO "M" BOX/ 1SUBMITTAL AND 1 REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-26 |
Time |
13:42 |
Sent To |
M |
|
| Notes |
| 2007-11-26 13:42:29 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-18 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-18 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
| 2007-10-18 08:34:47 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-24 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-24 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
| 2007-09-24 14:30:24 | TO "AMORSE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-06 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2007-09-06 16:43:58 | TO "AMORSE" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-13 |
Time |
13:50 |
Sent To |
B |
|
| Notes |
| 2007-08-13 13:50:40 | TO "AMORSE" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
09:18 |
Sent To |
B |
|
| Notes |
| 2007-08-10 09:18:59 | TO AM'S INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-11 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-11 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2007-01-11 09:53:41 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-05 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-05 |
Time |
13:16 |
Sent To |
B |
|
| Notes |
| 2006-10-05 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-05 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-05 |
Time |
13:43 |
Sent To |
B |
|
| Notes |
| 2006-04-05 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-17 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-17 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
| 2006-03-17 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
| 2004-06-07 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-07 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
08:08 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-18 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2004-03-19 00:00:00 | TO SFD RACK/E | | 2004-03-11 00:00:00 | TO Z |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-08-05 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-08-05 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-07-23 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-07-23 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2008-07-23 09:38:07 | PROVIDE SIZE AND SPACING FOR ALL PROPOSED PLANT | | | MATERIAL--NOT CONTAINER SIZE. | | | | | | MUST ABIDE BY GUIDELINES ESTABLISHED BY FPL FOR | | | PLANTING TREES NEAR OR UNDER POWER LINES.CHECK THE | | | FPL WEBSITE AND LOOK UP "PLANT THE RIGHT TREE IN THE | | | RIGHT PLACE" FOR A LIST OF APPROVED TREES.THE | | | PROPOSED SILVER TRUMPET TREE IN THE REAR OF THE SITE IS | | | SHOWN TOO CLOSE TO OVERHEAD POWER LINES.MOVE TREE OR | | | CHANGE SPECIES.STAFF WOULD SUGGEST THAT THE EXISTING | | | LARGE TREES IN THE REAR OF THE SITE BE REMOVED, AND | | | REPLACED WITH TREES THAT CONFORM WITH THE FPL | | | GUIDELINES, THOUGH IT IS NOT REQUIREDWITH THIS | | | APPLICATI'PLANT THE RIGHT TREE IN THE RIGHT PLACE' | | | GUIDELINES". | | | | | | MUST APPLY FOR A TREE ALTERATION PERMIT THROUGH | | | PLANNING AND ZONING DEPARTMENT IF ANY EXISITNG TREES ON | | | SITE WILL BE REMOVED OR RELOCATED. | | | | | | CONTACT ROBERT KUSSNER @ (561) 822-1462 IF YOU HAVE ANY | | | QUESTIONS REGARDING THE LANDSCAPE COMMENTS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-15 |
Time |
11:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-02-15 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2008-02-15 11:37:08 | REVISION TO MECH. PLANS PAGES M1, M2, AND M3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-06 |
Time |
09:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-02-06 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2008-02-06 09:05:22 | PLAN REVIEW UNDER THE 2001 FLORIDA BUILDING CODE, CITY | | | OF WEST PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), | | | FLORIDA ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA | | | STATUTES (F.S.). | | | | | | ** REVISION TO MECHANICAL PLANS M-1, M-2, & M-3 ** | | | | | | *** DENIED *** | | | 1) CHANGES TO PLANS MAY NOT BE DONE BY PEN, PENCIL, OR | | | BY HAND, NO WHIGHT-OUT MAY BE USED ON PLANS. | | | | | | 2) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN ON | | | THEM, SEE W.P.B. AMEND. 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-05 |
Time |
16:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-02-05 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2008-02-05 16:44:18 | REVISION TO ENERGY CALCULATIONS AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-30 |
Time |
10:10 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-11-30 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-11-30 10:26:29 | PLAN REVIEW UNDER THE 2001 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2003 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL REVISION | | | *** DENIED *** | | | | | | 1) NEED TO SHOW THE SIZES OF THE SUPPLY AIR TRUNK LINE | | | AND ONE RETURN AIR DUCT ON THE SECOND FLOOR (SEE YELLOW | | | HIGH LIGHT ON MECHANICAL PLAN. | | | | | | 2) NEED TO SHOW THE CFM'S AT ALL SUPPLY AIR GRILLS ON | | | SECOND AND THIRD FLOORS. | | | | | | 3) NEED TO ADD AN EQUIPMENT LISTING TO THE MECHANICAL | | | PLAN SHOWING EQUIPMENT BEING INSTALLED AND ALL | | | PERTINENT INFORMATION. | | | | | | 4) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN ON | | | THEM. | | | | | | 5) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-07 |
Time |
09:19 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-07 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2007-11-07 09:23:44 | REVISION TO BUILDING & ELECT. PLANS. | | | *** PROVISO *** | | | 1) ENERGY CALCULATIONS AND MECHANICAL PLANS WILL NEED | | | TO BE REVISED, PER 2001 FBC 106.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-09 |
Time |
14:51 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-06-09 |
Time |
08:54 |
Sent To |
B |
|
| Notes |
| 2004-06-09 00:00:00 | APPROVED 4-2-04 NO CHANGES ON THE | | | RESUBMITTAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-08 |
Time |
13:30 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-02 |
Time |
13:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-30 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-30 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-30 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2008-10-30 11:44:54 | REVISION OK -- SHEET P-1 ROOF DRAIN LOCATIONS & | | | SCUPPERS FOR POOL DECK AREA. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-12 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-11 |
Time |
14:58 |
Sent To |
PC |
|
| Notes |
| 2008-08-11 16:48:39 | PLUMBING PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2001 FLORIDA BUILDING CODES WITH | | | REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. PLEASE | | | KNOW THAT THIS IS A REVISION NOT A SUBMITTAL AND A FEE | | | OF $60.00 IS DUE FOR THIS REVISION PLAN REVIEW AND WILL | | | NEED TO BE PAID FOR AS WELL AS THE CORRECTIONS TO THIS | | | REVISION PRIOR OF THE NEXT REVISION SUBMITTED FOR PLAN | | | REVIEW. | | | | | | 1. INFORMATION IS MISSING FROM THE TITLE BLOCK. | | | PRINTED NAME AND LICENSE NUMBER OF THE PERSON SIGNING | | | AND SEALING PLAN SHEETS AS WELL AS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE FIRM IS MISSING FROM PLAN | | | SHEETS. PER CHAPTER 481 AND FAC 61G1-16.004 TITLE | | | BLOCK. | | | | | | 2. THE SUBMITTED RISER DIAGRAM FOR THE SECOND AND | | | THIRD FLOOR ROOF DRAINS REQUIRES MORE INFORMATION. | | | PLEASE PROVIDE A ROOF PLAN THAT INDICATES HOW THE ROOF | | | OR DECK WILL BE PITCHED TO PROPERLY DRAIN, AND INDICATE | | | THE FOLLOWING INFORMATION PER THE FOLLOWING CODE | | | REFERENCES. | | | A} DETAIL OF ROOF INDICATING SQUARE FOOTAGE OF ROOF | | | AND VERTICAL WALLS (PARAPHET) DRAINING TO DOWNSPOUTS | | | AND SCUPPERS TO VERIFY COMPLIANCE WITH FBC-2001 | | | PLUMBING, SECTION 1101.1 SCOPE. | | | B} VERTICAL CONDUCTORS AND LEADERS, PER FBC-2001 | | | PLUMBING, SECTION 1106.2. | | | C} VERTICAL WALLS, PER FBC-2001 PLUMBING, SECTION | | | 1106.4. | | | D} SCUPPERS, (PROVIDE DETAIL PER FBC-2001 BUILDING, | | | SECTIONS 1503.4.2) SIZE PER FBC-2004 PLUMBING, SECTION | | | 1107. | | | E} SECONDARY (EMERGENCY) ROOF DRAINS, PER FBC-2001 | | | PLUMBING, SECTION 1107. | | | A) SECONDARY DRAINAGE REQUIRED, PER FBC-2001 PLUMBING, | | | SECTION 1107.1. | | | B) SEPERATE SYSTEMS REQUIRED PER FBC-2001 PLUMBING, | | | SECTION 1107.2. | | | C) SIZING OF SECONDARY DRAINS, PER FBC-2001 PLUMBING, | | | SECTION 1107.3 | | | F) PROTECTION AGAINST DECAY AND TERMITES, PER FBC-2001 | | | BUILDING, SECTION 1504.4 (SHALL DISCHARGE A MINIMUM OF | | | 1 FOOT AWAY FROM STRUCTURE). | | | | | | 3. PLEASE CLARIFY IF THESE ROOF DRAINS ARE FOR THE | | | BALCONY AREA INDICATED ON SHEET 07 AND THE POOL DECK | | | AREA ON SHEET 08. PLEASE KNOW THAT IF THIS IS THE | | | LOCATION FOR THESE ROOF DRAINS THAT THE SUBMITTED DRAIN | | | SPECIFICATION SHEET IS NOT COMPLIANT FOR A FLAT DECK. | | | PER 1105.2 FLAT DECKS. STRAINERS FOR A FLAT SURFACE | | | SHALL NOT BE LESS THAN TWO TIMES THE AREA OF THE | | | CONDUCTOR OR LEADER TO WHICH THE DRAIN IS CONNECTED. | | | SUBMITTED PLANS ARE INDICATING A 3 INCH LEADER.NOTE: | | | PER FLAT DECK STRAINER CALCULATIONS FOR A 3 INCH LEADER | | | (DIAMETER SQUARED TIMES .7854 OR 3 X 3 X .7854 = | | | 14.1372) A 14.1372 INCH FLAT STRAINER IS REQUIRED. | | | DRAIN SUBMITTED IS LESS THAN 10 INCH. | | | | | | 4. PROVIDE A DETAIL ON HOW THE ROOF DRAIN OR FLAT DECK | | | DRAIN WILL BE INSTALLED PER THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. PER FBC-2001 PLUMBING | | | SECTION 1101.1 SCOPE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-05 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-05 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2007-11-05 07:28:08 | NO PLUMBING REVISIONS. GAS ONLY REVISIONS BY GAS | | | CONTRACTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-20 |
Time |
13:00 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-03-20 |
Time |
13:00 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-24 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-07-23 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2008-06-24 13:39:48 | ***FAILED - REVISION (1ST RESUB. OF THIS REV.) - | | | LANDSCAPE PLAN*** | | | | | | | | | REPEAT COMMENT: | | | | | | 1)AS LANDSCAPING IS PROPOSED WITHIN THE REAR UTILITY | | | EASEMENT, APPROVAL/RELEASE FORMS SHALL BE OBTAINED FROM | | | ALL UTILITIES:COMCAST, BELLSOUTH, FP&L, FLORIDA | | | PUBLIC UTILITIES, AND CITY OF WPB PUBLIC UTILITIES. | | | WHY HAVE YOU RESUBMITTED WITHOUT ALL OF THESE? | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-12 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-12 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2008-06-12 09:32:11 | ***FAILED - REVISION - LANDSCAPE PLAN*** | | | | | | | | | 1)AS LANDSCAPING IS PROPOSED WITHIN THE REAR UTILITY | | | EASEMENT, APPROVAL/RELEASE FORMS SHALL BE OBTAINED FROM | | | ALL UTILITIES:COMCAST, BELLSOUTH, FP&L, FLORIDA | | | PUBLIC UTILITIES, AND CITY OF WPB PUBLIC UTILITIES. | | | | | | 2)LANDSCAPE PLAN SHALL SHOW PROPERTY LINE | | | DIMENSIONS, PRINCIPAL STRUCTURE FOOTPRINT DIMENSIONS, | | | AND A DATA TABLE SHOWING CALCULATIONS REGARDING | | | REQUIRED NUMBER OF TREES/SHRUBS AND PROVIDED | | | TREES/SHRUBS. | | | | | | | | | NOTE:FOR SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE | | | SHADE, FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR | | | EACH 1,200 SQUARE FEET OF OPEN SPACE OR PORTION | | | THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE | | | SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN | | | SPACE OR PORTION THEREOF. | | | | | | NOTE:PLANT QUALITY.PLANT MATERIALS SHALL BE EQUAL | | | TO OR BETTER THAN FLORIDA DEPARTMENT OF AGRICULTURE | | | NUMBER 1 NURSERY GRADE STANDARD. | | | | | | NOTE:THE REQUIRED IRRIGATION SYSTEM SHALL BE | | | INSTALLED WITHIN THE YARD AS WELL AS ANY SWALE/PARKWAY | | | AREAS (IF APPLICABLE). | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-09 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-09 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2004-06-09 00:00:00 | MUST PULL A SEPARATE PERMIT FOR WALL MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-07 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-07 |
Time |
12:16 |
Sent To |
I |
|
| Notes |
| 2004-06-07 00:00:00 | DENIED | | | 1 - PLANS SHOWS HEIGHT OF 35FT, SHAFT | | | EXCEEDS BLDG OF 33FT. | | | 2 - SOUTHSIDE OVER HANG SHOULD BE 18" & | | | PLANS SHOWS 2FT. | | | CALLED SHANE, ARCHITECT AND LEFT MSG | | | 3 - MUST PULL A SEPARATE PERMIT FOR WALL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-17 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
| 2004-03-18 00:00:00 | DENIED, DOES NOT MEET THE 25FT FRONT | | | SETBACK.NEED TO REDESIGN PLANS AND | | | PROVIDED NEW SURVEY.CAN ONLY ENROACH | | | 3FT INTO FRONT SETBACK.TOO MUCH | | | CONCRETE IN THE FRONT SETBACK.NEED TO | | | MEET THE REQUIREMENT OF 1000SQ FT OR | | | 75% ON LANDSCAPE IN THE FIRST 25FT FRONT | | | SETBACK.CALLED CONTR. |
|
|