Plan Review Details - Permit 04030308
Plan Review Stops For Permit 04030308
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-05-13 Cont ID  
Sent By rmcdouga Date 2004-05-13 Time 11:16 Rev Time 0.00
Received By rmcdouga Date 2004-05-13 Time 11:16 Sent To  
Notes
2004-05-13 00:00:00REVISED SHEETS 2 AND 3 ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-06 Cont ID  
Sent By csiegber Date 2004-05-13 Time 08:25 Rev Time 0.00
Received By rmcdouga Date 2004-05-06 Time 09:48 Sent To  
Notes
2004-05-06 00:00:00SUBMITTAL FOR COLLIER GARAGE DOOR IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-05 Time 16:48 Rev Time 0.00
Received By rmcdouga Date 2004-05-03 Time 13:40 Sent To  
Notes
2004-05-03 00:00:00BUILDING PROVISO
  
 1) SUBMIT A SIGNED & SEALED INSTALLATION
 REPORT FROM THE ENGINEER FOR THE BUTT
 GLASS WINDOWS.
  
 2) SUBMIT STATE PRODUCT APPROVAL WITH
 APPROVED STATUS FOR THE COLLIER GARAGE
 DOOR AND THE 8'X 7' GARAGE DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-12 Cont ID  
Sent By kstevens Date 2004-04-22 Time 16:31 Rev Time 0.00
Received By rmcdouga Date 2004-04-12 Time 13:48 Sent To  
Notes
2004-04-12 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY THE ATTIC LIVE LOAD ON THE
 PLANS. SEE FBC TABLE 1604.1.
  
 3) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 3/16" TAPCONS IN DETAIL 8 ON SHEET A.
  
 4) SPECIFY A SOLID CORE OR INSULATED
 DOOR BETWEEN THE GARAGE AND CONDITIONED
 SPACE AS REQUIRED BY FBC 13-603.
  
 5) SITE SPECIFIC PRODUCT APPROVAL FOR
 THE BUTT GLASS WINDOW IS INCOMPLETE.
 SPECIFY QUALITY ASSURANCE. SPECIFY THE
 DESIGN PRESSURES. CORRECT THE LOT NUMBER
 LISTED ON SHEET 1 OF 2. SUBMIT THE SPECS
 FOR THE GE 1200 SILICONE. SUBMIT ALL
 CALCULATIONS. THE DIMENSIONS ON THE
 DRAWINGS ARE REQUIRED TO MATCH THOSE ON
 THE ARCHITECTURAL PLANS.
  
 6) SUBMIT LOCAL/STATE PRODUCT APPROVAL
 FOR THE SINGLE OUTSWING DOOR AT BATH #2.
  
 7) SUBMIT STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR WITH APPROVED STATUS
 AND FOR THE 8'X7' OVERHEAD GARAGE DOOR.
  
 MAKE CORRECTIONS REQUIRED BY OTHER
 TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-17 Cont ID  
Sent By btrobaug Date 2004-03-17 Time 12:08 Rev Time 0.50
Received By btrobaug Date 2004-03-17 Time 12:08 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-13 Time 08:25 Rev Time 0.00
Received By csiegber Date 2004-05-13 Time 08:25 Sent To B
Notes
2004-05-13 00:00:00TO RM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-12 Cont ID  
Sent By mmclean Date 2004-05-12 Time 17:55 Rev Time 0.00
Received By csiegber Date 2004-05-12 Time 10:20 Sent To Z
Notes
2004-05-12 00:00:00REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-05-05 Time 16:48 Rev Time 0.00
Received By csiegber Date 2004-05-05 Time 16:48 Sent To B
Notes
2004-05-05 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 12:14 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 12:14 Sent To P
Notes
2004-04-20 00:00:00TO KS BOX/JL REVIEWER/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-12 Cont ID  
Sent By mmclean Date 2004-03-09 Time 11:08 Rev Time 0.00
Received By rmcdouga Date 2004-03-05 Time 15:33 Sent To  
Notes
2004-03-09 00:00:00TO SFD RACK/E
2004-03-05 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-12 Cont ID  
Sent By jleech Date 2004-03-20 Time 08:56 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2004-04-12 00:00:00OK PER P.KRAUSS 3/23/04 RM

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-22 Cont ID  
Sent By kstevens Date 2004-04-22 Time 16:31 Rev Time 0.33
Received By kstevens Date 2004-04-22 Time 16:31 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 12:14 Rev Time 0.33
Received By jleech Date 2004-03-20 Time 08:56 Sent To M
Notes
2004-03-20 00:00:00DENIED;
 SANITARY RISER DIAGRAM DOES NOT MATCH
 FLOOR PLAN.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2004-05-12 Cont ID  
Sent By mmclean Date 2004-05-12 Time 17:55 Rev Time 0.00
Received By mmclean Date 2004-05-12 Time 17:55 Sent To I
Notes
2004-05-12 00:00:00APPROVED REVISION - PATIO

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-09 Cont ID  
Sent By csiegber Date 2004-05-12 Time 10:21 Rev Time 0.00
Received By mmclean Date 2004-03-09 Time 11:08 Sent To I
Notes
***NONE***