| 2004-04-05 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04030451 |
| | ADD: 2810 S DIXIE |
| | CONT: ALEXANDER KING CONST |
| | TEL: (561)441-2388 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) STRUCTURAL COMPONENTS- WOOD CONNECT |
| | ORS, CONCRETE ANCHORS |
| | ************IMPORTANT***************** |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | MISSING FLORIDA APPROVAL ON VARIOUS |
| | PRODUCT REPORTS, WILL REQUIRE LOCAL |
| | APPROVAL, FORM ATTACHED.SEE RULE 9B-72. |
| | |
| | 2) PLANS CALL FOR HUGHES ANCHORS. HUGHES |
| | WAS BOUGHT OUT IN 1999. THERE IS NO |
| | FLORIDA LISTING FOR HUGHES UNDER THE FL |
| | PRODUCT APPROVAL SYSTEM. SUBMIT ANOTHER |
| | MANUFACTORER. |
| | |
| | 3) SHEET A-5 SECTION# 1, INDICATES THE |
| | USE OF 5/8" CDX PLYWOOD ON THE FRONT |
| | PORTICO WALL, "FIRE DISTRICT" DOESN'T |
| | ALLOW TYPE VI CONSTRUCTION(WOOD) ON |
| | EXTERIOR WALLS, (VERTICAL SURFACES). |
| | SEE F102.1. |
| | |
| | 4) THE SAME DETAIL SHOWS A MOLD LOCATED |
| | AT THE TOP OF THE PARAPET, BUT NO |
| | MENTION OF WHAT TYPE OF MATERIALS THAT |
| | ARE TO BE USED? F102.7 ARCHITECTURAL |
| | TRIM ON BUILDINGS LOCATED IN THE FIRE |
| | DISTRICT SHALL BE CONSTRUCTED OF APPROV- |
| | ED NONCOMBUSTIBLE MATERIAL OR FIRE |
| | ETARDANT TREATED WOOD. |
| | |
| | 5) ROOFING: F102.4 ROOF COVERINGS IN THE |
| | FIRE DISTRICT SHALL CONFORM TO THE |
| | REQUIREMENTS OF A CLASS A OR B ROOF |
| | COVERINS AS DEFINED IN 1505. |
| | |
| | 6)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | PROVIDE THE POSITIVE/ NEGATIVE PRESSURES |
| | AS TO TABLE 1606.2B INTERIOR AND END |
| | ZONES. |
| | |
| | 7) 1606.1.5 MAIN WIND-FORCE RESISTNG |
| | SYSTEM, PROVIDE A ROOF FRAMING PLAN |
| | INDICATING THE VERTICAL, HORIZONTAL & |
| | GRAVITY LOADS TO BE RESISTED. |
| | 1609.4.3 LOAD REDUCTION. |
| | WHEN STRUCTURAL EFFECTS DUE TO TWO OR |
| | MORE LOADS IN COMBINATION WITH DEAD LOAD |
| | ARE INVESTIGATED IN LOAD COMBINATIONS OF |
| | 1609.4.1 OR 1609.4.2, THE COMBINED |
| | EFFECTS DUE TO THE TWO OR LOADS MULTI- |
| | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD |
| | LOADS SHALL NOT BE LESS THAN THE EFFECTS |
| | FROM THE LOAD COMBINATION OF THE DEAD |
| | LOAD PLUS THE LOAD PRODUCING THE LARGEST |
| | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE |
| | CIFIED IN THE MATERIALS SECTIONS OF THIS |
| | CODE OR A REFRENCED STANDARD SHALL NOT |
| | BE USED WITH THESE LOAD COMBINATIONS |
| | EXCEPT THAT A DURATION OF LOAD INCREASE |
| | SHALL BE PERMITTED IN ACCORDANCE WITH |
| | CHAPTER 23. |
| | |
| | 8) 1707.3.1 JOIST HANGERS, FRAMING |
| | ANCHORS & SIMILAR DEVICES SHALL BE TEST- |
| | ED IN ACCORDANCE W/ ASTM D 1761 & BE |
| | LABELED AND LISTED FOR THEIR LOAD CARRY- |
| | ING CAPACITY. |
| | |
| | 9) PROVIDE A WINDOW AND DOOR BUCK DETAIL |
| | 1707.4.4.2 TAPERED BUCKS: |
| | SHALL EXTEND BEYOND THE INTERIOR FACE |
| | OF THE WINDOW OR DOOR FRAME SUCH THAT |
| | FULL SUPPORT OF THE FRAME IS SUPPORTED. |
| | |
| | 10) PROVIDE THE MINIMUM DESIGN TYPE THIS |
| | BUILDING IS DESIGNED TO TYPE IV OR V? |
| | SEE TABLE 600 3'-10' REQUIRE: |
| | TYPE IV1HR |
| | TYPE V2HR |
| | |
| | 11) 705.1.1.2. OPENINGS LESS THAN 15'-0" |
| | REQUIRE OPENING PROTECTIVES, PROVIDE |
| | 45 MINUTE PROTECTIVES FOR REAR DOORS. |
| | |
| | 12) 1503.4.1 GUTTERS AND LEADERS PLACED |
| | ON THE OUTSIDE OF BUILDINGS SHALL BE |
| | NONCOMBUSTIBLE MATERIAL OR A MINIMUM OF |
| | SCHEDULE 40 PLASTIC PIPE. |
| | |
| | 13)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |