| Plan Review Stops For Permit 04030414 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-20 |
Time |
09:01 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2004-04-20 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2004-04-20 00:00:00 | BUILDING REVISION# 1- OKJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-08 |
Time |
16:25 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-04-08 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-03 |
Time |
13:16 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2004-04-03 |
Time |
13:15 |
Sent To |
PC |
|
| Notes |
| 2004-04-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04030414 | | | ADD: 201 NARCISSUS AV# 902 | | | CONT:PLAN REVIEW O/B KORMAN, HARVEY | | | TEL: (561)804-6655 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE INFO ON THE NEW FIRE RATED | | | ENTRY DOOR AND JAMB. | | | | | | 3) THE FRONT DOOR IS CONSIDERED COMMON | | | AREA NOT PART OF WHAT A O/B OR DRYWALL | | | CONTRACTOR IS LICENSED UNDER, OUT OF | | | SCOPE OF LICENSURE. | | | | | | 4) PROVIDE A DETAIL FOR SOFFITS WITH | | | SPACING OF STUDS, HOW VERTICAL FRAMING | | | MEMBERS ARE TO BE SECURED TO THE DECK | | | ABOVE AND TO THE HORIZONTAL FRAMING | | | MEMBERS OF THE SOFFIT. | | | | | | 5) THIS BUILDING IS A TYPE I OR II | | | BUILDING, ALL FRAMING AND BACKING TO | | | BE FIRE RETARDANT TREATED WOOD 609.2.1. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-13 |
Time |
09:31 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-13 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2004-04-13 00:00:00 | O/B SHOULD NOT BE ISSUED UNTIL CO OF | | | BLDG FROM SUFFOLK CONST. PER FS 489 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-26 |
Time |
09:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-26 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2004-03-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE THE WATTAGE OF THE | | | LUMINAIRES BEING ADDED (INDIVIDUALLY). | | | | | | 2} PLEASE SHOW ADDED LOADS, RECALCULATE | | | TO SHOW EXISTING AND ADDED LOAD TOTALS. | | | SEE 220.3(B)(4) FOR RECESSED LUMINAIRES. | | | | | | 3} PLEASE VERIFY WHETHER THE FIXTURES ON | | | CIRCUIT #34, SHEET E-01, ARE EXISTING, | | | OR BEING ADDED. | | | | | | 4} SEE PLUMBING REVIEW COMMENT REGARDING | | | ARCHITECTS SIGNATURE AND FIRM NUMBER. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-08 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-08 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-09 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-09 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | 1) PLANS DO NOT ILLUSTRATE THE REQUIRED | | | SMOKE DETECTORS LOCATED WITHIN THE | | | UNITS. | | | | | | 2) THE BUILDING HAS NOT RECEIVED A | | | CERTIFICATE OF OCCUPANCY YET. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-08 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-04-08 00:00:00 | TO COMM BD# |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-09 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-09 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | TO COMM BD#23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-04-13 |
Time |
08:30 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-04-13 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-04-09 |
Time |
14:57 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-04-09 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2004-04-09 00:00:00 | PLAN DENIED | | | 1) PLANS ARE NOT SEALED BY ARCHITEC | | | 2) REFER TO SECTION 601.4 BALANCED | | | RETURN AIR | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-02 |
Time |
08:09 |
Rev Time |
0.35 |
| Received By |
hmoser |
Date |
2004-04-02 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2004-04-02 00:00:00 | DENIED: | | | PLEASE PROVIDE ADDITIONAL INFORMATION | | | AS TO WHICH DUCTS ARE TO BE EXTENDED. | | | INDICATE ANY CHANGES IN DUCT SIZE OR | | | DIFFUSERS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-04-13 |
Time |
08:27 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-04-13 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-22 |
Time |
08:23 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-22 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SANITARY AND WATER RISER DIAGRAM ARE | | | REQUIRED PER SECTION 104.3.1.1 | | | 2) SIGNATURE REQUIRED ON SEAL PER FAC | | | 61G1-16.003 & FS 481.2055 - INITIALS ARE | | | NOT ACCEPTABLE. MINIMUM FIRS & LAST NAME | | | AS SHOWN ON ARCHITECT'S LICENSE. | | | 3) CERTIFICATE OF AUTHORIZATION REQUIRED | | | ON TITLE BLOCK PER FS 481.219 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|