Plan Review Details - Permit 04030142
Plan Review Stops For Permit 04030142
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-02-28 Cont ID  
Sent By alange Date 2005-02-28 Time 09:36 Rev Time 0.50
Received By alange Date 2005-02-28 Time 09:36 Sent To  
Notes
2005-02-28 00:00:00REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-02-24 Cont ID  
Sent By alange Date 2005-02-24 Time 14:26 Rev Time 0.50
Received By alange Date 2005-02-24 Time 14:26 Sent To  
Notes
2005-02-24 00:00:00DENIED
  
 SUBMIT PRODUCT APPROVALS WITH QUALITY
 ASSURANCE FOR CASEMENT WINDOWS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING TO BE ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-02-02 Cont ID  
Sent By alange Date 2005-02-02 Time 10:33 Rev Time 0.66
Received By alange Date 2005-02-02 Time 10:33 Sent To Z
Notes
2005-02-02 00:00:00REVISION DENIED
  
 1.SHOW REVISED SQUARE FOOTAGE ON
 PLANS.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 HOW PLANS STAMPED FOR POSSIBLE IMPACT
 FEES.
  
 3.CLEARLY MARK ALL CHANGES ON PLANS.
 IT APPREARS SEVERAL NEW WINDOWS HAVE
 BEEN ADDED.SUBMIT STRUCTURAL DETAILS
 FOR OPENINGS.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-29 Cont ID  
Sent By alange Date 2004-11-29 Time 13:46 Rev Time 1.50
Received By alange Date 2004-11-29 Time 11:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-13 Cont ID  
Sent By pkrauss Date 2004-04-01 Time 09:14 Rev Time 2.66
Received By alange Date 2004-04-13 Time 13:08 Sent To  
Notes
2004-04-13 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED UPON SBCCI BUILDING VALUATION
 DATA, PROJECT VALUATION OF $250.000 IS
 TO LOW AND THE REVISED VALUATION IS
 $297,419.ADDITIONAL PERMIT FEES OF
 $478.93 ARE DUE. SEC. 104.6.5 WEST PALM
 BEACH AMMENDMENTS TO THE FBC.
  
 4.WHAT ROOF TILE ARE YOU USING?
 SPANISH "S" IS ON PLANS AND 2 DIFFERENT
 PRODUCT APPROVALS ARE SUBMITTED.
  
 5.PRODUCT APPROVAL FOR K.D. WINDOWS
 ARE NOT LISTED ON THE DCA PRODUCT
 APPROVAL SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONAN PLEASE SEE THE STATE
 WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.A SEPARATE ROOFING PERMIT IS
 REQUIRED.CONTRACTOR NOT SIGNED ON AT
 TIME OF APPLICATION.
  
 7.PRODUCT APPROVALS FOR GLASS BLOCK
 NOT SUBMITTED WITH PLANS.SUBMIT TWO
 COPIES OF PRODUCT APPROVAL SHOWING
 1 HR PROTECTION.
  
 8.TOTAL GROSS AREA ON PLAN IS NOT
 CORRECT.
  
 9.PAGE A-2 CHECK NOTES...DO YOU MEAN
 FBC AND NOT FBD?PLEASE CLARIFY.
  
 10.GENERAL ARCH. NOTES #8 ALL WINDOWS
 ARE TO BE IMPACT RESISTANT.PLEASE
 REVISE.IMPACT PROTECT IS CALLED OUT IN
 OTHER LOCATIONS.
  
 ANY QUESTIONS CALL ME
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-10 Cont ID  
Sent By btrobaug Date 2005-08-10 Time 10:14 Rev Time 0.50
Received By btrobaug Date 2005-08-10 Time 10:07 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-09 Cont ID  
Sent By btrobaug Date 2004-11-09 Time 11:56 Rev Time 0.50
Received By btrobaug Date 2004-11-09 Time 11:44 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-26 Cont ID  
Sent By jleech Date 2004-03-20 Time 11:58 Rev Time 0.45
Received By btrobaug Date 2004-03-25 Time 09:09 Sent To M
Notes
2004-03-25 00:00:001)BOTH PANELS LABELED A
  
 2)RISER SHOWS 3/0 AND PANEL SCHEDULE
 SHOWS #3 ?
  
 3)SERVICE LOCATION NOT SHOWN
  
 4)NEED TO CHANGE NOTE #912GA MIN
  
 5)NO OUTLET SHOW FOR CENTRAL VAC AND
 WATER HEATER.

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-09-22 Cont ID  
Sent By adarroug Date 2005-09-22 Time 16:13 Rev Time 0.00
Received By adarroug Date 2005-09-22 Time 16:13 Sent To P
Notes
2005-09-22 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-08-17 Cont ID  
Sent By adarroug Date 2005-08-17 Time 16:13 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 16:13 Sent To P
Notes
2005-08-17 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-08-03 Cont ID  
Sent By adarroug Date 2005-08-03 Time 16:25 Rev Time 0.00
Received By adarroug Date 2005-08-03 Time 16:25 Sent To E
Notes
2005-08-03 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-02-25 Cont ID  
Sent By adarroug Date 2005-02-25 Time 14:46 Rev Time 0.00
Received By adarroug Date 2005-02-25 Time 14:46 Sent To B
Notes
2005-02-25 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-02-11 Cont ID  
Sent By adarroug Date 2005-02-11 Time 10:41 Rev Time 0.00
Received By adarroug Date 2005-02-11 Time 10:40 Sent To B
Notes
2005-02-07 00:00:00TO ALANGE DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-01-28 Cont ID  
Sent By mjacobs Date 2005-01-28 Time 14:36 Rev Time 0.00
Received By mjacobs Date 2005-01-28 Time 14:36 Sent To B
Notes
2005-01-28 00:00:00TO "AL" DESK/REV..

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 13:34 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 13:34 Sent To P
Notes
2004-12-14 00:00:00SENT TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-01 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 14:36 Rev Time 0.00
Received By mjacobs Date 2004-12-01 Time 14:36 Sent To P
Notes
2004-12-01 00:00:00SENT TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-05 Cont ID  
Sent By csiegber Date 2004-11-05 Time 13:29 Rev Time 0.00
Received By csiegber Date 2004-11-05 Time 13:29 Sent To E
Notes
2004-11-05 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-13 Cont ID  
Sent By mmclean Date 2004-03-12 Time 14:49 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:35 Sent To  
Notes
2004-03-16 00:00:00TO SFD RACK/E
2004-03-11 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-11-23 Cont ID  
Sent By prafter Date 2004-11-23 Time 07:47 Rev Time 0.45
Received By prafter Date 2004-11-23 Time 07:46 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By btrobaug Date 2004-03-26 Time 06:11 Rev Time 0.30
Received By pkrauss Date 2004-04-01 Time 08:46 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2005-10-06 Cont ID  
Sent By jleech Date 2005-10-06 Time 08:13 Rev Time 0.33
Received By jleech Date 2005-10-06 Time 08:13 Sent To  
Notes
2005-10-06 00:00:00REVISED RISER DIAGRAM OK

Review Stop P PLUMBING
Rev No 5 Status F Date 2005-08-23 Cont ID  
Sent By jleech Date 2005-08-23 Time 13:45 Rev Time 0.75
Received By jleech Date 2005-08-23 Time 13:40 Sent To  
Notes
2005-08-23 00:00:00DENIED;
 1.ADD CLEANOUT ON W/M STACK 4' AFF.
 2.FIXTURES MISSING FROM RISER DIAGRAM;
 1-BAR SINK OR VEG SINK, BIDET, W/C AND
 1-LAV.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-12-29 Cont ID  
Sent By kstevens Date 2004-12-29 Time 10:38 Rev Time 0.60
Received By kstevens Date 2004-12-29 Time 10:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-12-13 Cont ID  
Sent By kstevens Date 2004-12-13 Time 11:08 Rev Time 0.50
Received By kstevens Date 2004-12-13 Time 11:08 Sent To  
Notes
2004-12-13 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) SHT P-1 HAND DRAWN CHANGES TO A
 SIGNED AND SEALED SET OF PLANS IS NOT
 APPROVED. SECTION 104.2.1.3.
 2) SHT P-2 HAND DRAWN CHANGES TO A
 SIGNED AND SEALED SET OF PLANS IS NOT
 APPROVED. SECTION 104.2.1.3.
  
 SUBMIT NEW P-1 AND P-2 SHEETS WITH ALL
 CORRECTIONS SIGNED, SEALED & DATED FOR
 REVIEW. SECTION 104.2.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-24 Cont ID  
Sent By kstevens Date 2004-11-24 Time 06:21 Rev Time 0.33
Received By kstevens Date 2004-11-24 Time 06:21 Sent To B1
Notes
2004-11-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) LAUNDRY SINK IS NOT VENTED. SECTION
 902.1
 B) WASH MACHINE REQUIRES A STANDPIPE
 AND A CLEANOUT 4 FT ABOVE THE FLOOR FOR
 ACCESS. SECTIONS 708.10 & 1002.1
 C) MASTER BATH TUB, SHOWER & BIDET ALL
 REQUIRE A TRAP. SECTION 1002.1
 D) SHOWER IN BATH #3 REQUIRES A TRAP.
 SECTION 1002.1
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-20 Cont ID  
Sent By jleech Date 2004-03-20 Time 11:58 Rev Time 0.33
Received By jleech Date 2004-03-20 Time 11:58 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-02-04 Cont ID  
Sent By mmclean Date 2005-02-04 Time 16:27 Rev Time 0.00
Received By mmclean Date 2005-02-04 Time 16:27 Sent To I
Notes
2005-02-04 00:00:00APPROVING BUILDING LAYOUT CHANGE

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-12 Cont ID  
Sent By mmclean Date 2004-03-12 Time 14:49 Rev Time 0.00
Received By mmclean Date 2004-03-12 Time 14:49 Sent To I
Notes
2004-03-12 00:00:00MUST BE 3FT 1IN ON SIDE