| Plan Review Stops For Permit 04030142 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-28 |
Time |
09:36 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-02-28 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-24 |
Time |
14:26 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-02-24 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | DENIED | | | | | | SUBMIT PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE FOR CASEMENT WINDOWS. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-02 |
Time |
10:33 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-02-02 |
Time |
10:33 |
Sent To |
Z |
|
| Notes |
| 2005-02-02 00:00:00 | REVISION DENIED | | | | | | 1.SHOW REVISED SQUARE FOOTAGE ON | | | PLANS. | | | | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | HOW PLANS STAMPED FOR POSSIBLE IMPACT | | | FEES. | | | | | | 3.CLEARLY MARK ALL CHANGES ON PLANS. | | | IT APPREARS SEVERAL NEW WINDOWS HAVE | | | BEEN ADDED.SUBMIT STRUCTURAL DETAILS | | | FOR OPENINGS. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-11-29 |
Time |
13:46 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2004-11-29 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-01 |
Time |
09:14 |
Rev Time |
2.66 |
| Received By |
alange |
Date |
2004-04-13 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2004-04-13 00:00:00 | DENIED | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED UPON SBCCI BUILDING VALUATION | | | DATA, PROJECT VALUATION OF $250.000 IS | | | TO LOW AND THE REVISED VALUATION IS | | | $297,419.ADDITIONAL PERMIT FEES OF | | | $478.93 ARE DUE. SEC. 104.6.5 WEST PALM | | | BEACH AMMENDMENTS TO THE FBC. | | | | | | 4.WHAT ROOF TILE ARE YOU USING? | | | SPANISH "S" IS ON PLANS AND 2 DIFFERENT | | | PRODUCT APPROVALS ARE SUBMITTED. | | | | | | 5.PRODUCT APPROVAL FOR K.D. WINDOWS | | | ARE NOT LISTED ON THE DCA PRODUCT | | | APPROVAL SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONAN PLEASE SEE THE STATE | | | WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6.A SEPARATE ROOFING PERMIT IS | | | REQUIRED.CONTRACTOR NOT SIGNED ON AT | | | TIME OF APPLICATION. | | | | | | 7.PRODUCT APPROVALS FOR GLASS BLOCK | | | NOT SUBMITTED WITH PLANS.SUBMIT TWO | | | COPIES OF PRODUCT APPROVAL SHOWING | | | 1 HR PROTECTION. | | | | | | 8.TOTAL GROSS AREA ON PLAN IS NOT | | | CORRECT. | | | | | | 9.PAGE A-2 CHECK NOTES...DO YOU MEAN | | | FBC AND NOT FBD?PLEASE CLARIFY. | | | | | | 10.GENERAL ARCH. NOTES #8 ALL WINDOWS | | | ARE TO BE IMPACT RESISTANT.PLEASE | | | REVISE.IMPACT PROTECT IS CALLED OUT IN | | | OTHER LOCATIONS. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-10 |
Time |
10:14 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-10 |
Time |
10:07 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-11-09 |
Time |
11:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-11-09 |
Time |
11:44 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-20 |
Time |
11:58 |
Rev Time |
0.45 |
| Received By |
btrobaug |
Date |
2004-03-25 |
Time |
09:09 |
Sent To |
M |
|
| Notes |
| 2004-03-25 00:00:00 | 1)BOTH PANELS LABELED A | | | | | | 2)RISER SHOWS 3/0 AND PANEL SCHEDULE | | | SHOWS #3 ? | | | | | | 3)SERVICE LOCATION NOT SHOWN | | | | | | 4)NEED TO CHANGE NOTE #912GA MIN | | | | | | 5)NO OUTLET SHOW FOR CENTRAL VAC AND | | | WATER HEATER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-22 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-22 |
Time |
16:13 |
Sent To |
P |
|
| Notes |
| 2005-09-22 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-17 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
16:13 |
Sent To |
P |
|
| Notes |
| 2005-08-17 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-03 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
16:25 |
Sent To |
E |
|
| Notes |
| 2005-08-03 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2005-02-25 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-11 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-11 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2005-02-07 00:00:00 | TO ALANGE DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-28 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-28 |
Time |
14:36 |
Sent To |
B |
|
| Notes |
| 2005-01-28 00:00:00 | TO "AL" DESK/REV.. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
13:34 |
Sent To |
P |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-01 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-01 |
Time |
14:36 |
Sent To |
P |
|
| Notes |
| 2004-12-01 00:00:00 | SENT TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
13:29 |
Sent To |
E |
|
| Notes |
| 2004-11-05 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2004-03-16 00:00:00 | TO SFD RACK/E | | 2004-03-11 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2004-11-23 |
Time |
07:47 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2004-11-23 |
Time |
07:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-26 |
Time |
06:11 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-01 |
Time |
08:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-06 |
Time |
08:13 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-10-06 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | REVISED RISER DIAGRAM OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-23 |
Time |
13:45 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-08-23 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2005-08-23 00:00:00 | DENIED; | | | 1.ADD CLEANOUT ON W/M STACK 4' AFF. | | | 2.FIXTURES MISSING FROM RISER DIAGRAM; | | | 1-BAR SINK OR VEG SINK, BIDET, W/C AND | | | 1-LAV. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-29 |
Time |
10:38 |
Rev Time |
0.60 |
| Received By |
kstevens |
Date |
2004-12-29 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-13 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-12-13 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2004-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) SHT P-1 HAND DRAWN CHANGES TO A | | | SIGNED AND SEALED SET OF PLANS IS NOT | | | APPROVED. SECTION 104.2.1.3. | | | 2) SHT P-2 HAND DRAWN CHANGES TO A | | | SIGNED AND SEALED SET OF PLANS IS NOT | | | APPROVED. SECTION 104.2.1.3. | | | | | | SUBMIT NEW P-1 AND P-2 SHEETS WITH ALL | | | CORRECTIONS SIGNED, SEALED & DATED FOR | | | REVIEW. SECTION 104.2.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-24 |
Time |
06:21 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-24 |
Time |
06:21 |
Sent To |
B1 |
|
| Notes |
| 2004-11-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-2 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) LAUNDRY SINK IS NOT VENTED. SECTION | | | 902.1 | | | B) WASH MACHINE REQUIRES A STANDPIPE | | | AND A CLEANOUT 4 FT ABOVE THE FLOOR FOR | | | ACCESS. SECTIONS 708.10 & 1002.1 | | | C) MASTER BATH TUB, SHOWER & BIDET ALL | | | REQUIRE A TRAP. SECTION 1002.1 | | | D) SHOWER IN BATH #3 REQUIRES A TRAP. | | | SECTION 1002.1 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-20 |
Time |
11:58 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-03-20 |
Time |
11:58 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-04 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-04 |
Time |
16:27 |
Sent To |
I |
|
| Notes |
| 2005-02-04 00:00:00 | APPROVING BUILDING LAYOUT CHANGE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-12 |
Time |
14:49 |
Sent To |
I |
|
| Notes |
| 2004-03-12 00:00:00 | MUST BE 3FT 1IN ON SIDE |
|
|