Plan Review Details - Permit 04030365
Plan Review Stops For Permit 04030365
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-09-17 Cont ID  
Sent By alange Date 2004-09-17 Time 11:15 Rev Time 0.75
Received By alange Date 2004-09-17 Time 11:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-09-17 Cont ID  
Sent By alange Date 2004-09-17 Time 07:52 Rev Time 0.66
Received By alange Date 2004-09-17 Time 07:52 Sent To  
Notes
2004-09-17 00:00:00DENIED
  
 COMMENTS FROM LAST REVIEW:
 5.PROVIDE 2 COPIES OF SIGNED ENERGY
 CALCS.
  
 6.SHOW BUCK DETAIL COMPLYING WITH
 FBC 1707.4.4.2
  
 7.TWO COPIES OF NOA PRODUCT APPROVALS
 MISSING FOR THERM-TRU SLIDING DOOR.
  
 9.SHOW ON A SITE PLAN LOCATION OF ROOM
 ADDITION AND LOCATION OF OTHER BUILDING
 ON PROPERTY. SHOW ON AN EVEVATION THE
 OPENINGS OF EACH BUILDING SO THAT TABLE
 600 ISSUES CAN BE CALCULATED.
  
 10.SHOW METHOD OF ATTACHMENT FROM NEW
 SLAB TO EXISTING.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-23 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 07:45 Rev Time 2.00
Received By alange Date 2004-03-23 Time 10:11 Sent To  
Notes
2004-03-23 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT
 WILLREJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.SHOW DETAILS.
  
 4.1608.2.3 THE GUARDRAIL SYSTEM
 SHALLBE DESIGNED AND CONSTRUCTED TO
 RESIST A 200 LB CONCENTRATED HORIZONTAL
 LOAD
 APPLIED ON A 1 SQ FT AREA AT ANY POINT
 IN THE SYSTEM INCLUDING INTERMEDIATE
 RAILS OR OTHER ELEMENTS SERVING THIS
 PURPOSE.SUBMIT DETAILED INFORMATION ON
 GUARD RAILS.
  
 5. FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 6.WINDOW BUCKS SHALL COMPLY WITH
 FBC 1707.4.4.2 BUCKS SHALL EXTEND BEYOND
 THE INTERIOR FACE OF THE WINDOW SUCH
 THAT FULL SUPPORT OF THE FRAME IS
 PROVIDED.SHOW DETAIL FOR A FULL
 SUPPORT BUCK.
  
 7.PRODUCT APPROVALS MISSING FOR
 EXTERIOR DOORS AND WINDOWS, IMPACT
 PROTECTION AND ROOFING MATERIALS.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 8.IMPACT PROTECTION REQUIRED.
  
 9.SHOW ON A SITE PLAN LOCATION OF ROOM
 ADDITION AND LOCATION OF ANY OTHER
 BUILDINGS ON PROPERTY INCLUDINGDOOR
 AND WINDOW OPENINGS SO THAT POSSIBLE
 FBC TABLE 600 ISSUES CAN BE CALCULATED.
  
 10.SHOW METHOD OF ATTACHMENT FROM
 NEW SLAB TO EXISTING SLAB.
  
 11.SHOW HEIGHT FROM TUB ON BATHROOM
 WINDOW.
  
 12.RADON FEE DUE $9.00
  
 ANY QUESTIONS CONTACT ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-10 Cont ID  
Sent By csiegber Date 2004-03-09 Time 15:19 Rev Time 0.50
Received By btrobaug Date 2004-03-10 Time 16:41 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 11:03 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 11:03 Sent To M
Notes
2004-08-30 00:00:00TO PK DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-26 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:23 Rev Time 0.00
Received By csiegber Date 2004-08-26 Time 13:50 Sent To Z
Notes
2004-08-26 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-09 Cont ID  
Sent By csiegber Date 2004-03-09 Time 15:19 Rev Time 0.00
Received By csiegber Date 2004-03-09 Time 15:19 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-08 Cont ID  
Sent By mmclean Date 2004-03-09 Time 11:37 Rev Time 0.00
Received By alange Date 2004-09-17 Time 07:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-09-16 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 07:45 Rev Time 0.30
Received By pkrauss Date 2004-09-16 Time 07:35 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-03-22 Cont ID  
Sent By csiegber Date 2004-08-30 Time 11:03 Rev Time 0.33
Received By pkrauss Date 2004-03-22 Time 14:16 Sent To B
Notes
2004-03-22 00:00:00DENIED:
 1.PLEASE PROVIDE ENERGY CALCULATIONS
 PER 2001 FBC CHAPTER 13 SUB-CHAPTER 600.
  
 2.PLEASE INDICATE NEW OR EXISTING
 A/C EQUIPMENT.PROVIDE MODEL, BTU OF
 THE AHU & SEER OF THE CU.
  
 3.PROVIDE PLANS INDICATING DUCT/GRILLE
 SIZE, MATERIAL AND LAYOUT.
  
 PLEASE NOTE, RETURN AIR REQUIRED FROM
 BEDROOM AREAS PER REVISED 2001 FBC(M)
 EFFECTIVE JUNE 30, 2003.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-13 Cont ID  
Sent By btrobaug Date 2004-03-10 Time 17:00 Rev Time 0.25
Received By jleech Date 2004-03-13 Time 14:11 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-08-27 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:23 Rev Time 0.00
Received By mmclean Date 2004-08-27 Time 15:23 Sent To I
Notes
2004-08-27 00:00:00MUST BE A MIN OF 5FT ON SIDE AND 10FT
 IN REAR (10% OF LOT DEPTH).6FT MIN FOR
 BUILDING SEPARATION MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-09 Cont ID  
Sent By csiegber Date 2004-08-26 Time 13:50 Rev Time 0.00
Received By mmclean Date 2004-03-09 Time 11:37 Sent To I
Notes
2004-03-09 00:00:00DENIED, NEED TO SHOW THE LOCATION OF
 ADDITION ON SURVEY WITH SETBACKS